The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65
Accuracy: Basic Type, Size: 32, Motor Mounting: Top Mounting Position, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: B [LEY25, 6mm; LEY32, 8(10)mm], Stroke: 350mm, Motor Option: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: A (10m), Driver: A1 (LECSA1-S, 100~120V, Incremental, Pulse
Accuracy: Basic Type, Size: 32, Motor Mounting: Top Mounting Position, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: C [LEY25, 3mm; LEY32, 4(5)mm], Stroke: 350mm, Motor Option: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: A (10m), Driver: A1 (LECSA1-S, 100~120V, Incremental,
Accuracy: Basic Type, Size: 32, Motor Mounting: Top Mounting Position, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: C [LEY25, 3mm; LEY32, 4(5)mm], Stroke: 350mm, Motor Option: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: A (10m), Driver: A1 (LECSA1-S, 100~120V, Incremental, Pulse
Accuracy: Basic Type, Size: 32, Motor Mounting: Top Mounting Position, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: A [LEY25, 12mm; LEY32, 16(20)mm], Stroke: 500mm, Motor Option: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: A (10m), Driver: A1 (LECSA1-S, 100~120V, Incremental
Accuracy: Basic Type, Size: 25, Motor Mounting: Top Mounting Position, Motor Type: S2 [AC Servo Motor, (Incremental Encoder), Output 100W], Lead: A [LEY25, 12mm; LEY32, 16(20)mm], Stroke: 400mm, Motor Option: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: L (Foot), Cable Type: S (Standard Cable), Cable Length: A (10m), Driver: A1 (LECSA1-S, 100~120V
Accuracy: Basic Type, Size: 32, Motor Mounting: Top Mounting Position, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: A [LEY25, 12mm; LEY32, 16(20)mm], Stroke: 100mm, Motor Option: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: A (10m), Driver: A1 (LECSA1
Accuracy: Basic Type, Size: 32, Motor Mounting: Top Mounting Position, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: B [LEY25, 6mm; LEY32, 8(10)mm], Stroke: 350mm, Motor Option: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Cable Type: Standard Cable, Cable Length: 10m, Driver: LECSA1-S, 100~120V, Incremental, Pulse Input,
Accuracy: Basic Type, Size: 32, Motor Mounting: Top Mounting Position, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: C [LEY25, 3mm; LEY32, 4(5)mm], Stroke: 350mm, Motor Option: w/Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Cable Type: Standard Cable, Cable Length: 10m, Driver: LECSA1-S, 100~120V, Incremental, Pulse Input, I/O
Accuracy: Basic Type, Size: 32, Motor Mounting: Top Mounting Position, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: C [LEY25, 3mm; LEY32, 4(5)mm], Stroke: 350mm, Motor Option: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Cable Type: Standard Cable, Cable Length: 10m, Driver: LECSA1-S, 100~120V, Incremental, Pulse Input, I
Accuracy: Basic Type, Size: 32, Motor Mounting: Top Mounting Position, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: A [LEY25, 12mm; LEY32, 16(20)mm], Stroke: 500mm, Motor Option: w/Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Cable Type: Standard Cable, Cable Length: 10m, Driver: LECSA1-S, 100~120V, Incremental, Pulse Input,
Accuracy: Basic Type, Size: 25, Motor Mounting: Top Mounting Position, Motor Type: S2 [AC Servo Motor, (Incremental Encoder), Output 100W], Lead: A [LEY25, 12mm; LEY32, 16(20)mm], Stroke: 400mm, Motor Option: w/Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Foot, Cable Type: Standard Cable, Cable Length: 10m, Driver: LECSA1-S, 100~120V, Incremental, Pulse Input
Regulator manifold series ARM is available in standard size 1000 & 2000 and the modular style is available in sizes 2500 & 3000. Standard models are available with 4 connection methods and have backflow function availability. Modular styles can be freely mounted on a manifold station and have easy set up using the new handle.
Regulator manifold series ARM is available in standard size 1000 & 2000 and the modular style is available in sizes 2500 & 3000. Standard models are available with 4 connection methods and have backflow function availability. Modular styles can be freely mounted on a manifold station and have easy set up using the new handle.
Regulator manifold series ARM is available in standard size 1000 & 2000 and the modular style is available in sizes 2500 & 3000. Standard models are available with 4 connection methods and have backflow function availability. Modular styles can be freely mounted on a manifold station and have easy set up using the new handle.
Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 2500 (25 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M
Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 2500 (25 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: F79Z--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 5M
Magnet: D (Built-in), Bore Size: 40 (1 1/2 Inch), Magnetic Holding Force: L (Small Holding Force), Stroke: 2500 (25 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: F7PL--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, 3M
Magnet: D (Built-in), Bore Size: 40 (1 1/2 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 2500 (25 Inch), Adjuster: Adjuster Bolt, Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical, 0.5M, Number: S (1 pc.)
Magnet: D (Built-in), Bore Size: 40 (1 1/2 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 2500 (25 Inch), Adjuster: Adjuster Bolt, Auto Switch: F79--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 0.5M