SMC Corporation of America
Elite Part Number Search
Search Results "KQG2T08-10-F"

Weight calculation m2 = d x e x f x Relative density m2 = 4 x 5 + 6 x 2.7 x 10-6 = 3.24 x 10-4 (kg) Inertial moment around Z2 axis IZ2 = {m2 (d2 x e2) / 12} x 10-6 IZ2 = {3.24 x 10-4 x (42 + 52) / 12} x 10-6 = 1.11 x 10-9 (kg.m2) = 1.11 x 10-9 + 3.24 x 10-4 x 23.52 x 10-6 = 0.18 x 10-6 (kg.m2) Inertial moment around Z axis IB = IZ2 x m2r22 x 10-6 IB Thus, the total inertial moment is I

52.6 [59.6] Approx. 300 (Lead wire length) 64.3 [66.5] 54.5 [56.7] 63.4 56 49.5 R1 P R2 R1 P R2 R1 P R2 10 10 10 10 10 10 28 28 28 14 14 14 5 5 5 28.5 28.5 28.5 35.6 35.6 35.6 Refer to the page 91 for dimentions with connector cable. 8 Series SYJ3000 2 Position Double [ ]: AC G H Grommet (G), (H): SYJ3240-M5 M5 x 0.8 (A, B port) 10 5 10 2-3.2 (For mounting) 22 2.5 Manual override B A 11

override 34.7 [41.7] M5 x 0.8 (A, B port) 2-1.8 (For manifold mounting) (Light/Surge voltage suppressor) 28 [35] + 22.1 54.4 [56.6] 2 13.5 12.6 15 R P R (Bracket) 15 11 10 1.2 (PE port) 22.1 7 7 15 M5 x 0.8 (P, R port) M8 connector (WO): SYJ3120-WO-M3 (-F) L plug connector (L) : SYJ3120-L-M3 (-F) M plug connector (M): SYJ3120-M-M3 (-F) (2) Approx. 300 (Lead wire length) 28 [35] 12.6 32.5

Applicable bore size A D L MM N R W Flat type Round type CJ-CF010 CJ-CR010 10 8 10 13 M4 x 0.7 6 10 8 Part no.

1N X430 03 AR 30 BG F N X425 03 Regulator Regulator For high/low temperature For high pressure 25 30 40 50 60 Body size Body size X430 X440 Low temperature 20 25 30 40 50 60 High temperature Thread type Thread type Rc NPT G Nil N F Rc NPT G Nil N F Port size Port size Body size Port size Body size Symbol Port size 25 30 40 50 60 Symbol 20 25 30 40 50 60 02 03 04 06 10 1/4 01 02 03 04 06 10

kPa ISE20CH1.000 MPa ONOFF ISE20C0.050 MPa ZSE20C5.1 kPa ZSE20CF5.0 kPa ISE20CH0.100 MPa 1.5 ms OUT1 ON OUT1 OFF -30No.PS-OMU0008CN-D [F 2] OUT2 36 [F 1] OUT1 [F 3] 38 0 ms [F 4] 39 [F 5] FUNC 41 [F 6] 43 0% [F10] 44 std() [F11] 50 1000 [F80] 51 OFF [F81] 52 OFF [F82] 54 A [F90] 55 OFF [F96] 57 [F97] 58 OFF [F98] 60 () [F99] 62 OFF XY "---" -31No.PS-OMU0008CN-D [F 0]

A A F F A F MX L L L L = 100 mm 8 L = 100 mm 8 MTS MXP8-10 MXP8-10 MXP8-20 MXP8-20 MXP8-10 MXP8-20 8 L = 100 mm 0.03 0.04 MY 0.06 Table displacement (mm) Table displacement (mm) Table displacement (mm) MXP8-10 MXP8-10 MXP8-20 MXP8-20 MXP8-10 MXP8-20 0.05 MXP8-10 MXP8-10 MXP8-20 MXP8-20 MXP8-10 MXP8-20 0.03 CY 0.02 0.04 0.02 0.03 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South

Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V -5..5 V -20..20 mA 0..10 V 2 Analogue input range Sets the analogue input device range. Selects the analogue input range. -10..10 V Channel 0..5 V 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.

Switch bracket Auto switch b Switch holder d Auto switch mounting screw c Auto switch mounting band D-X Technical Data 375 CG3 Series Operating Range (mm) Auto switch model Bore size 20 25 32 40 50 63 80 100 D-M9(V) D-M9W(V) D-M9A(V) 4.5 5.0 4.5 5.5 5.0 5.5 D-A9 7 6 8 8 8 9 D-C7/C80 D-C73C/C80C D-B5/B64 D-B59W D-H7/H7W D-H7NF/H7BA 9 8 10 10 10 11 8 10 9 10 10 11 11 11 13 13 14 14 14

10 15 15 20 MS4-10 MS5-10 MS6-15 MS6-15 MS8-20 Left Right Left Right Operating direction of the housing Operating direction of the housing Manufactured by Misumi Trading Ltd.

70 0.01 2 40 6000 100 40 0.1 3 90 1000 20 1 4 10 +3 5 5 10 +7 6 0 < Cp 5 +10 7 5 < Cp 10 Cw 0.5 8 0.5 < Cw 5 9 5 < Cw 10 x Cp > 10 Cw > 10 > 5 [How to Perform a Test to Check the Performance] ISO 12500, which sets out the test method to be used in order to check the filter performance for each of the three kinds of contaminants, is indicated below.

Body size C With bowl guard AF20 Port size M5 1/8 1/4 3/8 1/2 3/4 1 AF10 to 60 Symbol 10 20 30 40 50 60 Note 5) Drain guide 1/4 AF30 to 60 N Note 1) Float type Note 4) auto drain (N.O.) M5 01 02 03 04 06 10 D AF30 to 60 Flow direction: Right to left AF10 to 60 F Note 2) Note 3) Bracket is not assembled and is supplied loose at the time of shipment.

C Y Y B G A 90 B 90 B G A D Note 1) 90 G A H X X X D Note 1) D Note 1) B B B F E F F E A H A G G RG RT RS B 296 305 C R310 R445 D 93 129 E 60 87 F 10 15 G 6 7 B 296 309 C R390 R495 D 93 129 E 60 87 F 10 15 G 6 7 B 299 307 C R350 R440 D 93 129 F 10 15 G 6 7 H 610 700 A 600 743 A 680 797 A 643 740 15 32 15 32 15 32 Y Note 2) Y Note 2) Y Note 2) X 558 to 573 685 to 708 X 518 to 533 558 to 581

8 15 13 3.5 1.5 5.5 200 200 10 107.0 108.0 107.5 108.0 154 164 12.5 10.5 17.5 15.5 6 4 8 D-Y7/Z80 D-Y59/Y69/Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL Operating Range Auto switch model Bore size (mm) 125 140 160 180 200 D-Z7/Z80 14.5 14 13 14 14.5 Hs D-A3/A44 D-A5/A6 A 10 10 10 10 10 D-A59W Ht 17 17 17 17 17 D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV 8 7.5 7 12 13 D-Y7BAL 7 7 7 6 6 B D-F5/J5

11 14 20 20 16 19 24 34 34 40 50 64 80 80 10 10 14 22 22 14 14 20 30 30 28 28 40 60 60 10 10 14 22 22 14 14 20 30 30 12.5 16.5 23.5 23.5 Bracket Combinations Bracket combination table -Refer to table together with combination drawings.

Internal Holding Force External Holding Force MHKL2-12C MHKL2-12S 20 15 Holding force (N) Holding force (N) Pressure 0.6MPa 15 Pressure 0.6MPa 10 0.5MPa 0.5MPa 10 F F 0.4MPa 0.4MPa 5 5 0.3MPa 0.3MPa Note) In case of single acting type, the value is for stroke center. 0 0 10 20 30 40 50 10 20 30 40 50 10 20 30 40 50 Holding point L(mm) Holding point L(mm) MHKL2-16S MHKL2-16C External hold

F . Bponse time 1.zms .LeadwiE Oil pr@f vinyl, 63.4, 0.008 in.'? 2 wne (Red Black),20 inx . lmpacl rAislance " 30G . tNularion Esistance 50m or more under the lest voltag 500VDC (BeMen case and cable) . Wirhsland vohaSe 1500VAC 1 min (BeMeen .6e and cabls) . Amb enl lenpralur 10 60'C 04'l4O"F) . Prol*lion slruciure.

F . Bponse time 1.zms .LeadwiE Oil pr@f vinyl, 63.4, 0.008 in.'? 2 wne (Red Black),20 inx . lmpacl rAislance " 30G . tNularion Esistance 50m or more under the lest voltag 500VDC (BeMen case and cable) . Wirhsland vohaSe 1500VAC 1 min (BeMeen .6e and cabls) . Amb enl lenpralur 10 60'C 04'l4O"F) . Prol*lion slruciure.

thread NC E E NA B WH 10 FT H2 10 A K F N JC JD N S + Stroke F H ZZ + Stroke (mm) H1 GB GA FZ FW FY FX FT FD F E D C B A Bore size (mm) Stroke range (mm) Effective thread length 5 47.5 53.5 68 38 21 51 6 7 16 14.5 10 40.5 32 18 15.5 200 to 700 20 6 49.5 56.5 70 44 27 53 9 7 16 18 12 45.5 36 22 19.5 200 to 700 25 6 51.5 55 72 50 33 55 9 7 19 18 12 51.5 44 22 19.5 200 to 1000 32 8 51.5 56

C 4FD A K BN F GF GB Width across flats B1 Cushion valve 4-J MM H1 Q D E B V FB FY FT N FX FZ Width across flats ZZ + Stroke (mm) Width across flats 10 Effective thread length (mm) Bore size (mm) Stroke range (mm) BP A B1 H1 BN C D Ee11 F FT FX FY FZ GA GB GC GD FB B FD 32 1/8 22 17 6 97 32.5 12 30 13 10 72 38 87 83 13 45.5 13 56 54 to 500 7 19.5 40 1/8 30 22 8 104 38 16 35 13 10 83 46