*Lead wire length symbols 0.5m Nil (Example) M9NW 1m M (Example) M9NWM 3m L (Example) M9NWL 5m Z (Example) M9NWZ *Auto switches matked with a "" are produced upon receipt of orders. *Auto switches are shipped together, (but not assembled). -18- Specifications Table 1.

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Solid state auto switches marked "" are produced upon receipt of order. You do not need to specify "N" (i.e., without lead wire) for D-A3, D-A44, D-G39, and D-K39.

D-A9V/M9V/M9WV/M9A(V)L types cannot be mounted. Do not indicate suffix N for no lead wire on D-A3/A44/G39/K39 models. (Example) M9NW (Example) M9NWM (Example) M9NWL (Example) M9NWZ (Example) H7CN Since there are other applicable auto switches than listed, refer to page 1040 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785.

D-A9V/M9V/M9WV/D-M9A(V)L types cannot be mounted. Do not indicate suffix N for no lead wire on D-A3/A44/G39/K39 models. -X Lead wire length symbols: 0.5 mNil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Individual -X Since there are other applicable auto switches than listed, refer to page 1214 for details.

*Lead wire length symbols 0.5m Nil 1m M 3m L 5m Z *Auto switches matked with a "" are produced upon receipt of orders. *Refer to catalog for the details of solid state auto switch with pre-wired connector. *Auto switches are shipped together, (but not assembled).

Lead wire length symbols: 0.5 m Nil (Example) A53 3 m L (Example) A53L 5 m Z (Example) A53Z Auto Switch Mounting Bracket Part No.

S 192 193 195 201.5 LS 232 233 241 LT 5.5 5.5 6 6 Rc(PT)P 1/4 1/4 3/8 3/8 X 20 20 23 25 N 22 27 27 30 5.8 to 8.8 251.5 6.8 to 11.3 4.10-8 High Power Cylinder Series RHC 20, 25, 32, 40 How to Order RHC B 20 High power cylinder High power cylinder Cylinder stroke Number of auto switches *Refer to the stroke table on p.4.10-5. 2 1 n S n Mounting Basic Axial foot Front flange Rear flange B L

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -

How-to-Order L E C T 1 E G S Electri Enable switch*1 actuator Nil Without enable switch Controller relatio S With enable switch Teaching Box With stop switch Initial displayed language*2 E English*2 J Japanese*2 Cable length 3m *1 When a teaching box with enable switch is selected, it is necessary to activate the enable switch to change the default parameter setting of the controller..

L E C T 1 3 J G S 1 S 1 2 J 2 E 2 3m 1 6.43 2 6.3 9 TB 12 - 3. 3.1 (1) TB Ver.5.11 TB Ver2.1LECPA No.0 1 LECPA TB Ver2.1LECPA No. 1 ) TB Ver1.** TB Ver2.**/ / (2)Tree TB Ver.5.11 MENU Data No. 2 Data Monitor JOG Test Alarm Setting Ver1.** Ver2.** 12 TB Ver2.1*LECPANo.0 Monitor No. 2 JOG Test 1 LECPATB Ver2.1*LECPA Alarm Setting Ver1.