[mg/L] 70 or less 200 or less Calcium hardness [mg/L] 50 or less 150 or less Ion silica [mg/L] 30 or less 50 or less Iron [mg/L] 0.3 or less 1.0 or less Copper [mg/L] 0.1 or less 0.3 or less Sulfide ion [mg/L] Not detected Not detected Referential Ammonium ion [mg/L] 0.1 or less 1.0 or less item Residual chlorine [mg/L] 0.3 or less 0.3 or less Separation carbonic acid [mg/L] 4.0 or less
For example, changing from F Kit (D-sub connector) to S Kit (serial transmission) is achieved by simply changing the kit piece. 19 20 19 20 19 20 19 20 19 20 19 20 19 20 19 20 COM Station 1 Double wiring Station 2 Single wiring Station 3 Double wiring Station 4 Single wiring (Refer to the connector wiring diagram) Printed circuit board patterns between connectors are shifted at every station
Spacer with bracket (YT-D) Spacer (Y-D) Connecting Spacer for Modular Type F.R.L. Unit Series AV2000-A AV3000-A AV4000-A AV5000-A Spacer Y200-D Y300-D Y400-D Y600-D Spacer with bracket Y200T-D Y300T-D Y400T-D Y600T-D Applicable model AC20-D AC30-D AC40-D * AC50-D AC60-D * Except port size 06. Note) AV-A series can be connected to AC-A, B series.
Model Option AR20(K)-B AR25(K)-B AR30(K)-B AR40(K)-B AR40(K)-06-B AR50(K)-B AR60(K)-B Bracket assembly *1 AR23P-270AS AR28P-270AS AR33P-270AS AR43P-270AS AR52P-270AS Set nut AR23P-260S AR28P-260S AR33P-260S AR43P-260S *2 Round type *3 Standard G36-10-01 G46-10-01 0.02 to 0.2 MPa setting G36-4-01 G46-4-01 Round type *3 (with color zone) Standard G36-10-01-L G46-10-01-L Pressure gauge 0.02
] :01 06 0050 0 A9 [CR][LF] Stop 0050 Control operation mode 1 :01 06 0050 0001 A8 [CR][LF] :01 06 0050 0001 A8 [CR][LF] Start 0051 Temperature setting 1 :01 06 0051 0BB8 E5 [CR][LF] :01 06 0051 0BB8 E5 [CR][LF] Set at 30.0 deg.C. 0052 Offset setting 1 :01 06 0052 0032 75 [CR][LF] :01 06 0052 0032 75 [CR][LF] Set at 0.50 deg.C.
VV5ZS3 02 06 51F 1 D Thread type VK Series VZS3000 Manifold Standard Nil NPT Rc N T F VZ Plug-in type Stacking type manifold base with D-sub connector NPTF G Option Port size VF Rc 1 8 02 Rc 1 4 01 U side Connector mounting direction VFR Connector mounting position Symbol Applicable stations Embedded type One-touch fitting Applicable tubing O.D.: 6 C6 VP4 U D U side D side 2 to 8 2 to 8 9
QJ61BT11N Buffer memory address Remote input (RX) RX2F RX2C RX2B RX2A RX29 RX28 RX27 RX23 RX22 RX21 RX20 E2H Reserve (H) COM D COM C COM B COM A Reserve (L) Voltage decrease Reserve (L) RX3F RX3C RX3B RX3A RX39 RX38 RX37 RX33 RX32 RX31 RX30 E3H Reserve (L) Remote READY Error state flag Reserve (L) Reserve (L): Reserved bit (0 fixing), Reserve (H): Reserved bit (1 fixing) -25No.EX-OMI0001
SJ3000-42-1A-l SJ3000-42-2A-l SJ3000-42-3A-l SJ3000-42-4A-l SJ3000-42-6A-l SJ3000-42-5A For D-sub connector For flat ribbon cable 26 pins For flat ribbon cable 20 pins m: 1 (Connector upward) For flat ribbon cable 10 pins D side m: 2 (Connector lateral) For PC wiring 20 pins For EX180 serial wiring Note) For PC wiring 20 pins with power supply terminal SJ3000-76-2A-05 Note) SI unit is not
D-A9V D-M9V D-M9WV 20 (22) 5.5 (5) ( ): Denotes the values of D-A9V.
4 6 8 10 12 3 5 10 17 25 2.8 6.5 14 24 34 9.3 11.6 15.2 18.5 21.7 33.5 37.1 53.3 63.6 70.2 2-Applicable tubing D Inch Size Weight (g) Effective area (mm2) D L M Model Applicable tubing O.D.
The proper tightening torque for screws 0.3 to 0.4 Nm Rated voltage With indicator light VZ Voltage symbol Part no. 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC 220 VAC 24V 12V 100V 200V 110V 220V AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 VS (b) VFN Valve Mounting Circuit with Indicator Light After confirming the gasket is correctly placed under the
71 30 45 2 20 175.5 n= NUMBER OF STATIONS (MIN. 2,MAX.10) LENGTH FORMULA L1= 43n + 72 L2= 43n + 84 LENGTH FORMULA L1= 56n + 90 L2= 71n + 90 L1= 71n + 66 LENGTH FORMULA L2= 56n + 106 LENGTH DIMENSIONS LENGTH DIMENSIONS LENGTH DIMENSIONS SIZE 1 SIZE 2 SIZE 3 n 3 2 n n 2 3 4 5 6 7 8 9 10 7 5 4 6 9 8 10 5 4 3 2 9 8 7 6 10 L L L L1 258 202 314 482 426 538 594 650 L1 208 279 350 421 492 563 634
SY SYJ VK Blank plug KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 VZ L Dimensions VT A One-touch fitting d Part No. A L D VT KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 3.2 4 6 8 10 16 16 18 20.5 22 31.5 32 35 39 43 3.2 6 8 10 12 D VP Color: White VG VP L DIN rail AXT100-DR-l 12.5 (Pitch) 5.25 7.5 VQ Enter suffix number into l from the table below.
Low Speed Cylinder Double Acting, Single Rod Series CQSX 12, 16, 20, 25 How to Order CQSX D B 20 30 Without auto switch 30 F9BW B 20 CDQSX D With auto switch Number of auto switches Built-in magnet 2 pcs. 1 pc. n pcs.
L) ELW53HK8DCCP (G or L) ELW53JJ8DCCP (G or L) ELW53JV8DCCP (G or L) ELW53JK8DCCP (G or L) ELW53VV8DCCP (G or L) ELW53VK8DCCP (G or L) ELW53KK8DCCP (G or L) 215 215 135 70 55 120 120 70 55 85 70 55 50 50 35 135 120 50 35 30 70 50 35 30 40 35 30 30 30 20 215 120 40 30 25 120 40 30 25 40 30 25 30 25 25 135 65 30 20 15 65 30 20 15 30 20 15 20 15 15 G 132 G 132 DE-ENERGIZED ENERGIZED G 132 H
L) ELW53HK8DCCP (G or L) ELW53JJ8DCCP (G or L) ELW53JV8DCCP (G or L) ELW53JK8DCCP (G or L) ELW53VV8DCCP (G or L) ELW53VK8DCCP (G or L) ELW53KK8DCCP (G or L) 215 215 135 70 55 120 120 70 55 85 70 55 50 50 35 135 120 50 35 30 70 50 35 30 40 35 30 30 30 20 215 120 40 30 25 120 40 30 25 40 30 25 30 25 25 135 65 30 20 15 65 30 20 15 30 20 15 20 15 15 G 132 G 132 DE-ENERGIZED ENERGIZED G 132 H
less 200 or less Calcium hardness [mg/L] 50 or less 150 or less Ionic silica [mg/L] 30 or less 50 or less Iron [mg/L] 0.3 or less 1.0 or less Copper [mg/L] 0.1 or less 0.3 or less Sulfide ion [mg/L] Should not be Should not be Referential detected any detected any item Ammonium ion [mg/L] 0.1 or less 1.0 or less Residual chlorine [mg/L] 0.3 or less 0.3 or less Free carbon dioxide [mg/L]
K1 A V ZX1 5 Z B D M L 15 C 0X B ZSP1 D L AMJ Applicable nozzle diameter Piping specifications Unit for replacement Nil L Grommet (0.6 m) Grommet (3 m) C Connector (0.6 m) CL Connector (3 m) CN Without connector For ejector system Manifold All ports are equipped with plugs.
AK AS121FG AS131FG AS221FG-01 AS231FG-01 AS221FG-02 AS231FG-02 VCHC Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa ASR ASQ 07, 08, 09, 10, 11 05, 06, 07, 08, 09, 10 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 01, 03, 04 05, 06 03, 04 Number of needle rotations Number of needle rotations Number of needle rotations AS321FG AS331FG AS421FG
(mm) 4 6 8 10 12 (1) AS221FE-01 AS231FE-01 20, 25, 32 R 1/8 AS221FE-02 AS231FE-02 20, 25, 32, 40 R 1/4 AS321FE-03 AS331FE-03 40, 50, 63 R 3/8 AS421FE-04 AS431FE-04 63, 80, 100 R 1/2 Note 1) Elbow type only Note 2) Distinction between meter-out/meter-in types by appearance Those are distinguished by the lock nut.