Current (% for chiller main breaker volume) HRS100-A/W-20 4 h 2 h 1 h 4 min 6 min 10 min 14 min 20 min 30 min 2 min 1 min Operating time 20 s 30 s 10 s Max. 5 s 2 s 1 s Min. 0.5 s 0.2 s 0.1 s 0.05 s 0.02 s 0.01 s 100 125 200 300 500 400 600 700 1000 2000 3000 4000 5000 6000 7000 10 1500 Current (% for chiller main breaker volume) 28 Series HRS100/150 Specic Product Precautions 5 Be sure to
Cylinder: MXP10-10 Mounting: Horizontal wall mounting Average speed: Va = 300 [mm/s] Load mass: W = 0.2 [kg] L2 = 20 mm L3 = 30 mm Model to be used Model to be used Mounting orientation Mounting orientation Average speed Va (mm/s) Average speed Va (mm/s) W W Load mass W (kg): Fig. (1) Load mass W (kg): Fig. (1) L3+A3 L3+A3 Overhang Ln (mm): Fig. (2) Overhang Ln (mm): Fig. (2) L2
Bore size (mm) MM W TC NA P S TA ZZ WA WH 30 30 25 20 20 20 20 20 M8 M10 X 1.25 M10 X 1.25 M14 X 1.5 M18 X 1.5 M18 X 1.5 M22 X 1.5 M26 X 1.5 24 29 35.5 44 55 69 80 100 M5 M5 Rc(PT)1/8 Rc(PT)1/8 Rc(PT)1/4 Rc(PT)1/4 Rc(PT)3/8 Rc(PT)1/2 77 77 79 87 102 102 122 122 11 11 11 12 13 13 M5 M6 X 0.75 M8 X 1.0 M10 X 1.25 M12 X 1.25 M14 X 1.5 147 157 159 187 218 218 264 264 16 16 16 16 18 18 22
3 4.5 8 9.5 4 Section AA' 6-M3 x 0.5, depth 14 15 15 Mounting reference planes D B Q QL Without magnet and rail 8 2-M2 x 0.4, depth 3 3.15 2.5 (mm) G Model Z J H K L M QL Q S V W L MXP8-10 8 52 60 40 44 10 21 20 20 32 32 14 2-M2.5 x 0.45, depth 4 MXP8-20 50 20 82 36 36 41 20 74 65 90 50 20 8-8-27
type W, only DC voltage is available.
Applied voltage 24 V 0 V Standard With power saving circuit 0.4 W 0.1 W 0 W 62 ms 1-5-76
77 Series SYJ3000/5000/7000 Specific Product Precautions 4 Be sure to read before handling. Surge Voltage Suppressor How to Use DIN Terminal
(SNJ-016B for 10, SNKJ-016B for 16) (mm) Bore NN NB NA MM KA H GB GA FZ FY FX FT FC FB F CB CA BB BA Z A S 10 9.5 12.5 M4 X 0.7 4.2 28 5 8 42 20 33 2.3 M10 X 1.0 5.5 17.5 8 14 17 12 15 74 15 46 16 9.5 12.5 M5 X 0.8 5.2 28 5 8 42 20 33 2.3 M12 X 1.0 5.5 19 8 20 20 18 18 75 15 47 Double Clevis (D) CJ2KD Bore size Stroke Material: Iron Part No.
500 600 V(mm/s) V (mm/s) V(mm/s) LEFS16 LEFS25 LEFS32 Vertical Transfer 12 50 B B B 20 A 10 A A 40 H W(kg) W(kg) H 8 W(kg) 15 30 6 10 20 4 5 2 10 0 0 0 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 0 200 400 600 800 1000 1200 V (mm/s) V (mm/s) V(mm/s) LEFS16 LEFS25 LEFS32 50 12 B B 20 B A 10 A 40 H H A W(kg) W(kg) W(kg) 15 8 30 6 10 20 4 5 10 2 0 0 0 0 100 200 300 400 500 600 0 100
to 350 Note 4) Basic Compact Basic Compact Basic Compact Basic Compact Basic Compact Horizontal Max. work load [lb] Note 2) Note 3) Vertical Actuator specifications Electric specifications 20 to 300 Note 4) Horizontal 20 to 350 Note 4) Speed [mm/s] Note 3) Note 6) 20 to 300 Note 4) 20 to 300 Note 4) Vertical 20 20 to 300 Note 4) Pushing speed [mm/s] Note 5) 20 Acceleration/Deceleration
Grease pack part number: GR-S-010 (10 g), GR-S-020 (20 g) 16 CP96N Series Dimensions (Double Rod) GD2 GB EE Rod side cylinder port EE Head side cylinder port Basic: CP96NB-W GC GA GD1 GC GD2 GB WA2 WB2 PL 2 x 4 x RT BG WB2 WA2 WA1 WB1 GA BP GF 32 80, 100 Manual lock release bolt Width across flats KC Cushion valve BP Unlocked when pressurized 4 x RT Thread depth BG L2 E1 R V Width across
PB06 GD2 4.0 PB07 PG1 100 rad/s PB08 PG2 120 rad/s PB09 VG2 3000 rad/s PB10 VIC 20 ms PB19 VRF1 50 Hz PB20 VRF2 50 Hz PB29 GD2B 10.0 PB30 PG2B 84 rad/s PB31 VG2B 4000 rad/s PB32 VICB 50 ms PB26 CDP 0001 ( ) PB28 CDT 100 ms PB33 VRF1B 60 Hz PB34 VRF2B 60 Hz (b) OFF OFF ON 63.4 CDT100ms 100 4.0 10.0 4.0 120 84 120 3000 4000 3000 20 50 20 50 60 50
40 10 95 17 56.5 20 13 15 12 11 M8 X 1.25 7 18 to 600 MGG 35 32 86 27 115 1/4 1/4 64 20 40 10 102 17 67 20 18 12 15 11 M10 X 1.25 7 18 to 600 40 37 102 32 139 1/4 1/4 78 25 52 14 123 21 83 20 23 18 17 13 M12 X 1.75 11 22 to 750 MGC 40 37 116 41 160 1/4 1/4 92 30 52 14 144 21 98 22 25 20 19 16 M12 X 1.75 11 26 to 750 (mm) MGF Bore (mm) LD LH LS LT LX LY MM N P Q H S T V W X Y Z ZZ CY1 40
25C Ambient temperature 2C 0.5 0.5 Ambient temperature 2C 0 0 15 20 25 Circulating fluid temperature [C] 15 20 25 Circulating fluid temperature [C] HRLE050-W-20 HRLE050-W-20 [50 Hz] [60 Hz] 2 2 Heating capacity [kW] Heating capacity [kW] 1.5 1.5 Facility water temperature 25C, 32C, 40C Facility water temperature 25C, 32C, 40C 1 1 0.5 0.5 0 0 15 20 25 Circulating fluid temperature [C] 15
HRS100-A/W-20/40, HRS150-A/W-40 4 h 2 h 1 h 4 min 6 min 10 min 14 min 20 min 30 min 2 min 1 min Operating time 20 s 30 s 10 s Max. 5 s 2 s 1 s Min. 0.5 s 0.2 s 0.1 s 0.05 s 0.02 s 0.01 s 100 125 200 300 500 400 600 700 1000 2000 3000 4000 5000 6000 7000 10 1500 Current (% for chiller main breaker volume) 123 HRS100/150 Series Specific Product Precautions 5 Be sure to read this before handling
Applicable Series C85 C85W C85-S/T C75-S/T C85K-S/T C75K-S/T C85K C75K C75R CP96 CP96K C96 C96K C96Y C55 C85R C75 C75W Auto Switch Description Model Action Standard type CP96S Double acting, Single rod CP96S-W Double acting, Double rod * There is a maximum stroke limit for CP96 cylinder.
JIS B2401G35 3 pcs. 56 Series AMF Dimensions AMF150C to 350C P Q T S R F E D N Bracket L U (Accessory) O K G M V W J B OUT IN C I A Maintenance space (mm) A Model Port size Bracket related dimensions B C D E F G I 98.5 N 56 J 20 K 5 U 6 V 6 L 12 M 6 W 10 O 35 P 70 Q 26 R 54 S 4.5 T 1.6 AMF150C AMF250C AMF350C 10 54 63 7.5 63 10 1/8, 1/4 83 14 73 76 5 76 10 121 66 24 8 6 6 12 6 10 40 80 28
XX W-AREA1 Stroke(-)to Stroke (+) of the basic parameter If W-AREA1 >W-AREA2, the alarm Parameter ALM will be activated.(However,no alarm is generated if W-AREA1= WAREA2= 0, the WAREA output will be turned OFF) XX W-AREA2 ORG Correct [Link Offset] Fixed value This is the fixed value for this driver.
adsorption surface How to Order 3507 W N ZP2 Pad unit Pad material Pad size Symbol Material NBR Silicone rubber Urethane rubber FKM Conductive NBR Conductive silicone rubber Symbol Size 3.5 x 7 4 x 10 5 x 10 6 x 10 4 x 20 5 x 20 Symbol Size 6 x 20 8 x 20 4 x 30 5 x 30 6 x 30 8 x 30 N S U F GN GS 3507 4010 5010 6010 4020 5020 6020 8020 4030 5030 6030 8030 Pad type Type Oval Symbol W Dimensions
Without auto switch C95KD B 32 100 W A53 S With auto switch Number of auto switches Auto switch Built-in magnet Mounting style Nil S 3 n 2 pcs. 1 pc. 3 pcs. n pcs.
(For details, refer to page 4-4-25.) 4-4-20 21 3 Port Pilot Operated Solenoid Valve Rubber Seal Series SYJ500 Construction q e r t w y q e r t w y N.C. N.O.