Material 14284 NBR Description O-ring ASP y ASN AQ ASV AK ASS ASR ASF 15-9-35
SMC has introduced an improved version of KQ2 series, and recommends that you utilize the new series for your product designs.
Speed Exhaust Controller Series ASV Size: M3, M5, 1/8, 1/4, 3/8 How to Order Integration of a quick exhaust valve and an exhaust restrictor permits high-speed cylinder operation. S K 3 1 0 F 01 06 ASV Speed exhaust controller Option Nil None The effective area is two times larger.
SMC has introduced an improved version of KQ2 series, and recommends that you utilize the new series for your product designs.
SMC has introduced an improved version of KQ2 series, and recommends that you utilize the new series for your product designs.
Retainer prevents an accidental loss of needle.
function Meter-out control ASS500 52.0 1/2, 3/4 55.0 580 ASS600 80.0 3/4, 1 90.0 950 ASS110 2.4 1/8 5.4 97 Meter-in control ASS310 16.5 1/4, 3/8 23.0 220 Specifications Air Fluid 0.7 MPa Max. operating pressure AS 5 to 60C (No freezing) Ambient and fluid temperature 0.1 to 0.5 MPa Set pressure ASP How to Order ASN 02 B ASS 00 3 AQ ASV Body size Accessory 1 8 Nil None With bracket 1 3 5 6 AK
Material 14284 NBR Description O-ring 6 AS-T ASP ASN AQ ASV AK VCHC ASR ASQ 657
The AK is a general check valve, and the AKM is a check valve that connects modularly between the AR (regulator) and the AL (lubricator) of an AC unit. It also features a branch piping port on the inlet side of the check valve to prevent lubricant from flowing into the branch piping side where lubrication is not desired.
It is an assembly of a piston and a gasket (KSYP-13).
Never use them in the presence of an explosive gas, as this may cause a serious explosion 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside cylinders will become demagnetized if used in such an environment. 3. Do not use in an environment where the auto switch will be continually exposed to water. 1.
Use caution, because an external action such as an impacting load, strong vibration or turning force, may damage the locking mechanism or reduce its life. 20Data Stop signal Amount of overrun 6-12-29 Series C95N Specific Product Precautions 2 Be sure to read before handing. Adjustment Pneumatic Circuit Mounting Warning Warning Warning 2. Do not apply an offset load to the piston rod.
Take appropriate measures to avoid freezing of drain, moisture etc. by use of an air dryer. Not suitable for use as an emergency shutoff valve The valve represented in this catalog is not intended for use as an emergency shutoff valve.
ZS-46-B Panel mount adapter ZS-46-D Panel mount adapter + Front protection cover ZS-46-5L Power supply/output connection lead wire 5-core, 2 m ZS-27-01 Front protection cover B Panel mount adapter Connection Example ZS-46-B PFG300 Sensor connector D Panel mount adapter + Front protection cover PF3A7 H Power supply/output connection lead wire ZS-46-D Lead wire and M12 connector (Option for
Note) The high pressure switch can also be in operation for IDFB55E-46 and IDFB75E-46.
Note 4) F, P, T and S kits are provided with an exhaust on one side, while C kits are with an exhaust on both sides. The number of max. stations differs from kit to kit. (Refer to the table below.)
When the conduit type is used as equivalent to an IP65 enclosure, install a wiring conduit, etc. 9. When an impact, such as water hammer, etc., caused by the rapid pressure fluctuation is applied, the solenoid valve may be damaged. Give an attention to it. 3. Corrosive gas Cannot be used since it will lead to cracks by stress corrosion or result in other incidents. 4.
Power supply cable (LEC-CK1-1) is an accessory.
The rotation range under the adjustment of an angle at 60 is indicated below.
There is no mounting interchangeability with serise CA2. 6-6-46