Air Piping Compressor Air Delivery Caution Caution HAA HAW IDFA55E, 75E Compressed air inlet Compressed air outlet Use an air compressor with an air delivery of 100 L/min or larger with the IDFA3E to 75E series.
With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) Max. 16 stations Kit P Kit P Kit J Kit J Kit F Kit F L S The valve is equipped with an indicator light/surge voltage suppressor, and the voltage is 24 VDC. kit (Serial transmission unit) kit (Lead wire cable) The dust-protected type SI unit is applicable
Mounting orientation and static moment Mounting orientation Static load Horizontal mounting Ceiling mounting Wall mounting Vertical mounting Bore size (mm) A [mm] 6 10 15 20 25 32 40 m m x g x x m x g x y 19 21 25 27 33 40 49 m x g x x m x g x y m x g x (z + A) m x g x x m x g x (z + A) m x g x y M1 M2 M3 Static moment A: Distance between the center of the guide shaft and the upper surface
L dimension 1.5 m 3 m 5 m Part no. L dimension 1.5 m 3 m 5 m AXT100-MC26-015 AXT100-DS25-015 AXT100-MC26-030 AXT100-DS25-030 AXT100-MC26-050 AXT100-DS25-050 When a commercially available connector is required, use a 25 pin female connector conforming to MIL-C-24308. L L (60) 44 Approx. 10 8 16 14 25 1 13 47.04 55 Multi-core vinyl cable 0.3 mm 2 x 25C 2 x M2.6 x 0.45 Terminal no.
M: Contents revised in several places.[March 2017] N: Contents revised in several places.
Consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Solid state auto switches marked "" are produced upon receipt of order.
+ 128.2 W = 13n + m + 36 W = 41.2n + m + 77.6 (n: Number of SUP/EXH blocks, m: DIN rail weight) Note 1) In cases such as when many valves are operated simultaneously, supply pressure to port P on both sides and exhaust from port R on both sides, using "stations B (SUP/EXH block both sides)".
M5 x 0.8 Width across flats 8 Effective area: 4.0 mm2 Weight: 3.7 g Gasket: M-5G1, M-5GH Weight: 0.01 g Weight: 0.04 g 15-3-28
Out put type Current consumption Flow switch SMC PF2W7--27(-M) NPN open collector output 70mA or less PF2W7--67(-M) PNP open collector output 70mA or less 1. Prepare the external switch 2. Depending on the external switch output type, wire the switch to the communication connector for contact input / output (which is included as an accessory) as shown below.
Use an air filter with 5 m or less filtration rating on the inlet side of the valve to avoid any damage to the seat caused by dust when mounting a 3-port valve for residual pressure release on the inlet side. Mounting and Adjustment Caution 1.
Add M to the end of the part number for 1 m, L for 3 m, and Z for 5 m. Example) -2M9NL !
41.5 48 56 80 83 86.5 D-F7lWV 5 14 18 40 45 42.5 39.5 46 54 78 81 40.5 D-A9ll 3 12 16 38 43 81.5 46 52.5 60.5 84.5 87.5 91 D-F7NT 9.5 18.5 22.5 44.5 49.5 47 43.5 50 58 82 85 88.5 D-F9ll 7 16 20 42 47 44.5 42.5 49 57 81 84 87.5 D-F9lWl 6 15 19 41 46 43.5 4.4-16
How to Order Type 46 (5 Port/Base mounted) Applicable solenoid valve SYJ340SYJ343SS5YJ3 46 05 M5 Type 46 Type S46 ( ) Single solenoid coil is on same side as the A, B port. M5 x 0.8 R1 R2 port Applicable blanking plate assembly SYJ3000-21-2A Stations Valve mounting direction 02 2 stations Single solenoid coil is on opposite side as the A, B port.
The kinetic energy of a load can be found using the following formula. 20 10 5 M 100 300 1000 2000 500 M 2 2 Ek = Maximum drive speed (mm/s) Ek: Kinetic energy (J) M: Weight of load (kg) : Piston speed (m/s) Example) Find the rod end load limit when a 63 air cylinder is operated at a maximum drive speed of 500mm/s.
terminal B2 B1 J K J K J K M J K M N Q R S T N.C., N.O., COM.
MK40-M MK50-M MK63-M MVGQ M8 x 1.25 25 9 35.5 18 45 36 20 53.5 67 14 18 6 6.2 M8 x 1.25 25 9 43 18 45 36 20 61 67 14 18 6 6.2 CC M10 x 1.5 40 11.5 53 23 65 46 22 77 88 18 22 8 8.2 M10 x 1.5 40 11.5 52.5 23 65 46 22 76.5 88 18 22 8 8.2 RB J Mounting arms for width across flats D-X 20Data When installing the arm for the parllel section at the rod end, the strength of the piston rod might be
Compressed air can be dangerous if an operator is unfamiliar with it.
Model Model ZPR20B-0-A10 ZPR40B-0-A14 23.5 38.5 49.3 67.1 12.4 47.5 58.3 76.1 24.4 20 40 25 48 16 22 43 34 10.5 25 ZPR25B-0-A10 19 ZPR50B-0-A14 50 24 39 49.8 67.6 15.6 51.5 62.3 80.1 32.4 28 57 27 53 38 14 ZPR32B-0-A10 32 29 44 54.8 72.6 18.9 37 34 Dimensions by Stroke Dimensions by Stroke 40 50 J K: 6 K: 8 Model 20 25 32 J K: 4 K: 6 K: 8 G H G H L M L M Model G H G H G H L M L M L M ZPRB10
Coil with a full-wave rectifier (electrical option R) (mm) Grommet Conduit DIN terminal Conduit terminal Electrical entry (DC, AC) Applicable flange Model M A B C D E F H J K L N 22.5 25.5 25.5 M N 43 46 46 M 89 N 61.5 64 64 Q 49.5 52 52 M N 95 98 98 Q 64 66.5 66.5 Normally closed VXD2272 VXD2382 VXD2392 Normally open VXD2270 VXD2380 VXD2390 32A 40A 50A 12 14 14 35 40 40 22.5 25 25 67.5 70
Please contact SMC regarding water-resistant types with the above model numbers. * Solid state auto switches marked with v are produced upon receipt of order. * Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ * Since there are other applicable auto switches than listed above, refer to page 185 for details. * The D-A9l