SMC Corporation of America
Elite Part Number Search
Search Results "CXS2L10-110"

Note 3) For wear ring A of 10, please consult with SMC. 110 Magnetically Coupled Rodless Cylinder/Direct Mount Type: Both Sides Piping Type Series CY3R 6, 10, 15, 20 25, 32, 40, 50 63 Replacement Procedure is P.316 Construction Both sides piping type Actuators Modular F.R.L.

1.0 S 63 63 83 W 25 30 35 X 10 16 19 Model CY1B6 CY1B10 CY1B15 ZZ 81 81 103 Port size M5 x 0.8 M5 x 0.8 M5 x 0.8 CY1B20 to 40 CY1B50, 63 (mm) B 36 46 60 70 86 100 MM x J M4 x 0.7 x 6 M5 x 0.8 x 8 M6 x 1.0 x 8 M6 x 1.0 x 10 M8 x 1.25 x 12 M8 x 1.25 x 12 C 32 38 D 22.8 27.8 35 43 53 66 E 30 32 G 8 8 9 11 14 14 H 20 20.5 22 29 33 33 I 28 34 40 50 58.2 72.2 K 8 10 15 16 25 26 L 66 70 80 92 110

0.39 2.2 0.97 [0.61] 0.23 [0.32] 4.3 [2.4] SZ 1(P) port Rc 114 116 122 124 0.82 0.37 3.2 0.77 0.26 3.2 2 position 1 4 C8 SY 0.62 0.31 2.4 0.63 0.24 2.6 SX720--C8 5, 3 (EA, EB) Port One-touch fitting for 8 Exhaust center Pressure center Single Double Closed center 0.70 [0.56] 0.42 [0.46] 2.6 [1.9] 0.57 0.25 2.4 131 132 3 position SYJ 0.60 0.34 2.2 0.78 [0.57] 0.28 [0.22] 3.3 [2.4] Rc 1 8 110

(mm) Weight (g) L1 L2 L3 D1 D2 Model L1 Nylon Urethane KQ2V04-M5 KQ2V04-01S KQ2V06-M5 KQ2V06-01S KQ2V06-02S KQ2V08-01S KQ2V08-02S KQ2V08-03S KQ2V10-02S KQ2V10-03S KQ2V12-03S KQ2V12-04S KQ2V16-03S KQ2V16-04S 6 14 7 15 26 24 30 47 40 49 63 80 103 110 Reference dimensions after R thread installation. Note 1) D: Max. diameter Note 2) ( ): Values for soft nylon.

MGG MGC (mm) MGF Stroke range Bore size (mm) D1 J K M B D C E KA GA GB H MGZ 11 12 22 25 25 25 25 51 57 66 78 92 110 144 M5 x 0.8 M5 x 0.8 M6 x 1 M6 x 1 M8 x 1.25 M8 x 1.25 M12 x 1.75 8 8 10 10 14 14 20 39 43 49 59 71 82 106 29 33 38 46 55 66 86 25 30 36 45 55 68 87 11 12 16 21 26 32 36 21 24 30 36 46 53 65 16 26 28.5 34.5 40 46.5 54 20 21 35 40 45 50 50 20 25 32 40 50 63 80 12.5 18 19.5

0.8 0.7 100 2.6 2 1.6 1.4 1.2 1 0.9 110 3.5 2.6 2 1.7 1.4 1.2 1.1 www.poweraire.com 1-800-526-7661 27 Section IV: Charts Vacuum Flow Trough Orifices The chart below approximates flow that would be expected thorugh a practical orifice.

LD 3.6 LH 38 LL 35 LW 84 M 6.0 MM N 20 NC 14 NE 49.5 NH 16.5 Bore size (mm) 16 20 090 M5 x 0.8 M4 x 0.7 110 7.5 4.5 26 12.5 12.5 20.0 58 33.7 M6 x 1 12 130 4.8 39 45 88 7.5 M5 x 0.8 25 17 55.5 21.7 NW PA PB PG PP Q QQ QW RR SS TT UU VV W WW YW Z XX Bore size (mm) 16 20 07.5 11.5 56 60 40 50 94 100 3.5 4.5 153 191 9 10 48 45 11.0 14.5 2.5 5.5 15 18 14 12 10.0 12.5 102 110 13 14 54 58 180

0.8 0.7 100 2.6 2 1.6 1.4 1.2 1 0.9 110 3.5 2.6 2 1.7 1.4 1.2 1.1 www.poweraire.com 1-800-526-7661 27 Section IV: Charts Vacuum Flow Trough Orifices The chart below approximates flow that would be expected thorugh a practical orifice.

Internal wiring 1 3 5 6 M5 C4 C6 VZ323MOZApplicable valve model Rated voltage 100 VAC 50/60 Hz, 110 VAC 50/60 Hz, 24 VDC, 12 VDC Note ) Withstand voltage specifications of wiring unit part is equivalent to JIS C 0704 class 1.

VXA 2 1 VCHm Thread type 1 Rc NPT G Nil N F VDW Voltage VQ 1 2 3 4 7 8 J 100 VAC 200 VAC 110 VAC 220 VAC 240 VAC 48 VAC 230 VAC Port size LVM Class 3 v v v Class 2 v v Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 v v v v Symbol 01 02 03 04 06 VCA VCB Please consult with SMC regarding other voltages.

RSG-L Bore size: 40, 50 Workpiece transfer direction 36 98 + Stroke (12) 31 M45 x 1.5 (Rc 1/8, NPT 1/8, G 1/8) 16 16 13.5 14 7.5 2 10 9 (Rc 1/8, NPT 1/8, G 1/8) 60 0 0.05 20 R38 24 25 14 80 60 0.15 A 8 38 18 80 60 0.15 67 + Stroke 110 + Stroke 4 x 9 through 177 + 2 stroke Built-in One-touch fittings Tubing O.D.

DXT170-176-2-01 DXT170-176-2-02 100 V 200 V 100 VAC 200 VAC Lead wire length Symbol Lead wire length (L mm) DXT170-176-2-03 110 V 110 VAC DXT170-176-2-04 220 V 220 VAC Nil 300 240 V 6 VD 12 VD 24 VD 48 VD DXT170-176-2-07 DXT170-176-3-51 DXT170-176-3-06 DXT170-176-3-05 DXT170-176-3-53 240 VAC 6 10 15 20 25 30 600 6 VDC 12 VDC 24 VDC 48 VDC 1000 1500 2000 2500 3000 Connector with light circuit

Indicator light LED Can be used for 110 VAC and 115 VAC, 220 VAC and 230 VAC in common.

.: Black B 1/8 1/4 10 One-touch fitting Barb fitting Applicable tubing: T0604 M5 x 0.8 Width across flats 17 Width across flats 17 Standard specifications Bracket mount Model Port size A B C D P E F G H1 H2 J K L L M (1) (1) (1) (1) ACG20 ACG30 ACG40 1/8, 1/4 126 87 36 60 28.5 41.5 43 30 24 5.5 3.2 1/4, 3/8 167 115 41 80 30 55 57 41 35 35 14 7 7 4 1/4, 3/8, 1/2 220 147 48 110 38 72.5 75

(different sides/same side) 10 100 100 110 120 D-A5, D-A6 D-F5, D-J5 (n 4) 2 (n 4) 2 (n 4) 2 (n 4) 2 (n 2) 2 "n" pcs. (same side) 10 + 55 110 + 55 120 + 55 100 + 55 100 + 55 n = 2, 4, 6, 8 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 2 pcs. (different sides/same side) 20 100 100 110 120 D-A59W (n 4) 2 (n 4) 2 (n 4) 2 (n 4) 2 (n 2) 2 "n" pcs.

Panel adapter B ZS-22-02 Specifications PF2W300/301 PF2W330/331 Model Flow rate measurement range Note 1) 0.35 to 4.5 l/min 1.7 to 17.0 l/min 3.5 to 45 l/min 7 to 110 l/min Set flow rate range Note 1) 0.35 to 4.5 l/min 1.7 to 17.0 l/min 3.5 to 45 l/min 7 to 110 l/min Minimum set unit Note 1) 0.05 l/min 0.1 l/min 0.5 l/min 1 l/min Accumulated pulse flow rate exchange 0.05 l/pulse 0.1 l/pulse

For sub-plate style, mainfold type 40, 41, 41R, 42, 42R Port size E: Push-turn locking lever type 02: 1/4 port With sub-plate 01: 1/8 port With sub-plate Nil: Without sub-plate Body option Nil: Individual pilot exhaust style (With gasket and screws) Electrical entry Grommet L plug connector 24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 24, 12 VDC/ 100, 110, 200, 220 VAC M plug connector DIN

JIS Symbol Solenoid Valve Specifications Applicable solenoid valve model Series VZ390 Standard: 100/200 VAC (50/60 Hz), 24 VDC Option: 110/220 VAC, 12 VDC Coil rated voltage 4.5mm2 (0.25) Effestive area of valve (Cv factor) Allowable voltage 15 to 10% Coil insulation Class B or equivalent (130C) Electrical entry Grommet, L plug connector, M plug connector, DIN terminal Power consumption (

servo motor (200 VAC) Encoder Absolute 20-bit encoder (Resolution: 1048576 p/rev) LEY -X5 Power consumption [W] Note 6) Horizontal 29 41 72 Vertical 11LEFS Standby power consumption when operating [W] Note 7) Horizontal 2 2 2 Vertical 11LEJS Max. instantaneous power consumption [W] Note 8) 445 725 1275 Type Note 9) Non-magnetizing lock Lock unit specifications 25AHolding force [N] 27 54 110