When a load, such as a relay or solenoid valve, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 2) Although wire length does not affect switch function, use wiring 100m or shorter. 5. Take precautions for the internal voltage drop of the switch.
When a load, such as a relay or solenoid valve, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 2) Although wire length should not affect switch function, use wiring 100m or shorter. 5. Take precautions for the internal voltage drop of the switch.
Although wire length should not affect switch function, use a wire 100m or shorter. 3. Do not use a load that generates surge voltage. Although a zener diode for surge protection is connected at the output side of a solid state auto switch, damage may still occur if the surge is applied repeatedly.
How to Order T 0604 B 20 Length per roll Color Symbol Color Nylon tubing 20 100 Max. operating pressure is 1.3 max of burst pressure at 60C, considering the safety ratio. 20m 100m roll B W R BU Y G Black White Tubing size Red Blue O.D. 6, I.D. 4 Yellow Green 1.17-15 D.P. Lube Series ALD600/900 Standard Specifications AC Centralized control of multi-point lubrication (1) Model name D.P.
(mm) +0.2 0.1 +0.2 0.1 0.1 0.1 Tolerance Basic diameter 1.0 1.6 0.5 1.5 0.5 0.8 1.2 Thickness (mm) 0.1 0.15 0.05 0.15 0.05 0.08 0.12 Tolerance 10m 20m Bundle 50m 100m Straight pipe 2m Translucent (color of material) Color Please refer to the applicable fluid in Feature 6.
The unit conversion between SI and conventional units are as follows: Oscillation acceleration 100m/s2 = 10.1972G Pressure 1MPa = 10.1972kgf/cm2 Cylinder thrust/load 100N = 10.1972kgf Standard air: Symbol (ANR) Torque 1Nm = 10.1972kgfcm Temperature 20C {293K}, Air with Moment of inertia 1kgm2 = 10.1972kgcm/s2 an absolute pressure of 760 mmHg Kinetic energy 1J = 10.1972kgcm {101.3kPa}, and