High speed or high load cylinder applications frequently require additional speed and flow control devices to control the stopping of the load. SMC's RHC series features a longer cushion design which is capable of stopping heavy or high speed loads while maintaining the simplicity of a standard air cushion cylinder. This enhanced cushion allows the kinetic distance, which results in the
The RSQ series is a fixed-height stopper cylinder with proven endurance and low breakaway characteristics. The RSG series is an adjustable mounting height stopper cylinder. It can be raised or lowered according to the distance required to stop the work piece. The RSH heavy-duty stopper cylinder is specially designed for use on conveyor lines or other applications requiring an external stopping
The KQ series has been discontinued, please see the New KQ2 series , One-touch fittings, metric size , Connection thread: M, R(PT), Rc(PT) , Body color: black , Release button: blue , Tube material: nylon, soft nylon, polyurethane, FITTING *LQA, CONNECTORS, KQ ONE TOUCH FITTING, CQ, KQ 4MM, 0.02504 lb
The KQ series has been discontinued, please see the New KQ2 series , One-touch fittings, metric size , Connection thread: M, R(PT), Rc(PT) , Body color: black , Release button: blue , Tube material: nylon, soft nylon, polyurethane, FITTING *LQA, CONNECTORS, KQ ONE TOUCH FITTING, CQ, KQ 4MM, 0.06935 lb
Part Number Description: FOOT BRACKET (2 REQUIRED) Product Line: A Product Line Description: ACTUATOR Family Code: 420 Family Description: CG ROUND BODY CYLINDER Class Code: N2 Part Code: 2 Reference Code: E This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number
CQ-LZ12 CQ-L016 CQ-LZ16 CQ-L020 CQ-LZ20 CQ-L025 CQ-LZ25 CQ-L032 CQ-L040 CQ-L050 CQ-L063 CQ-L080 CQ-L100 Without switch 12 CQ-F012 CQ-D012 Special port location, with auto switch 12 to 25 only With switch Full length dimension is the same as Series CQ1, Except 16, 25.
Same sectional area as that of Series CQ2. 12,16 3.00 5 10 100 300 Stroke + Eccentric distance (mm) Lateral load resistance: 3 to 4 times that of standard Series CQ Non-rotating accuracy: 0.2 o or less + 0.1 + Series MGP Series MG 0.2 CQM Non-rotating accuracy + 0.5 + 1 Non-rotating Series CQ2K Non-rotating Series CQ2K Lateral load resistant Series CQ2 Lateral load resistant Series CQ2 2
phase difference output Output signal CQ-L050 CQ-F050 CQ-D050 500V DC, 50M or more (between bowl and 12E) Insulation resistance CQ-L063 CQ-F063 CQ-D063 33.3Hz, 6.8G 2hrs. each in X, Y directions 4hrs. in Z direction based upon JIS D1601 Note 1) When ordering foot brackets, 2pcs. should be arranged for each cylinder.
Intermediate strokes are available by using spacers with standard stroke cylinders. 32 40 50 63 CVQ-L032 CVQ-L040 CQ-L050 CVQ-L063 CVQ-F032 CVQ-F040 CQ-F050 CVQ-F063 CVQ-D032 CVQ-D040 CVQ-D050 CVQ-D063 Bore size 32 40, 50, 63 Description Description Compatible with strokes of 1 mm increments. Compatible with strokes of 5 mm increments.
90-CQ-F020 90-CQ-F025 90-CQ-F032 90-CQ-F040 90-CQ-F050 90-CQ-F063 90-CQ-F080 90-CQ-F100 91-CQ-F012 91-CQ-F016 91-CQ-F020 91-CQ-F025 90-CQ-F032 90-CQ-F040 90-CQ-F050 90-CQ-F063 90-CQ-F080 90-CQ-F100 90-CQ-L012 90-CQ-L016 90-CQ-L020 90-CQ-L025 90-CQ-L032 90-CQ-L040 90-CQ-L050 90-CQ-L063 90-CQ-L080 90-CQ-L100 91-CQ-L012 91-CQ-L016 91-CQ-L020 91-CQ-L025 90-CQ-L032 90-CQ-L040 90-CQ-L050 90-CQ-L063
Yes. Order with the part number “CDQ2B50-30DCZ-BQ,” which includes the current cylinder as well as 2 D-A73 auto switch mounting brackets. If you have already purchased a CDQ2B50-30DCZ, please order the 2 D-A73 mounting brackets using the part number “BQ5-032.”
IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT 20 Double clevis Note 1) Note 3) Bore size (mm) Foot Flange 20 25 32 40 50 63 80 100 CQS-D020 CQS-D025 CQ-D032 CQ-D040 CQ-D050 CQ-D060 CQ-D080 CQ-D100 CQS-F020 CQS-F025 CQ-F032 CQ-F040 CQ-F050 CQ-F060 CQ-F080 CQ-F100 CQS-L020 CQS-L025 CQ-L032 CQ-L040 CQ-L050 CQ-L060 CQ-L080 CQ-L100 25 32 40 50 Note 1) When ordering foot brackets, order
IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT 20 Double clevis Note 1) Note 3) Bore size (mm) Foot Flange 20 25 32 40 50 63 80 100 CQS-D020 CQS-D025 CQ-D032 CQ-D040 CQ-D050 CQ-D063 CQ-D080 CQ-D100 CQS-F020 CQS-F025 CQ-F032 CQ-F040 CQ-F050 CQ-F063 CQ-F080 CQ-F100 CQS-L020 CQS-L025 CQ-L032 CQ-L040 CQ-L050 CQ-L063 CQ-L080 CQ-L100 25 32 40 50 Note 1) When ordering foot brackets, order
Bore size (mm) Foot (1) Flange (3) 50 CQ2X50-PS Double clevis 63 DCQ2X63-PS Gasket: 1 pc. 32 40 50 63 80 100 CQ-D032 CQ-D040 CQ-D050 CQ-D063 CQ-D080 CQ-D100 CQ-F032 CQ-F040 CQ-F050 CQ-F063 CQ-F080 CQ-F100 CQ-L032 CQ-L040 CQ-L050 CQ-L063 CQ-L080 CQ-L100 80 CQ2X80-PS Grease pack (10 g): 1 pc. -X 100 CQ2X100-PS Pneumatic Circuit 2.
Bore size (mm) Foot (1) Flange (3) 50 CQ2X50-PS Double clevis 63 DCQ2X63-PS Gasket: 1 pc. 32 40 50 63 80 100 CQ-D032 CQ-D040 CQ-D050 CQ-D063 CQ-D080 CQ-D100 CQ-F032 CQ-F040 CQ-F050 CQ-F063 CQ-F080 CQ-F100 CQ-L032 CQ-L040 CQ-L050 CQ-L063 CQ-L080 CQ-L100 80 CQ2X80-PS Grease pack (10 g): 1 pc. -X 100 CQ2X100-PS Pneumatic Circuit 2.
CQ-F020 CQ-F025 CQ-F032 CQ-F040 CQ-F050 CQ-F063 CQ-F080 CQ-F100 CQ-L012 CQ-L016 CQ-L020 CQ-L025 CQ-L032 CQ-L040 CQ-L050 CQ-L063 CQ-L080 CQ-L100 12 16 20 25 32 40 50 63 80 100 F7BV J79 12V F9BV F9B 2 wire Solid state switch J79C Connector 5V, 12V IC F7NWV F79W 3 wire (NPN) Relay PLC 24V 12V F9NWV F9NW Diagnostic (2 color) 5V, 12V IC F7PW 3 wire (PNP) F9PWV F9PW 12V F7BWV J79W F9BWV F9BW Grommet
size (mm) Foot Note 1) e g n a l F Model Double clevis CQ2 D CQ2 DZ CQ2 D CQ2 DZ CQ2 D CQ2 DZ CQ2 D CQ2 DZ CQ2 DZ CQ2 DZ CQ2 DZ CQ2 DZ CQ2 DZ CQ2 DZ CQ-L012 CQ-LZ12 CQ-L016 CQ-LZ16 CQ-L020 CQ-LZ20 CQ-L025 CQ-LZ25 CQ-L032 CQ-L040 CQ-L050 CQ-L063 CQ-L080 CQ-L100 Without switch 12 CQ-F012 CQ-D012 With switch Without switch 16 CQ-F016 CQ-D016 With switch Without switch 20 CQ-F020 CQ-D020 With
CQ-F016 CQ-F020 CQ-F025 CQ-F032 CQ-F040 CQ-F050 CQ-F063 CQ-F080 CQ-F100 CQ-L012 CQ-L016 CQ-L020 CQ-L025 CQ-L032 CQ-L040 CQ-L050 CQ-L063 CQ-L080 CQ-L100 5.0 4.0 3.0 Data 16 12 2.0 1.0 0 50 100 Cylinder stroke (mm) Note 4) Order two foot brackets per cylinder.
Example) CQ-M5x55L 4 pcs. Mounting bolt CHQ CHQ C D CHK Model C D Mounting bolt part no. Model C D Mounting bolt part no.
CQ-L040 CQ-L050 CQS-F020 F9B F9BV J79 F7BV 12V CQS-D025 CQS-F025 2 wire Solid state switch Connector J79C CQ-D032 CQ-F032 CQ-D040 CQ-F040 3 wire (NPN) Relay, PLC F7NWV F9NW F9NWV F79W Yes 24V Diagnostic indication (2 color indicator) CQ-D050 CQ-F050 5V, 12V IC circuit 3 wire (PNP) Note 3) When ordering foot brackets, order 2 pieces per cylinder.