Analog Voltage Output (1 to 5 V) Analog Current Output (4 to 20 mA) 5 20 Analog output [mA] Analog output [V] Model Max. rated flow value [l/min] Model Max. rated flow value [l/min] PFM710--C/E PFM725--C/E PFM750--C/E PFM711--C/E PFM710--D/F PFM725--D/F PFM750--D/F PFM711--D/F 10 10 (5) 1 4 25 25 (12.5) 50 50 (25) 00 0 0 100 100 (50) Max. rated flow value Max. rated flow value ( ): Fluid
D SVON input Caution Please refer to the manual or the catalogue of the electric actuator for the method of operation of the electric actuator.
170 28.3 33.3 LVH Port size 32A, 40A, 50A LVD LVQ Applicable cable O.D. 6 to 8 (D, DL) LQ LVN K (Terminal with indicator light: DL) TI/ TIL Manual override (Non-locking) Pilot port L (Conduit terminal: T) PA J (DIN terminal: D) I (Conduit: C) H (Grommet: G) PAX G (Air operated) PB Main port Main port Rc Pilot port Rc A B C D E F G H I J K L M Model VNA5-32A VNA6-40A VNA7-50A 1 8 1 4 1 4 1
Nil U 6 (Light gray) 1/4" (Orange) D side 1 2 3 Note) A DIN rail with the length specified by the number of stations is attached to the manifold.
Ventilation direction Compressed air outlet Rc 3/8 Compressed air inlet Inspection grill Rc 3/8 G Ventilation air inlet C Ventilation direction F [100VAC specification] Power cord (900) [200 to 240VAC specification] Terminal block J 63 L 20 Drain tube K H 4-13 [200 to 240VAC specification] Power cord outlet Model Port size A J B C D E F G H K L IDU3D IDU4D 246 496 509 87 125 344 23 175 151
YX Edition B Edition D The HRR010 (air-cooled type, water-cooled type) has been added. Number of pages has been increased from 36 to 44. YV Edition C Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.
JOG operation positioning operation programmed operation DO forced (Note 4) 0 0. b output single-step feed (Note 4) Test operation mode # #. d (Note 1) Motor-less operation # #.
JOG operation positioning operation programmed operation DO forced (Note 4) 0 0. b output single-step feed (Note 4) Test operation mode # #. d (Note 1) Motor-less operation # #.
(3 positions) Controller detail General 3 positions 5 positions General A 1 2 5 7 State of indicator light D B C E 8 3 4 6 Switch No.
D-R Note 3) Options for 2, 6, and 8 can not be specified at the same time. (Ex.) 68 Note 4) Symbols 9, D, J can not be specified at the same time. (Ex.) 9-D-J Note 5) For products with auto drain, either symbol D or J cannot be specified at the same time. 1 Indicate the required filtration rate after the symbol 1. Ex.)
(N.O. type/N.C. type can be changed.) 3 Do not connect wiring. 1 14 25 13 D-sub 25-pin female (socket) type 8 HRL Series Dual Channel Refrigerated Thermo-chiller for Lasers Communication Functions Serial Communication The following operations can be performed by the serial communication RS-232C/RS-485.
30 37 47.3 d M6 x 1.0 M10 x 1.0 M20 x 1.5 M26 x 1.5 M32 x 2.0 Part no.
bottom, (right) Note) Refer to the catalog for Stroke, Auto switch and Number of auto switches. 3 positions Names and Functions of Controller 11 Example of Internal Circuit and Wiring 12 Setting 15 Operation Characteristics 20 Specifications 21 10 Names and Functions of Controller (3 positions) Controller detail General 3 positions 5 positions General A 1 2 5 7 State of indicator light D
equipped as standard.) sPage 177 sPage 180 With fluid fill port 156 A Thermo-chiller Inverter Type HRSH Series Circulating Fluid Temperature Controller Circuit diagram HRSHl-W-l (Water-cooled refrigeration) HRSHl-A-l (Air-cooled refrigeration) HRS Ventilation DC inverter fan HRS 090 Water regulating valve Air release valve for facility water discharge HRS 100/150 WPR Facility water outlet D
Grounding should be to a D-class ground. (Ground resistance of 100 or less.) -13- 3. Grounding should be performed near the actuator to shorten the grounding distance. 4. The cross-sectional area of this wire shall be a minimum of 2 mm2. 5. Avoid common grounding with other devices.
Series HRS100/150 CAT.NAS40-62B R410A as refrigerant Thermo-chiller Standard Type Series HRS100/150 Circulating Fluid Temperature Controller Triple controller Fan Air-cooled condenser fan control Cooling valve Heating valve Circuit diagram Ventilation Cooling valve control Fan Facility water outlet Temperature sensor (Heat exchanger inlet) Water-cooled condenser Dryer Air-cooled condenser D
See specification table for refrigerant used in the product. 6-3 Dimensions IDFB22E / 37E UNIT : inch [mm] AIR OUTLET AIR INLET A PORT SIZE PORT SIZE B E D G AUTO DRAIN WITH LAMP SWITCH THERMOMETER EVAPORATION BALL VALVE VENTILATION VENTILATION F C BLOCK TERMINAL DRAIN TUBE LENGTH35.4[900]) (O.D.3/8 J N M H K L P 911])OPPOSITION 0.4[ WIRE ELECTRICAL ENTRY [4xDIA.13] 4xDIA.0.5 Model Port
E F C (35.4[900]) J M N P L K H 4x0..5 (0.4[9~11mm] [4x13] [IDFB22E-11*(L=2800)] Unitinch [mm] A B C D E F G H J K L M N P 30.5 23.6 IDFB22E 1 [775] [600] 3.3 11.4 24.5 5.3 15.9 27.5 3.7 1.8 1 0.5 12.4 13.4 [290] [623] [134] [405] [698] [93] [46] [25] [13] [314] [85] [340] 26.8 33.7 IDFB37E 1/2 [855] [680] R IDFB55E/75E Q A B H G E D F C (0.4 (39.4[1000]) J L K M N P 4x0..5 [4x13]
Two mounting styles Table traveling accuracy C D Bottom mount Top mount Model Traveling accuracy C side against A side D side against B side LG1H 0.1 or less 0.1 or less A B Variations Mounting orientation Lead screw type Motor type Guide type Motor/Screw connection Series Standard motor [Tamagawa Seiki Co., Ltd.]
-phase 200 VAC 3-phase 400 VAC [mm] [mm]