, 300, 400 Panel mount All models applicable Different P port location (On handle side) Note that 1(P) port of VH600 is located on handle side as standard.
L3 [mm] L3 [mm] L3 [mm] m 600 600 600 L3 Z 400 400 400 200 200 200 0 0 0 0 10 20 30 40 50 60 70 0 10 20 30 40 50 0 5 10 15 20 25 30 35 Work load [kg] Work load [kg] Work load [kg] 1000 1000 1000 800 800 800 L4 [mm] L4 [mm] L4 [mm] 600 600 600 L4 X 400 400 400 200 200 200 0 0 0 0 10 20 30 40 50 0 10 20 30 40 50 60 70 0 5 10 15 20 25 30 35 Work load [kg] Work load [kg] Work load [kg] 1000
4 x J 2 x P Width across flats KA ~ = ~ = d S + Stroke ZZ + Stroke ZZ1 + l + Stroke (mm) Stroke range Type Bore size (mm) A AL B C D E EA F FA G J K KA M MM N P S (mm) 125 140 160 180 200 250 300 1 2 1 2 3 4 3 4 3 4 to 1000 50 47 145 115 36 90 59 43 14 16 15 31 27 35 98 M14 x 1.5 M30 x 1.5 Lube Non-lube Air-hydro to 1000 50 47 161 128 36 90 59 43 14 16 15 31 27 35 98 M14 x 1.5 M30 x 1.5
C 1 LE N 1 P Controller Actuator part number Option (Except cable specifications and actuator options) Example: Enter LEFS16A-400 for the LEFS16A-400B-R11N1.
Parameter Functioning in Manual Mode For the position indication (P value), zero / span setting (parameter code: 400) functions as it is. Reflection of Changed Content in Parameter Mode The changed content is reflected at the time when the mode moves from parameter to manual, and then moves to auto mode*1.
Air flow SW:1 10 10 Air flow SW:10 5 5 Air flow SW:10 0 0 0 200 400 600 800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 Installation distance mm Installation distance mm 28 Doc.
500 280 560 10 4 8 7 6 5 MXY12 3 2.0 Shock absorber Rubber stopper screw 2 4 Load mass W kg 1.5 Metal stopper screw 3 1.0 1 100 50 200 300 400 560 2 100 50 200 300 400 500 Average speed Va mm/s Collision speed V mm/s 0.5 Average speed Va mm/s 0.0 Collision speed V mm/s 0 100 200 300 400 500 280 560 Note) Use the average speed when calculating static moment.
Driver for Non-standard Motor Regenerative Absorption Unit Series LC7R Teaching Box Dedicated AC Servomotor Controller Series LC1 P. 205 P. 200 P. 185 P. 196 Features 5 Electric Actuator Line-up of Products Short Stroke Electric Actuator Series LX Series LX Stepper motor High Rigidity Slide Table Type Series LXS Low Profile Slide Table Series LXF Guide Rod Type Series LXP P. 250 P. 210
" '&& &' & (& & )* Axial piping type (25): MXQ25L-P $ D-X !
The voltage (across P-N or P+-N-) of the main circuit converter is displayed. 0 to 900 V -79- 6. CC-Link setting CC-Link function of the driver. Wiring and PLC setting must to satisfy the specifications.
Weight[kg] Series LEKFS25 Stroke [mm] 50 100 150 200 250 300 350 400 450 500 600 700 800 S2 2.0 2.1 2.3 2.4 2.6 2.7 2.8 2.9 3.1 3.2 3.5 3.7 4.0 Motor type T6 2.1 2.2 2.4 2.5 2.7 2.8 2.9 3.0 3.2 3.3 3.6 3.8 4.1 Additional weight with lock [kg] 0.2 Series LEKFS32 Stroke [mm] 50 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 S3 3.4 3.6 3.8 4.0 4.3 4.5 4.7 4.9 5.1 5.3 5.8 6.2 6.6 7.1
401 to 500 77 90 102 115 140 165 190 88 101 113 126 151 176 201 Stroke Bore 32 20 12 35 30 10 M10 x 1.5 40 24 14 46 35 12 M12 x 1.75 Item I Wh Bore Stroke 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 57 70 82 95 120 145 170 64 77 89 102 127 152 177 32 12.5 25 37.5 50 75 100 125 40 12.5 25
401 to 500 77 90 102 115 140 165 190 88 101 113 126 151 176 201 Stroke Bore 32 20 12 35 30 10 M10 x 1.5 40 24 14 46 35 12 M12 x 1.75 Item I Wh Bore Stroke 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 57 70 82 95 120 145 170 64 77 89 102 127 152 177 32 12.5 25 37.5 50 75 100 125 40 12.5 25
. 10-12-8 P . 10-12-30 P . 10-12-18 P . 10-12-27 10-12-1 Achieve rationalization Stroke reading cylinder Measurement is possible throughout the full stroke range.
. 10-12-8 P . 10-12-30 P . 10-12-18 P . 10-12-27 10-12-1 2 Achieve rationalization of production lines with position feedback Stroke reading cylinder Measurement is possible throughout the full stroke range.
. 10-12-8 P . 10-12-30 P . 10-12-18 P . 10-12-27 10-12-1 2 Achieve rationalization of production lines with position feedback Stroke reading cylinder Measurement is possible throughout the full stroke range.
R V Front flange type (F)/CG5FNS GA GB FT 2-Rc P H1 Width across flats B1 D I AL A MM Width across flats NA K KA 8-J 4-FD C 0.1 S + Stroke ZZ + Stroke H M FX 0.15 B (mm) Stroke range A Bore size (mm) AL B1 B C D FX FD FT GA GB H H1 I J K KA M MM NA P S ZZ 20 to 350 18 15.5 13 50 16.5 8 36 5.5 6 18 12 35 5 31 M4 x 0.7 5 6 3 M8 x 1.25 29 1/8 83 121 25 to 400 22 19.5 17 50 18.5 10 36 5.5 6 18
, 450, 500, 600, 700, 800 25 4000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 32 5000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 40 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 6000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 63 Note1) Contact P/A in case of a stroke length beyond the maximum.
385 Max. speed[mm/s] 400 200 400 200 400 200 Pushing speed [mm/s] *2 35 or less 30 or less Actuator specifications Max. acceleration/deceleration[mm/s2] 5000 Positioning repeatability [mm] 0.01 Lost motion [mm] *3 0.1 or less Lead [mm] (including pulley ratio) 12 6 20 10 16 8 Impact/Vibration resistance [m/s2] *4 50/20 Ball screw Ball screw(In-line) Actuation type Belt[1.25:1] Ball screw
mass m (kg) 40 50 Larger than 75st 100 25st 50st 30 Larger than 50st 20 50 25, 50st 10 40 30 MGJ 5 4 3 20 MGP 2 10 1 MGQ 1 2 3 4 5 10 20 30 40 50 100 200 300 400 10 20 30 40 50 100 200 300 400 Eccentric distance l (mm) Eccentric distance l (mm) MGG MGC MGTL100 300 300 MGTM100 200 200 P = 0.5 MPa MGF 100 P = 0.5 MPa Larger than 75st Larger than 50st Load mass m (kg) Load mass m (kg) MGZ 40