The safety module achieves SIL 3, maximum. 68 44 Invalid parameterization of F_CRC_Length. The CRC length generated by the safety module (F-Module) does not match the required length. 69 45 Check device description. Invalid F_Parameter record version. The safety module (F-Module) version does not match the required version. Check device description.
DIP . 65 2 No.EX##-OMY0006CN 10.12. . 68 11. EX245-DX1 . 70 11.1. . 70 11.2. . 71 11.3. . 72 11.4. . 72 11.5. LED . 73 11.6. . 74 12. EX245-DY1 . 75 12.1. . 75 12.2. . 76 12.3. . 77 12.4. . 77 12.5. LED . 78 12.6. . 79 13. . 80 13.1. . 80 13.2. Y . 81 13.3. . 82 14. . 83 14.1. EX245-FPS1/2/3 . 83 14.2. . 85 15. . 86 15.1. EX245-FPS1/2/3 . 86 15.2. EX245-DX1 . 88 15.3.
F13 Setting for reverse display mode 45 F14 Zero cut-off setting 46 F30 Setting of accumulated value holding time 50 F80 Set display OFF mode 51 F81 Security code 52 F90 Setting of all functions 54 F96 Check of input signal 56 F98 Setting of output check 57 F99 Reset to the default settings 59 Other Settings 60 Maintenance 63 Forgotten the Security Code 63 Troubleshooting 64 Error display 68
OUT2 44 F3 Select digital filter 45 F6 Fine adjustment of display value 46 F13 Setting for reverse display mode 47 F14 Zero cut-off setting 48 F16 Measurement display setting 52 F30 Setting of accumulated value hold 53 F80 Set display OFF mode 54 F81 Security code 55 F90 Setting of all functions 57 F96 Check of cycle time 59 F98 Setting of output check 60 F99 Reset to the default settings 68
(100 ) :050 -5No.PF-OMO0007CN * (15 / ) FG 49 N () IN IN OUT OUT () IN () -6No.PF-OMO0007CN *) 6 33 2 () () 10 m DC(-)() () -7No.PF-OMO0007CN * ( ) () CE 050 -8No.PF-OMO0007CN * ON , 10 /23 3 OFF (19 ) * OUT -9No.PF-OMO0007CN (11 ) SI L/min L (11 ) 1/8 1/4 3/8 1/2 -10No.PF-OMO0007CN N (3 m) PF2A7--28--X560 NPN(1 )+ (15 V) PF2A7--29--X560 NPN(1 )+ (420 mA) 22 PF2A7--68
Check the flow characteristics data for pressure loss and the straight inlet pipe length effect on accuracy (page 68), to determine inlet piping requirements. Do not suddenly reduce the piping diameter. Piping port and the metal part of the body are grounded to DC(-)/blue line. Do not use the power supply with positive ground.
Operation of only the compressor stops when these Operation of both the compressor and pump stops when these alarms are generated. 5.22 Alarm Customizing Function HRSH Series 5-68 HRX-OM-Q026 Chapter 5 Display and Setting of Various Functions Setting/Checking: Operation setting when "Circulating fluid discharge pressure sensor error" alarm is generated 38. Press the [SEL] key once.
(Refer to page 68) For IP address setting, download the IP Address Setting Tool (EX9-ZSW-IPC1) from our website (URL https://www.smcworld.com) and configure settings.
Click Save. 68 - 5.10.2 To Load saved Point table From the Point table window in the setup software, select Open. Please specify location of the file. Please select the file you wish to import point table [.ptb2]. Click Open.
47 11.2 . 47 11.3 . 48 (1) . 48 (2) () . 48 (3) . 48 11.4 . 49 11.5 . 49 12() . 50 12.1 . 50 12.2 . 51 13 . 52 13.1 . 52 13.2 No. . 52 (1) . 52 [2] . 53 [3] . 54 [4](HOLD) . 54 [5] . 55 [6] . 55 (7) . 56 13.3 . 57 14. 58 14.1 [5m ] . 58 14.2 [820m] . 58 14.3 ()[5m ] . 59 15.4 ()[820m] . 59 14.5 . 60 14.6 . 60 14.7 . 60 -2- 14.8 . 61 15 . 62 15.1 IO . 62 15.2 . 63 16/ . 68
Item Decimal Common Format "Data-INT" "Data-SINT" Input 10 (words) 20 (bytes) Output 10 (words) 20 (bytes) Configuration 0 or 34 (words) 0 or 68 (bytes) : Set 0 for Configuration Size when configuration data setting is not changed from the default value. Configuration data setting will be explained later. Configuration data setting can be changed by setting 34 (words) or 68 (bytes).
Alarm Detection . 68 11.1 Alarm group output . 68 11.2 Alarm details . 69 12. Wiring of cables / Common precautions . 72 13. Electric actuators / Common precautions . 73 13.1 Design and selection . 73 13.2 Mounting . 74 13.3 Precautions for Use . 74 13.4 Operating environment . 76 13.5 Maintenance . 76 13.6 Precautions for electric actuator with lock . 77 14.
Coaxial tubing Branch tee: KWT04-S23 Branch Y: KWU04-S23 Coaxial tubing Marking/Finger closing side Coaxial tubing Single tubing Single tubing Single tubing Coaxial tubing Single tubing Single tubing Marking zFinger opening side 12-2-68 68 Parallel Style Air Gripper Long Stroke Type Series MHZL2 Axial Ported (with One-touch fitting) [K] (mm) Auto switch mounting groove (4 locations) (Except
NS 20 20 30 30 40 40 50 60 60 LT 58 58 68 68 78 78 88 98 108 LB 20 25 30 LA 10 10 20 20 30 30 20 25 30 J 4 4 4 4 4 4 6 6 6 Stroke (mm) 5 10 15 20 25 30 40 50 60 26 Compact Slide MXH Series Dimensions: 20 LT MXH MXH 20 31 MXS MXQ 14 LA LB J x M5 x 0.8 Depth 6.5 MXQ MXF 3 x M6 x 1.0 through 2 x 2 x M5 x 0.8 Cylinder port (With plug for port) MXW Pilot hole dia 5.1 2 x 3 x 9.3 counterbore depth
21.5 (14 port) 21.5 (12 port) 8.5 (2 port) 8.5 (4 port) 14 4 2 12 12 34 25 18 14 5 1 3 Indicator light 29.5 32.5 34 2-4.6 mounting holes 37 Manual override M8 connector 15.5 (12-, 14 port) 9 (2-, 4 port) 74.5 66.5 8.5 PE port 23 13.5 SMC 16 16 M5-2 ports 12, 14 port 1/8-2 ports 2, 4 port 1/8 1 port 1/8-2 ports 3, 5 port EVS1-02-FG-D-M0 EVS1-02-F G-D-M0 H J I 136 149 68 21.5 (14 port) 68
If screws other than those specified are used, it may cause the switch to be damaged. 3 41 41 38 5 68 68 63 Auto Switch Dimensions Unit: mm Auto switch internal circuits D-M9 Mounting screw M2.5 x 4 Slotted set screw D-M9N D-M9B, N, P Common DC (+) Brown [Red] Indicator light 2.6 Switch main circuit Switch main circuit Switch main circuit OUT Black [White] 2.7 2.8 4 22 DC (-) Blue [Black]
: (800) 258-9200-www.stevenengineering.com Model MHS MHL2-10D MHL2-10D1 MHL2-10D2 MHL2-16D MHL2-16D1 MHL2-16D2 MHL2-20D MHL2-20D1 MHL2-20D2 MHL2-25D MHL2-25D1 MHL2-25D2 MHL2-32D MHL2-32D1 MHL2-32D2 MHL2-40D MHL2-40D1 MHL2-40D2 280 345 425 585 795 935 1025 1495 1690 1690 2560 2775 2905 3820 4655 5270 6830 7905 76 118 156 98 170 210 122 222 262 150 282 320 220 318 402 288 406 486 56 78 96 68
Coaxial tubing Branch tee: KWT04-S23 Branch Y: KWU04-S23 Coaxial tubing Marking/Finger closing side Coaxial tubing Single tubing Single tubing Single tubing Coaxial tubing Single tubing Single tubing Marking zFinger opening side 12-2-68 68 Parallel Style Air Gripper Long Stroke Type Series MHZL2 Axial Ported (with One-touch fitting) [K] (mm) Auto switch mounting groove (4 locations) (Except
End plate ass'y 1 pc. 1.5-26 ARM2500/3000 Dimensions Dimensions B C D E F G H I J K L M N O P Symbol Model A ARM2500 ARM3000 6 17 44 56 42 126.5 58 45 17 21 38 42 29 48 68 33.5 7 21 54 68 55 153.5 70 53 23.5 27.5 48.5 55 35 59 85.5 42.5 Manifold stations Dimensions by Number of Stations 10 Model Symbol 9 8 7 6 5 4 3 2 454 412 370 328 286 244 202 160 118 L1 ARM2500 442 400 358 316 274 232
Data Symbol Specifications Anti-corrosive specifications for guide unit (N) -X42 Operating pressure (MPa) Bore size (mm) Rod size (mm) Operating direction Piston area (mm2) 0.7 0.6 0.5 0.4 0.3 0.2 71 61 51 40 30 20 101 R 4 8 53 45 38 30 23 15 75 L 158 136 113 90 68 45 226 R 6 12 119 102 85 68 51 34 170 L 281 241 201 161 121 80 402 R 8 16 211 181 151 121 91 60 302 L 440 377 314 251 188 126