How to Order B 20 30 D C CQSY Without auto switch F9BW S B 20 30 D C CDQSY With auto switch Number of auto switches Built-in magnet 2 pcs. 1 pc. n pcs.
) Stroke range (mm) C D E F H I J K L M N O P Q S U Z A B A B 46 10 to 50 54 14 depth 10.5 63 64 56 15 20 77 10.5 M10 x 1.5 103 7 17 8 60 9 1/4 15 93 47.5 19 56 75, 100 64 53.5 10 to 50 63.5 17.5 depth 13.5 80 73.5 63.5 21 25 98 12.5 M16 x 2.0 132 6 22 10 77 11 3/8 16 112.5 57.5 26 63.5 75, 100 73.5 63 10 to 50 75 17.5 depth 13.5 100 85 73 27 30 117 13 M20 x 2.5 156 6.5 27 12 94 11 3/8 23
Mounting Bolt for C55 Model C D Mounting bolt Model C D Mounting bolt Model C D Mounting bolt C(D)55B20-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B25-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B50-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B63-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B32-5 -
(c)BUSY ONINP OFF No. () (d)INP ONBUSY OFF INP ON BUSY OFF (INP ONBUSY OFF) 2 ABS 75 No.SFOD-OMT0009CN-B (3) --(a)No.(INx) (b)DRIVE ON Min.15ms No.(OUTx ) No. No. (c)BUSY ONINP OFF (d)INP ON 2.5[s] ALARM ON( ) BUSY OFF INP ON BUSY OFF 1)(0-149) 2)(d) 2 ABS 76 No.SFOD-OMT0009CN-B (4) HOLD --(a)(BUSY ON)HOLD ON (b)BUSY OFF () No. (c)HOLD OFF No.
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Air cushion, Operating Pressure(MPa)
Magnet: D (Built-in), Mounting: B (Basic Style), Cushion: A (Non-lube Air Cushion), Bore Size: 25mm, Port Thread: Rc, Stroke: 200mm, Rod Boot: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)
Magnet: D (Built-in), Mounting: F (Front Flange), Cushion: A (Non-lube Air Cushion), Bore Size: 25mm, Port Thread: Rc, Stroke: 400mm, Rod Boot: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)
Magnet: D (Built-in), Mounting: F (Front Flange), Cushion: A (Non-lube Air Cushion), Bore Size: 20mm, Port Thread: Rc, Stroke: 200mm, Rod Boot: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)
Magnet: D (Built-in), Mounting: B (Basic Style), Cushion: A (Non-lube Air Cushion), Bore Size: 32mm, Port Thread: Rc, Stroke: 250mm, Rod Boot: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)
Magnet: D (Built-in), Mounting: B (Basic Style), Cushion: A (Non-lube Air Cushion), Bore Size: 40mm, Port Thread: Rc, Stroke: 150mm, Rod Boot: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)
Magnet: D (Built-in), Mounting: B (Basic Style), Cushion: N (Non-lube Rubber Bumper), Bore Size: 32mm, Port Thread: Rc, Stroke: 200mm, Rod Boot: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Air cushion, Operating Pressure(MPa)
Magnet: Built-in, Mounting: Basic Style, Cushion: Non-lube Air Cushion, Bore Size: 25mm, Port Thread: Rc, Stroke: 200mm, Rod Boot: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: Auto Switch Mounting Bracket
Magnet: Built-in, Mounting: Front Flange, Cushion: Non-lube Air Cushion, Bore Size: 20mm, Port Thread: Rc, Stroke: 200mm, Rod Boot: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: Auto Switch Mounting Bracket
Magnet: Built-in, Mounting: Basic Style, Cushion: Non-lube Air Cushion, Bore Size: 32mm, Port Thread: Rc, Stroke: 250mm, Rod Boot: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: Auto Switch Mounting Bracket
Magnet: Built-in, Mounting: Basic Style, Cushion: Non-lube Air Cushion, Bore Size: 40mm, Port Thread: Rc, Stroke: 150mm, Rod Boot: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: Auto Switch Mounting Bracket
Magnet: Built-in, Mounting: Basic Style, Cushion: Non-lube Rubber Bumper, Bore Size: 32mm, Port Thread: Rc, Stroke: 200mm, Rod Boot: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: Auto Switch Mounting Bracket
r^rE_aEIl_I ItrtrElEll+trMElr cG1 C D G l T T series i I .2: 3. .4, i.5. .6-l '?
Booster regulator IN port C ARX EXH: C EXH: C Spare port Rc1/2 (A) AMR D D (A) (B) (B) OUT OUT 305 Tank OUT port Rc1/2 ARM 216 216 180 4 x 13 4 x 13 50 50 ARP Drain valve 100 100 Drain port Rc1/4 IR-A 200 200 400 700 678 IR Booster regulator model A B C D VBA20A 481 394 Rc3/8 VBA40A 520 429.8 Rc1/2 VBA22A 444 394 Rc3/8 469 VBA42A 477 429.8 Rc1/2 493 IRV The length may be longer than the