SMC Corporation of America
Elite Part Number Search
Search Results "CDNGFA32-400-D-M9BAV-C"

D) In the state of C), adjust shim w so that the arm side block contacts the workpiece. E) Exhaust the air while in the clamped state, and confirm that the clamp arm does not open. 8 CKZT -X2797 -X2798 Relation between shim thickness and clamping force Use this figure as a guide, as there is a tolerance of about 10% in the clamp cylinder body.

Note 1) 20 16 17 Elbow for piping port/IZN10D B C 180 10 (mm) B Model C 16 D 11.5 IZN10-16 (mm) IZN10-17 (inch) 22 24.5 18.5 12 Female threads for piping (Rc1/8)/IZN10-11 16 Rc1/8 13 Width across flats 14 456 Ionizer IZN10 Series Dimensions L-bracket/IZN10-B1 IZS (Mounting angle adjustable range) 40 7.5 17 IZN IZN 2 x R10 3.4 2 x M3 2 x 3.4 IZF 25 40 5 ZVB 50 Internal mounting IZD IZE 20.5

K J H G F E D C B A 475 432 512 472 525 482 562 522 L Booster part no. Tank model VBA2100-03 VBA2200-03 VBA4100-04 VBA4200-04 VBA2100-03 VBA2200-03 VBA4100-04 VBA4200-04 394 Rc 3/8 VBAT20 VBAT20S 305 206 674 180 200 100 400 Rc 1/2 430 Rc 1/2 444 Rc 3/8 VBAT38 VBAT38S 355 256 824 205 250 150 500 Rc 3/4 480 Rc 1/2 14-9-9

D U 25 Approx. 44 R C C R G1/2 E E G1/2 B B 2-P Port size A A D 2-P Port size (S) Port size G1/2 Compatible heavy duty cord Cable O.D. 6.8 to 10 L L K 2-M Thread depth 6 K 2-M Thread depth 6 (mm) Electrical entry P Port size B C Model A D E F K L M Grommet: G Conduit: C DIN connector: D Conduit terminal: T U 81 91.5 101 103.5 Q 98 101 104 104 R 36 44 53 55.5 S 68 71 74 74 Q 46 50 52 52 R

(for 2000 L/min) 50 50 50 Supply pressure 200 kPa Supply pressure 400 kPa Supply pressure 200 kPa Supply pressure 400 kPa 40 40 40 Pressure loss [kPa] Pressure loss [kPa] Pressure loss [kPa] Supply pressure 200 kPa Supply pressure 400 kPa 30 30 30 20 20 20 10 10 10 0 0 0 0 400 800 1200 1600 2000 0 100 200 300 400 500 0 200 400 600 800 1000 Flow [L/min] Flow [L/min] Flow [L/min] IN Side Straight

screw D-B5/B64 D-B59W D-G5NTL D-G5NBL BA-01 BA-02 BA-32 BA-04 Cylinder tube BD1-01M BD1-02M BD1-02 BD1-04M D-A3/A44 D-G39/K39 qBMA2-: A set of a and b in the figures. wBJ3-1: A set of c, d and e in the figures.

screw D-B5/B64 D-B59W D-G5NTL D-G5NBL BA-01 BA-02 BA-32 BA-04 Cylinder tube BD1-01M BD1-02M BD1-02 BD1-04M D-A3/A44 D-G39/K39 qBMA2-: A set of a and b in the figures. wBJ3-1: A set of c, d and e in the figures.

CE2 ML2B ML1C Mounting Position (Stroke End)/Reed Switch Mounting Position (Stroke End)/Solid State Switch D-E73A (L), D-E76A (L), D-E80A (L) D-M5B (L), D-M5N (L), D-M5P (L) D-M5BW (L), D-M5NW (L), D-M5PW (L) D-M5NTL, D-M5PTL REA REC RHC MTS CC Lead wire clamp/Lead wire cap (option) Series Lead wire clamp Lead wire cap ML1C LC-01 LP-01 Unit: mm Lead wire clamp/Lead wire cap (option) 25 32

D-A9V 10 6 6 8.5 10 D-M9 D-F9W D-M9V D-F9WV 5.5 (4) 3 (2) 3 (3) 4 (3) 6 (4) Interference Note) Figures in parentheses are the case for D-M9, D-M9V switch types.

Part No. 25 350, 400, 450, 500 75, 100, 125, 150, (Band and screw are included.) 32 350, 400, 450, 500, 600 Ball bushing bearing MLGCL 200, 250, 300 Bore size (mm) Auto switch model D-C7/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 40 350, 400, 450, 500, 600, 700, 800 20 25 32 40 BMA2 -020 BA -01 BA -02 BA -32 BA -04 BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other

Part No. 25 350, 400, 450, 500 75, 100, 125, 150, (Band and screw are included.) 32 350, 400, 450, 500, 600 Ball bushing bearing MLGCL 200, 250, 300 Bore size (mm) Auto switch model D-C7/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 40 350, 400, 450, 500, 600, 700, 800 20 25 32 40 BMA2 -020 BA -01 BA -02 BA -32 BA -04 BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other

MXQ MXF MXW MXP MG MGP MGQ MGG MGC MGF CY1 MY1 3.2-9 Series MLGC Proper Mounting Positions of Auto Switch (Stroke End) D-C7/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 Setting Positons of Auto Switch Mounting Height of Auto Switch (mm) (mm) Model D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-H7C D-G5/K5 D-G5lW D-K59W D-G5NTL D-B5/B6 D-B59W D-G5BAL D-G59F D-B5/B6 D-G5lW D-K59W D-G5BAL D-G59F D-B7/B8

-X 20Hv Data Proper Auto Switch Mounting Position Solid state switch Bore size (mm) 2-color indication solid state switch Reed switch D-A9 D-A9V D-M9 D-M9V D-F8 D-F9W A B Hv D-F9WV A B C A B Hv A B C A B Hv A B Hv A B C 36 25 16 36 25 15 32 21 20 32 21 17.5 18 7 25 32 21 20 32 21 17.5 8 Auto Switch Mounting Stroke for 8 Stroke (mm) Note Applicable auto switch Mounting condition Piping direction

Dimensions [Separately installed power transformer] C E IDF-TR7000-8 G B D 4 x F A Specications/Dimensions in (mm) Transformer Applicable dryer Capacity Type Inlet voltage Outlet voltage A B C D E F G Weight 14.2 (360) 21.3 (540) 15.7 (400) 10.2 (260) 11.8 (300) 0.43 (11) 1.18 (30) 207 lb (94 kg) IDF-TR7000-8 IDF100FS 7 kVA Three-phase Compound winding 220, 240 380, 400, 415 440 V (50/60

KF ) Fn J H B A G A mm A B C D E Fn G H J XLC-16 40 110 38 1 30 17 40 26 XLC-25 50 120 48 1 12 40 26 39 27.5 XLC-40 65 171 66 2 11 55 41 63 36 9 XL-OMV0002 4-2.162580,100,160 C E D C E E (KF ) (K ) Fn Fd J K H B A G A mm A B C D E Fn Fd G H J K XLC-50 70 183 80 31 10.5 75 52 77 29 10.5 XLC-63 88 209 100 39 11 87 95 70 76.5 36 9 XLC-80 90 250 117 45.5 11 114 110 83 105 44 9 XLC-100 108 317.5

pressure P2 [MPa] 0.9 MPa 0.7 Critical pressure Subsonic 0.8 MPa 0.6 0.7 MPa 0.6 MPa 0.5 0.5 MPa 0.4 Sonic 0.4 MPa 0.3 0.3 MPa 0.2 0.2 MPa 0.1 0.1 MPa 0 VXB215 A D(H) 100 300 400 200 VXB215 B E(H) 100 300 400 500 600 200 VXB215 C F(H) 100 300 400 500 600 700 800 200 Flow rate Q [kg/h] How to read the graph The sonic range pressure to generate a flow rate of 300 kg/h is P1 0.3 MPa for the

Proper auto switch mounting position A B Auto switch model D-Y5 D-Y6 D-Y7P D-Y7PV D-Y5 D-Y6 D-Y7P D-Y7PV D-Z7 D-Z80 D-Y7W D-Y7WV D-Y7W D-Y7WV D-Z7 D-Z80 Cylinder model CYP15 93.5 24.5 CYP32 122 33 Auto Switch Mounting When mounting auto switches, they should be inserted into the cylinder's switch groove from the direction shown in the drawing on the right.