Magnet: Built-In, Mounting: Basic Style, Style: Non-lube Air Cushion, Bore Size: 50mm, Thread: Rc (or M5 Depending on Style, Bore Size, and Thread Combinations), Piping: Screw-in Piping, Stroke: 100mm, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case
Magnet: Built-in, Mounting: Basic Style, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Air Pressure Lock-up, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewied Connector: 3m, Number: -
Clevis Width: 12mm, ø32; 16.5mm, ø40, 50, 63, Bore Size: 63mm, Port Type: Rc1/4, Stroke: 100mm, End Bracket: None, Option: None, Locking Direction: Retraction Locking, Unlock Port Position: Top (Retraction Locking: No; Extension Locking: Yes), Switch Mounting Rod Position: Top, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number
Clevis Width: 12mm, ø32; 16.5mm, ø40, 50, 63, Bore Size: 40mm, Port Type: Rc1/4, Stroke: 100mm, End Bracket: None, Option: None, Locking Direction: Extension Locking, Unlock Port Position: Top (Retraction Locking: No; Extension Locking: Yes), Switch Mounting Rod Position: Top, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number
Bore Size: 12mm, Thread Type: Bore 8-16: M Thread, Bore 20-25: Rc, Stroke: 100mm, Option: Standard (w/Urethane Bumper), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Basic Style, Style: Non-lube Air Cushion, Bore Size: 32mm, Stroke: 100mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Rubber Bumper, Bore Size: 40mm, Stroke: 100mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: Rc, Auto Switches: M9BW,
Magnet: Built-in, Mounting: Through Hole, Overall Length: Standard, Bore Size: 1 1/2", Stroke: 1", Body Option: Standard (Rod End Female Thread), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: None, Speed Control Type: Right Angle, Applicable Tubing: 5/32", Suffix: Required Selection
Mounting: Front Flange, Bore Size: 40mm, Thread: Rc, Stroke: 100mm, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Speed Control Type: Right Angle, Applicable Tubing: 06mm, Suffix: Required Selection w/Speed Control
Mounting: Basic Style, Bore Size: 25mm, Thread: NPT, Stroke: 100mm, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Speed Control Type: Right Angle, Applicable Tubing: 1/4", Suffix: Required Selection w/Speed Control
Mounting: Front Flange, Bore Size: 25mm, Thread: NPT, Stroke: 100mm, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Speed Control Type: Right Angle, Applicable Tubing: 1/4", Suffix: Required Selection w/Speed Control
Bearing Style: Slide Bearing, Mounting: Basic, Bore Size: 25mm, Thread: Rc, Stroke: 100mm, Lock Position: Rear Locking, Release of Manual: Non-locking Type, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Bearing Style: Ball Bush Bearing, Mounting: Basic, Bore Size: 20mm, Thread: Rc, Stroke: 100mm, Lock Position: Rear Locking, Release of Manual: Non-locking Type, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Mounting: Foot, Bore Size: 32mm, Thread: Rc, Full Stroke: 100mm, First Stroke: 50mm, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Bore Size: 12mm, Thread Type: Bore 8-16: M Thread, Bore 20-25: Rc, Stroke: 100mm, Option: Standard (w/Urethane Bumper), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Double acting, single rod cylinder w/lock, Mounting: basic, axial foot, rod flange, head flange, single clevis, double clevis, center trunnion, Bore sizes (mm): 40, 50, 63, 80, 100, Strokes up to 1500mm (depending on bore size and mounting), Auto switch capable, CYL, TIE ROD, POWER LOCK, A/S, ACTUATOR, CNA/CNA2 POWER LOCK CYLINDER, NE, 50MM CNA DBL ACTING, AUTO-SW, 8.37756 lb
Band Mount: None, Rail Mount: None, Tie-rod Mount: None, Direct Mount: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire: 3m, Option: Compatible w/90-
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No