Note 3) Bore size determination E Es NG Determination of allowable stroke (W + WB) V 2 E = x ( ) 2 1000 E Es Note 2) OK Determination of pressure (P) when making intermediate stop Review of order made products based on operating conditions P Ps DNote 1) This cylinder cannot perform an intermediate stop using an air pressure circuit in vertical operation.
Compact Type: CXSJ Vertical mounting L L Mounting orientation m m Maximum speed (mm/s) up to 600 up to 800 up to 400 up to 200 Stroke (mm) All strokes 6 10 Selection graph 1 2 3 4 Horizontal mounting L Mounting orientation m m Refer to the caution notes below. up to 800 up to 400 up to 800 up to 400 up to 400 up to 800 up to 400 up to 800 up to 50 up to 75 up to 10 up to 30 Stroke (mm) Maximum
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Construction Individual exhaust spacer Gasket Spacer E M2.5 x 36 (2 pcs.)
1600 0 200 400 600 800 1000 1200 1400 1600 Stroke [mm] Stroke [mm] [Graph 7] Allowable load mass by stroke 40 100 y, z + A = 0 y, z + A = 50 Load mass [kg] y, z + A = 100 y, z + A = 200 10 y, z + A = 300 1 0 200 400 600 800 1000 1200 1400 1600 If load center of gravity exceeds the value of y, z + A on the graph, please consult SMC.
Proceed with caution. 2000 mm or more 400 mm or more 800 mm or more 800 mm or more 800 mm or more Ventilation HRL -A -20 3. If it is impossible to exhaust heat from the installation area indoors, or when the installation area is conditioned, provide a duct for heat exhaustion to the air outlet port of this product for ventilation.
MVAny MVtype Valve will work here, set up Normally Open E SCS-112 1/8 Stroke Completion Sensor (SCS) SCS-250 SCS SCS-375 3/8 SCS SCS-500 SCS www.poweraire.com 1-800-526-7661 22 Section III: Circuits Two Hand Extend Two Hand Retract Use this circuit, where a pinch point exists on both the extension and retraction of the linear actuator.
MVAny MVtype Valve will work here, set up Normally Open E SCS-112 1/8 Stroke Completion Sensor (SCS) SCS-250 SCS SCS-375 3/8 SCS SCS-500 SCS www.poweraire.com 1-800-526-7661 22 Section III: Circuits Two Hand Extend Two Hand Retract Use this circuit, where a pinch point exists on both the extension and retraction of the linear actuator.
Series IDUS Air Dryer Stainless Steel Heat Exchanger Type IDUS3E/4E/6E Evaporation thermometer G H Illumination switch Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com J K Draft air outlet A B D E Power cord outlet Air outlet Air inlet 22 C Draft air inlet F L 16 M
5 e r t q w @9 @4 MX @2 MTS CXTM Guide rod/bearing @8 MY CY @5 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX CXTL Guide rod/bearing D@1 -X 20@6 Data !9 @7 !2 y !3 u o !8 !0 !7 !6 Component Parts Description Material Note No.
OR-1860-120F F: FKM E: EPDM For VCB30 OR-2380-130F F: FKM E: EPDM For VCB40 OR-2600-180F F: FKM E: EPDM e When external leakage occurs after disassembling a valve, replace the above seals.
7 q e @0 !0 o @2 @3 !5 u t !8 @1 r @4 w MX MTS MY 12 to 40 CY @7 !1 !7 q !6 !0 @2 @3 o @4 @6 y e r !
bore 1/8 R 4-R 4-R 36.8 E 36.8 E R P VEX P D D AMR + + MADE IN JAPAN ITV MADE IN JAPAN SMC SMC IC VBA Model Port size A B C D E G H I VE K L M N P Q R AV2000-02-G AV2000-02-GS AV2000-02-D AV2000-02-DZ AV2000-02-Y AV2000-02-YZ AV3000-03-G AV3000-03-GS AV3000-03-D AV3000-03-DZ AV3000-03-Y AV3000-03-YZ AV4000-04-G AV4000-04-GS AV4000-04-D AV4000-04-DZ AV4000-04-Y AV4000-04-YZ AV5000-G AV5000
G H AV OUT port AU AF 4-12 mounting hole Silencer (Option) O EXH port: 1 position AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com F EXH port: 1 position D E IR A 300 404 B 126.5 167 C 53 96 D 73 116 E 118 150 F 98 130 G 46 62.8 H 43 62 I 60.5 90 J 18 17 K 15 15
0 t t r i u w y e q r i w e q VQ7-8-FG-DVQ7-8-FG-D-R !0 !0 t t r i w y e q r i w e q VQ7-8-D-R FHG FJG FIG VQ7-8-DFHG FJG FIG !0 !0 t t r i w y e q r i w e q VQ7-8-FPG-D!0 t r i w y e q o Replacement Parts (For valve) Description VQ7-8-FG-SVQ7-8-FG-DVQ7-8-FPG-DVQ7-8-FG-S-R VQ7-8-FG-D-R VQ7-8--D-R VQ7-8--DNumber q w e r t y u i o !
Unit psig/bar MPa Code r e No code MPA Sample Order Number Port qIN wOUT eGauge port (Inlet) rGauge port (Outlet) w q AZ1402TS e q FV4 FV4 FV4 FV4 w FV4 FV4 FV4 FV4 r 3) Pressure gauge unit MPa or psig/bar selectable.
Bore si~e ~ Standard stroke (mm) .
Type T: 4.5 to 7 mm Type E: 2.3 to 2.8 mm Type D: 6 to 8 mm Applicable crimp terminal Type E/T: 1.25-3, 1.25-3S 1.25Y-3N, 1.25Y-3S Round or Y shaped crimped terminals can be not used for type D.
Water hammer relieving Check valve mechanism is provided in the E side of the supply orifice D and E and supply into the pressure action chamber B can be controlled with two stages by moving the diaphragm assembly r. After release of the energy, when the open amount of the main valve C becomes small, E is blocked. A low valve closing speed relieves the water hammer.
Local Area: (800) 258-9200-www.stevenengineering.com Label Model Connection (Flange) 2B 2B, 3B, 4B 400 A 280 B 760 D 150 E 270 F 1033 G 3 H 887 J 6B C 620 AMD801 AMD901 445 795 300 520 1318 3 972 12B AMD800/900/1000 ORIENTATION holes Label Drain Model Connection (Flange) 2B, 3B 8B C 2B, 3B, 4B 500 A 300 B 300 D 1300 E 1430 F 1520 G 20 H 720 M16 x l 400 Anchor bolt M20 x l 500 AMD800 AMD900
(650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Model Connection (Flange) 2B 2B, 3B, 4B 400 A 280 B 6B C 550 D 150 E 270 F 823 G 3 H 797 J 620 AMF801 AMF901 445 12B 570 300 520 1093 3 867 AMF800/900/1000 ORIENTATION holes Label Drain Model Connection (Flange) 2B 8B C 2B, 3B, 4B 500 A 330 B 300 D 1070 E 1200 F 1290 G 20 H 720 M16 x l400 Anchor bolt M20 x l500 AMF800