SMC Corporation of America
Elite Part Number Search
Search Results "CDLA2F63TN-250-D"

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 63mm, Thread: NPT, Stroke: 600mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewied Connector: 1.0m Cord Length, M12-4 Pin Connector, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 63mm, Thread: NPT, Stroke: 600mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewied Connector: 1.0m Cord Length, M12-4 Pin Connector, Number: 1 pc.

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 63mm, Thread: NPT, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewied Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 63mm, Thread: NPT, Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewied Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 63mm, Thread: NPT, Stroke: 150mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewied Connector: 3m, Number: 1 pc.

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 63mm, Thread: NPT, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 63mm, Thread: NPT, Stroke: 350mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: M9PWV--Solid State, 2-color Indication, 3 Wire PNP, Vertical, Lead Wire or Prewied Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 63mm, Thread: NPT, Stroke: 75mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewied Connector: -, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 63mm, Thread: NPT, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: M9PWV--Solid State, 2-color Indication, 3 Wire PNP, Vertical, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 63mm, Thread: NPT, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: F5P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewied Connector: 0.5m (Or None in the Case of No Switch), Number: 3 pcs.

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 63mm, Thread: NPT, Stroke: 400mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: G5P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewied Connector: 3m, Number: 1 pc.

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 63mm, Thread: NPT, Stroke: 450mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: J59W--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 63mm, Thread: NPT, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: J59W--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewied Connector: 3m, Number: -

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 63mm, Thread: TN (NPT), Stroke: 600mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewied Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 63mm, Thread: TN (NPT), Stroke: 800mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock), Auto Switch: M9PWV--Solid State, 2-color Indication, 3 Wire PNP, Vertical, Lead Wire or Prewied Connector: MDPC (1.0m Cord Length, M12-4 Pin Connector)

DC specifications of type "D" and "DO" is only available with 12 and 24 V DC.

C D 15 (mm) Auto switch model A D-F9 B C D D-A9 D-F9 D-A9 D-F9 D-A9 D-F9 Bore size (mm) 17.5 15 D-A9 21.5 76.5 72.5 56.5 60.5 Note) Auto switches cannot be installed in Area C in the case of 15. 25, 32 (mm) A D-Y5 D-Y7 D-Y7W B C D Auto switch model D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 Bore size (mm) 25 22 101 103 47 47 78 78 22 32 30.5

0 50 100 150 200 250 Supply pressure (kPa) Supply pressure (kPa) Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 0.6 0.4 0.5 mm 0.25 mm 0.5 Detection distance (mm) Detection distance (mm) 0.3 0.4 0.3 0.2 0.15 mm 0.2 0.15 mm 0.1 0.1 0.03 mm 0.01 mm 0 0 0 50 100 150 200 250 0 50 100 150 200 250 Supply pressure (kPa

It is already built-in to the rectifier circuit. 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 3 4 220 VAC 50/60 Hz [230 VAC 50/60 Hz] Electrical entry D With connector DIN terminal DC specifications of type D and DO is only available with 12 and 24 VDC. Power saving circuit is not available in the case of D or DO type.