'-02 ~2 06 >6 (Application: Refer to ListO) i 08 ~8 U Flat type Material a With buffer 04 4 Pad type.
Precautions FH100-06 to 24: Nominal filtration 10 m q Mounting Confirm IN and OUT before mounting.
As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.
As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.
As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.
As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.
As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.
Load factor: ((Load weight x 9.8)/Theoretical force) x 100% Conditions Series CJ2 Series CM2 6 x 1 m AS3301F-06 12 x 1 m AS4001F-12 AN200-02 AS2301F-06 AN110-01 Series MB/CA2 Series CJ2 Series CM2 Series MB/CA2 Body ported Tubing bore x Length Speed controller Silencer Base mounted Tubing bore x Length Speed controller Silencer AN200-02 AN3301F-06 AS1301F-06 6 x 1 m AS3001F-06 SYJ7120-01
AL10, 20 AL30, 40, 40-06 AL50, 60 1 8 Body Zinc die-cast Aluminum die-cast Platinum silver Housing Platinum silver Aluminum die-cast Replacement parts Part no. Material Description No.
3/4 1 Thread type ON-flow range Note 1) IF30 is available for 06.
Size: 1/8, Reverse Flow: Regulator w/Backflow Mechanism, Thread: M Thread, Rc(PT), Port Size: 1/8, Accessory: Round Pressure Gauge, Option 1: 0.02~0.2MPa Setting, Option 2: -
Size: 1/8, Reverse Flow: Regulator, Standard, Thread: M Thread, Rc(PT), Port Size: 1/8, Accessory: Round Pressure Gauge, Option 1: 0.02~0.2MPa Setting, Option 2: -
Size: 1/8, Reverse Flow: Regulator, Standard, Thread: M Thread, Rc(PT), Port Size: 1/8, Accessory: Round Pressure Gauge, Option 1: Non-relieving, Option 2: -
Size: 2 (Size 2000 Flow 240Nl/min), Stations: 6 Stations, Piping Specification: A1 (IN: Common OUT: Manifold), Thread: Rc(PT), Accessory: G (Pressure Gauge)
Size: 1 (Size 1000, Flow 100Nl/min), Stations: 4 Stations, Piping Specification: B2 (IN: Individual OUT: Main Body), Thread: Rc(PT), Accessory: G (Pressure Gauge)
Body Size: IR1000, Type of Setting: 0 [Basic (Handle)], Set Pressure: 2 [0.005~0.8MPa (IR1000/2000) or 0.01~0.8MPa (IR3000)], Thread: Rc(PT), Port Size: 01 [1/8 (IR1000 Only)], Accessory: Pressure Gauge, Temperature Environments: Standard, Suffix: Opposite Side Mounting of Pressure Gauge, Bracket, Name Plate, Made to Order: -
Body Size: IR1000, Type of Setting: 0 [Basic (Handle)], Set Pressure: 0 [0.005~0.2MPa (IR1000/2000) or 0.01~0.2MPa (IR3000)], Thread: Rc(PT), Port Size: 01 [1/8 (IR1000 Only)], Accessory: Pressure Gauge, Temperature Environments: Standard, Suffix: None, Made to Order: Compatible with Modular Connection Brackets
Body Size: IR1000, Type of Setting: 0 [Basic (Handle)], Set Pressure: 2 [0.005~0.8MPa (IR1000/2000) or 0.01~0.8MPa (IR3000)], Thread: Rc(PT), Port Size: 01 [1/8 (IR1000 Only)], Accessory: Pressure Gauge, Temperature Environments: Standard, Suffix: None, Made to Order: Non-grease Specifications
Size: 20, Backflow Function: K (Backflow Function), Thread: Rc, Port Size: 01 (1/8), Accessory: G (Round Pressure Gauge w/Limit Indicator), Specifications: 1 (0.005 to 0.2 MPa Setting)
Size: 20, Backflow Function: None, Thread: Rc, Port Size: 01 (1/8), Accessory: G (Round Pressure Gauge w/Limit Indicator), Specifications: 3 (0.008 to 0.6 MPa Setting)