SMC Corporation of America
Elite Part Number Search
Search Results "AL40-04-2-A"

2 AS420-04-SD Rc 1/2 24 R 1/2 12.4 38.5 27.5 28.5 63.8 26.7 1.2 55.8 Reference thread dimensions after installation. 15-9-91

L ZY O L ZF G H F ZP K J SP ZCUK B C E D I A 2 x 4.5 AMJ AMV AEP HEP Related Equipment A B C D E F G H I J K L Model ZFC050-02 ZFC050-23 ZFC050-04 ZFC051-01 ZFC051-03 58.5 12.75 12.75 2 3.2 4 33 25 10 10.5 10.5 12 8.5 13.75 58 12.5 12.5 1/8" 5/32" ZFC100-04 4 ZFC100-06 6 53.2 9.1 14.1 30 10 18 11.6 19.5 23 20 29 ZFC101-03 5/32" ZFC101-07 1/4" ZFC200-06 6 ZFC200-08 8 67 15.5 17.5 34 14 22

R 02 2 04 4 06 6 08 8 10 10 13 13 16 16 20 20 25 25 32 32 40 40 50 50 M O U N T I N G T H R E A D P A D T Y P E Symbol Thread Dia 2~8 10~16 40~50 20~32 U Flat C Flat with Rib (Not 2,4,6,8) D Deep (10,16,25,40) B Bellows (Not 2,4) A5 M5X0.8 Male Thread A6 M6X1 A8 M8X1 V A C U U M E N T R Y Symbol Port Size 2~8 10~16 40~50 20~32 P A D M AT E R I A L 04 4 tube OneTouch Tube Fitting N Nitrile

23.8 NPT 1/2 AS420-F04-SD G 1/2 AS420-04-SD Rc 1/2 24 27.5 R 1/2 28.5 12.4 38.5 62.9 25.8 1.2 55.8 222 Reference thread dimensions after installation. 751

Applicable for pressure detection with a wide range of fluids, by using a stainless steel diaphragm. 16-2-25 2 Pressure detection for a wide range of fluids.

SOL. location A B A B A B A B () A B () () 0 1 2 3 4 5 6 Double Double Single SI unit A side B side 3 position A B A B B A B A B A VQC Double Double Single SI unit A side B side 3 position Stations 1 2 3 4 5 SQ The places of asterisk are not used. 3 position uses two stations for wiring.

D2 D3 L1 L2 L3 L4 M1 L5 Weight T D1 H(1) D2 D3 L1 L2 L3 L4 M1 L5 H(1) A(2) A(2) AQ Weight (g) (g) Model Min.

A Contact output 1 selected alarm Sets alarm which is selected for contact output 1. AL.01 Contact output 2 function Sets output signal function of contact output 2. RMT Contact output 2 operation Sets output signal operation of contact output 2. A Contact output 2 selected alarm Sets alarm which is selected for contact output 2.

Body class 2 Connecting tubing O.D. Symbol A R P 4 Metric sizes 03 04 06 3 4 6 Valve type N.C. 0 N.C.

A Contact output 1 selected alarm Sets alarm which is selected for contact output 1. AL.01 Contact output 2 function Sets output signal function of contact output 2. RMT Contact output 2 operation Sets output signal operation of contact output 2. A Contact output 2 selected alarm Sets alarm which is selected for contact output 2.

, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 86.3 78.3 2(A) 2(A) 63 19 (A port) Rc 1/2 Individual exhaust: VV3PA7-42Station 3-04 (R port) Rc 1/2 34 3(R) 3(R) PA NO NC 112 (Mounting hole) 2-8.5 40 PA 52 119.5 112.5 86 1(P) 119.5 24 52 PA (P port) Rc 1/2 (Pitch) 41 37 (PA port) Rc 1/8 112.8 8 L2 L1 (PA port) Rc

-A-10, HRSE018-A-10) 8.5.2 HRSE012/018/024-A-20/23 0.14 14 0.12 12 Circulating fluid pressure [MPa] Outlet : 60Hz 10 0.10 Pump head [m] 8 0.08 Outlet : 50Hz 0.06 6 0.04 4 Available area Return port 0.02 2 0.00 0 2 4 6 8 10 12 14 16 Circulating fluid flow [L/min] Fig. 8.5-2 Pump capacity (HRSE012-A-20/23, HRSE018-A-20/23, HRSE024-A-20/23) HRSE Series Product Warranty 8-9 HRX-OM-R039 Chapter

254.2 AW30-03G-A Y300T-A E300-03-A VP744-5DZ1-04-X538 34.4 75.2 118.7 262.7 AW40-04G-A Y400T-A E400-04-A VP744-5DZ1-04-X555 34.4 75.2 160.2 304.2 AW40-04G-A Y400T-A E400-04-A 17 VP500/700-X536, X538, X555 Specific Product Precautions Be sure to read this before handling.

Standard Type Series AN00 How to Order Over 30 dB (A) noise reduction Low back pressure Compact and easy mounting AN 400 04 Port size Thread type Body size 02 03 04 06 10 12 14 20 1/4 3/8 1/2 3/4 1 1 1/4 1 1/2 2 R NPT Nil N 200 300 400 500 600 700 800 900 Specifications Max. operating pressure (1) Fluid Compressed air 1.0 MPa 30 dB (A) Noise reduction Ambient and fluid temperature JIS Symbol

to Order 0 A 04 0 0 M 074 FHG9 Port size Suction guard 04 06 08 10 12 16 20 24 1/2B 3/4B 1B Hydraulic fluid 1 1/4B Air breather 0 1 2 Petroleum Water-glycol, Emulsion Phosphoric ester 1 1/2B Nil Air breather Cap 2B C 2 1/2B 3B Connection Port size category Nominal filtration 0 1 2 3 4 5 Companion flange Female threaded companion flange L-block companion flange L-block female threaded companion

SI unit output no. 0 1 2 3 4 5 6 7 8 9 SI unit output no. 0 1 2 3 4 5 6 7 A B A A B B Unused A Unused A A B A B B A A A VQC Double Double Double Double Double SI Unit SI Unit Single Single Single Single Single SQ Stations 1 2 3 4 5 Stations 1 2 3 4 5 Single/Double Mixed Wiring (Option) Double wiring (Standard) VQ0 Type SC OMRON Corporation SYSBUS Wire System Type SD SHARP Corporation Satellite

VV72-R-03, 04 Individual SUP spacer VV72-P-03, 04 R1, R2 individual EXH spacer VV72-R2-04 Reverse pressure spacer AXT512-19ASilencer box AXT512-26A 1 2 SMC SMC 223.5 211.5 183.5 171.5 140 PA B 80.5 120.5 PE PE PE PA P PE PE P 78 R2 R1 R1 R2 EA EB EB EA A Individual EXH spacer: VV72-R2-Rc3/8, 1/2 Individual SUP spacer: VV72-P2-Rc3/8, 1/2 R1, R2 individual EXH spacer: VV72-R2-04 2-Rc1/2 Reverse

fitting 1(P): Male thread 2(A): One-touch fitting 1(P): One-touch fitting 2(A): Male thread 1(P): Male thread 2(A): Male thread 2(A) 2(A) 2(A) 2(A) Applicable tubing O.D.

, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A EA EB 2-3/8, 1/2 Individual EXH spacer VV72-RA 2-3/8, 1/2 Individual SUP spacer: VV72-P2-1/2 R1, R2 individual EXH spacer: VV72-R2-04 2-3/8, 1/2 Reverse pressure spacer: AX512-19A-1 2 Residual pressure release valve spacer AZ512-59 A B Manual