No malfunction when tested with a drop tester in the axial direction and at a right angle to the armature, one time each in energized and de-energized states. Note 5) Consult P/A regarding drip-proof specifications (equivalent to IP54) .
If there is a risk of contact, provide safety measures such as a cover or a system that uses sensors that will activate an emergency stop before contact is made. 2. Use a balance circuit in which lurching of the piston is taken into consideration.
FGDT/F(L250) Replacement case assembly FGDT/F(L500) FGDC/E(L250) FGDC/E(L500) 25 A FGD Series Dimensions FGDA (1 element) FGDB (2 elements) 108 108 2 x Rc 2 x Rc AIR VENT M6 AIR VENT M6 OUT IN OUT IN B A FGDT FGDF B A DRAIN DRAIN G1/4 G1/4 Element removal dimension: 50 mm (mm) A B Model Element length Port size Rc 314 346 A (L250) FGDC FGDE 574 606 B (L500) 3/8, 1/2, 3/4 314 349 A (L250)
ASR430F-02-08S(-F20) ASR430F-02-10S(-F20) ASR530F-02-06S(-F20) ASR530F-02-08S(-F20) ASR530F-02-10S(-F20) ASR530F-02-12S(-F20) ASR530F-03-06S(-F20) ASR530F-03-08S(-F20) ASR530F-03-10S(-F20) ASR530F-03-12S(-F20) ASR630F-03-10S(-F20) ASR630F-03-12S(-F20) ASR630F-04-10S(-F20) ASR630F-04-12S(-F20) ASQ430F-02-06S(-F20) ASQ430F-02-08S(-F20) ASQ430F-02-10S(-F20) ASQ530F-02-06S(-F20) ASQ530F-02-08S
R mm2 02 02 03 04 04 06 10 10 12 14 20 Port size Rc(PT) 1 11 2 1 4 11 4 1 2 1 8 1 4 1 4 3 8 1 2 1 2 3 4 There were not many appropriate large capacity 5 port valves of a closed center.
Model JIS Symbol 2 position Port size Rc Number of positions Piping direction Model Effective area (mm2) Weight (kg) Series Body mounted Panel mounted (A) 2 (B) 4 VH210-02 VH200-02 3 (Closed center) 4 0.42 VH2 1 (P) 3 (R) VH211-02 VH201-02 3 (Exhaust center) 7.5 1/4 2 VH212-02 VH202-02 2 (Position) 3 1 Closed center VH300-02/03 VH310-02/03 3 (Closed center) (A) 2 (B) 4 4 3 VH301-02/03 VH311
VH30l-02 to 03 2 (A) 4 (B) 25 25 25 4 (B) 1 (P) 3 (R) 1 (P) 62 74 49 62 2 (A) 4-5.5 4-6.6 49 62 125 134 94 97 92 73 106 1 (P) 88.5 23 3 (R) 1 (P) 3 (R) 12 12 27 4-Rc1/4 13.5 4-Rc1/4, 3/8 VH32l-02 to 03 (Bottom piping) 2 (A) 44 3 (R) 1 (P) 4-Rc1/4, 3/8 4 (B) 3.6-9 Hand Valve Series VH Body Mounted/Dimensions VH40l-02 to 04 VH40l-06 4 (B) 2 (A) 4 (B) 2 (A) 25 25 1 (P) 3 (R) SlA 1 (P)
(mm ) 0 2 4 M V VX311 -01 1.5 ZCU 0.29 0 2 4 M V VX312 -01 2.2 1 8 0.60 AMJ 0 2 4 M V VX313 -01 3 0.82 Misc. 0 2 4 M V VX311 -02 1.5 0.29 0 2 4 M V VX312 -02 0.60 M V VX3224 -02 2.2 0.64 M V VX3324 -02 0 2 4 M V 0.82 VX313 -02 1 4 Series VX31 Series VX32 Series VX33 M V 3 VX3234 -02 1.1 M V VX3334 -02 M V 4 VX3244 -02 1.6 M V VX3344 -02 M V VX3224 -03 2.2 0.64 M V VX3324 -03 M V VX3234 -03
P P P Stations are counted from station 1 on the left side, with the A (OUT) ports in front. PA PB PA P PB A A A N.O. PA PB PA A (OUT) port PB A A A Double acting N.C. N.O. Double acting
M a n i f o l d m o u n t e d v e r s i o n s o f t h e V YH y r e g a r e a v a i l a b l e .
A, B port) (Light/surge voltage suppressor) 80 [87] 57.5 [64.5] + 64.6 42.1 36.5 25.5 20 12 43.6 22 22 11.5 34 18 1/4 (R1, R2 port) 31.5 63 L plug connector (L): SYJ7240-L01 02 M plug connector (M): SYJ7240-M01 02 DIN terminal (D): SYJ7240-D01 02 M8 connector (W0): SYJ7240-W001 02 Applicable cable O.D. 3.5 to 7 Approx. 300 (Lead wire length) 91 83.5 57.5 [64.5] 72.2 42.1 M8 x 1 62 57.1 (
When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
Air filter (5m or less) When using a solenoid valve, use a metal seal type (series VQ, VQZ, SQ, etc.).
NARM 2500 05 A 02 G1 Optimal for central pressure control. Accessory Regulator for manifold Pressure easily set using the new handle. One-touch lock system.
Axis A-A' can be aligned to suit.
02 01 02 01 02 DIN terminal (D) VZ54-DVFN Applicable cable O.D.: 3.5 to 7 (Lead wire length) 300 300 (Lead wire length) : With light/surge voltage suppressor 4-6-33 34 Series VZ500 Manifold Specifications Flow Characteristics Flow characteristics Port size 1 2 (P A) 2 3 (A R) C [dm3/(sbar)] C [dm3/(sbar)] b Cv b Cv Manifold 1(P), 3(R) port 2(A) port VV3Z5-20-1 VV3Z5-21-1 VV3Z5-40-2 VV3Z5
A-q A-w A-e A-r A-t A-y A-u A-!1 A-y A-u A-!2 A-!
When air with high purity is required, please either mount the above separator on the outlet side or use a made-to-order product (refer to page 14-19-50), which is provided with a micro mist separator (Series AWD) instead of a regulator. 3.
Thus, in spite of using pneumatic equipment, it performs similarly to a RE A B REC CX CY MQQ M A selection of valve unit is available to suit your application. High cylinder driving speed.