10 10 10 10 10 58 70 87 NN 2 2 2 2 3 4 5 6 7 H 45 45 45 55 35 35 35 38 44 G 15 15 15 15 15 19 37 41 19 N 4 4 4 4 6 6 6 8 8 NA 2 2 2 2 2 2 4 4 4 HA 35 35 35 35 35 70 70 76 88 FF 40 40 40 50 35 60 70 70 80 GA 25 25 25 35 50 54 107 155 195 KA 169 223 275 13-/22-MXS20L-10 13-/22-MXS20L-20 13-/22-MXS20L-30 13-/22-MXS20L-40 13-/22-MXS20L-50 13-/22-MXS20L-75 13-/22-MXS20L-100 13-/22-MXS20L-125
Series 10-/11-/21-/22-CDG1 Series 10-/11-REC Series 10-/11-CDM2X Series Perpendicular entry is unavailable.
Note 1) 5 10 5 10 D-A9 D-A9V D-M9V 5 Note 1) 5 D-M9 10 Note 1) 10 5 Note 2) D-M9W 10 Note 2) 10 5 Note 2) D-M9WV D-M9AV 10 5 Note 2) D-M9A 10 Note 2) 15 15 D-P3DW Note 1) Confirm that it is possible to secure the minimum bending radius of 10 mm of the auto switch lead wire before use.
10 11 10 D-B5/B64 8 9 10 10 11 11 11 10 D-B59W 13 14 14 14 17 16 18 13 D-H7/H7NF/H7W/H7BAL 4 4.5 5 6 6.5 6.5 7 4 D-H7C 7 9 10 9.5 10.5 10.5 11 8.5 D-A3/A44 9 9 10 10 11 11 11 10 D-G39/K39 8 9 9 9 10 10 11 9 4 D-G5/K59/G5W D-K59W/G5BAL/G5NTL Since this is a guideline including hysteresis, not meant to be guaranteed.
48 48 (63) 0 (10) 40 D-M9, D-M9V 10 (17) 0 0 54 59 (66) 48 58 (65) 5 (12) D-F9W, D-F9WV 10 (17) 0 0 54 59 (66) 48 58 (65) 5 (12) ( ): Denotes the values of D-A9V, D-M9V and D-F9WV.
CNG YA-03 YA-05 YA-08 YA-10 18 6.8 16 6 42 6.5 10 YA 03 20 9 20 8 50 6.5 12 MNB Applicable air cylinder bore 26 11 25 10 62 8.5 16 31 14 30 12 76 10.5 18 CNA 03 05 08 10 32, 40 50, 63 80 100 Bore size (mm) 32, 40 50, 63 80 100 Mounting bracket U V W Mass (g) Part no.
10 D-B5/B64 D-B59W 8 9 10 10 13 14 14 13 D-H7/H7W D-H7NF/H7BAL 4 4.5 5 4 D-H7C D-A3/D-A44 D-G39/D-K39 D-G5NTL D-G5NBL 7 9 10 8.5 9 9 10 10 Since this is a guideline including hysteresis, not meant to be guaranteed.
10 D-B5/B64 D-B59W 8 9 10 10 13 14 14 13 D-H7/H7W D-H7NF/H7BAL 4 4.5 5 4 D-H7C D-A3/D-A44 D-G39/D-K39 D-G5NTL D-G5NBL 7 9 10 8.5 9 9 10 10 Since this is a guideline including hysteresis, not meant to be guaranteed.
10 D-B5/B64 D-B59W 8 9 10 10 13 14 14 13 D-H7/H7W D-H7NF/H7BAL 4 4.5 5 4 D-H7C D-A3/D-A44 D-G39/D-K39 D-G5NTL D-G5NBL 7 9 10 8.5 9 9 10 10 Since this is a guideline including hysteresis, not meant to be guaranteed.
Proper Tightening Torque Hexagon socket head bolt diameter (mm) M3 M4 M5 M6 Bore size (mm) Proper tightening torque (Nm) 10 16 20, 25 32 1.08 10% 2.45 10% 5.10 10% 8.04 10% 1251 Series ZCUK Standard Stroke Mounting Stroke (mm) Double acting style/Single rod type/Non-rotating rod Applicable cylinder Stroke (mm) Vertical mounting (Body through-hole) Bore size (mm) 10 16 20 25 32 5 10 15
D-M9W 10 2 pcs. D-M9WV D-M9AV 5 Note 2) 1 pc. 10 2 pcs. 5 Note 2) 1 pc. D-M9A 10 Note 2) 2 pcs. 5 1 pc. D-M9V 5 2 pcs. 5 1 pc. D-A9V 10 2 pcs. 5 1 pc. D-A9 10 2 pcs. 1 pc. 15 D-P3DWA 2 pcs. 15 Note 1) Confirm that it is possible to secure the minimum bending radius of 10 mm of the auto switch lead wire before use.
A A1 E1 L1 MM RR1 U1 ND NX NZ L 34 41 42 56 71 79 8.5 16 25 30 30 40 50 55 M8 x 1.25 10.3 11.5 34 41 42 56 71 79 8.5 10.5 14 18 21 21 16 20 22 28 38 44 25 30 30 40 50 55 M8 x 1.25 10.3 12.8 12 16 21 24 11.5 14 14 20 27 31 8 10 10 14 18 22 8 10 18 22 28 32 8 10 10 14 18 22 8 10 18 22 28 32 IY-G02 IY-G03 IY-G04 IY-G05 IY-G08 IY-G10 20 25 32, 40 50, 63 80 100 I-G02 I-G03 I-G04 I-G05 I-G08 I-G10
Eccentricity 200 mm 1 10 10 0.1 Weight m (kg) Weight m (kg) Weight m (kg) 1 1 20 16 20 16 10 6 20 16 10 6 0.01 0.1 0.1 10 6 0.01 0.001 0.01 80 100 0 20 40 60 80 100 0 20 40 60 80 100 0 20 40 60 Overhang L (mm) Overhang L (mm) Overhang L (mm) Selection Example 1.
Lr=40 mm MXJ4 MXJ4 MXJ4 0.03 0.20 0.10 Table displacement amount (mm) Table displacement amount (mm) Table displacement amount (mm) MXJ4-10 MXJ4-10 MXJ4-5 MXJ4-5 MXJ4-5 MXJ4-5 -10 0.08 -10 0.15 MXJ4-10 MXJ4-10 0.02 0.06 MXJ4-5 MXJ4-5 0.10 0.04 0.01 0.05 0.02 20 40 60 0 10 30 50 20 40 60 0 10 30 50 0 10 5 15 Load (N) Load (N) Load (N) MXJ6 MXJ6 MXJ6 0.04 0.10 0.20 Table displacement amount
Series 10-/11-/21-/22-CDG1 Series 10-/11-REC Series 10-/11-CDM2X Series Perpendicular entry is unavailable.
20 1 MXS 20 16 16 0.1 0.01 MXQ 10 10 6 6 MXF 0.01 0.001 0.1 0 20 40 60 80 100 0 20 40 60 80 100 0 20 40 60 80 100 MXW Overhang L (mm) Overhang L (mm) Overhang L (mm) MXJ Graph (5) Load Eccentricity 100 mm Graph (8) Load Eccentricity 100 mm Graph (11) Load Eccentricity 100 mm MXP 1 10 10 MXY Mass m (kg) 0.1 MTS 1 Mass m (kg) Mass m (kg) 20 16 10 6 1 20 20 16 10 16 0.01 0.1 10 6 6 0.001 0.1
Selection Graph [Graph 2] Allowable load mass by stroke 10 [Graph 1] Allowable load mass by stroke 6 10 10 Load mass [kg] Load mass [kg] y, z + A 200 y, z + A 300 y, z + A 100 1 1 0 100 200 300 400 500 600 0 100 200 300 400 Stroke [mm] Stroke [mm] [Graph 4] Allowable load mass by stroke 20 [Graph 3] Allowable load mass by stroke 15 100 10 y, z + A = 0 Load mass [kg] Load mass [kg] y, z
MXP 6-5 MXPJ6-5 MXP 6-10 MXPJ6-10 0.05 0.05 0.06 0.04 Table displacement mm Table displacement mm Table displacement mm 0.04 0.03 0.04 0.03 0.02 0.03 0.02 0.02 0.01 0.01 0.01 0 10 20 30 40 Load N 0 10 20 30 50 Load N 0 10 20 30 40 Load N 40 10 10 10 L = 100mm L = 100mm L = 100mm MXP10-10 MXP10-20 MXP10-10 MXP10-20 0.04 0.03 0.08 MXP10-10 MXP10-20 MXP10-10 MXP10-20 MXP10-10 MXP10-20 MXP10
JM-045 JM-10 JM-10 JM-045 JM-045 *Components include in a seal kit.
10 10 2 pcs. 10 15 20 2 pcs. 5 10 15 15 20 20 15 32, 40, 50 32, 40, 50 5 15 10 5 1 pc. 10 10 20 1 pc. 5 5 10 15 15 20 15 Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted.