(External Pilot), Back Pressure Check Valve: None, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: U (w/Light/Surge Voltage Suppressor, Non-polar), Manual Override: F (Slide Locking Type), A,B Port Size: Base Mounted Valve, Thread: Rc (or No Selection in the Case of M5 or One-touch Fittings), Mounting Option: K
None, Pilot Valve: Standard (0.7MPa), Coil Specification: T (w/Power Saving Circuit, Continuous Duty Type), Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: Z (w/Light/Surge Voltage Suppressor, Positive Common), Manual Override: Non-locking Push Type, A,B Port Size: Base Mounted Valve, Thread: Rc (or No Selection in the Case of M5 or One-touch Fittings), Mounting Option: K
None, Pilot Valve: Standard (0.7MPa), Coil Specification: T (w/Power Saving Circuit, Continuous Duty Type), Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: Z (w/Light/Surge Voltage Suppressor, Positive Common), Manual Override: F (Slide Locking Type), A,B Port Size: Base Mounted Valve, Thread: Rc (or No Selection in the Case of M5 or One-touch Fittings), Mounting Option: K
None, Pilot Valve: Standard (0.7MPa), Coil Specification: T (w/Power Saving Circuit, Continuous Duty Type), Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: Z (w/Light/Surge Voltage Suppressor, Positive Common), Manual Override: Non-locking Push Type, A,B Port Size: Base Mounted Valve, Thread: Rc (or No Selection in the Case of M5 or One-touch Fittings), Mounting Option: K
Body Class: 2 (ø4 Orifice), Valve Type: 0 (N.C.), Fitting Type: V (LQ1, Body Class: 2, 3, 4, 5, 6), Tube Size: 03 (1/8" or ø3), Output Tube Size: None, Pilot Connection: N (Thread Type 1/8"NPT), Pilot Port Direction: Direction 1, Option 1: 5 (High Back Pressure, 0.42 MPa), Option 2: K (Buffer Material FFKM)
Body Class: 2 (ø4 Orifice), Valve Type: 0 (N.C.), Fitting Type: V (LQ1, Body Class: 2, 3, 4, 5, 6), Tube Size: 07 (1/4"), Output Tube Size: None, Pilot Connection: N (Thread Type 1/8"NPT), Pilot Port Direction: Direction 1, Option 1: 5 (High Back Pressure, 0.42 MPa), Option 2: K (Buffer Material FFKM)
Body Class: 3 (ø8 Orifice), Valve Type: 0 (N.C.), Fitting Type: V (LQ1, Body Class: 2, 3, 4, 5, 6), Tube Size: 07 (1/4"), Output Tube Size: None, Pilot Connection: N (Thread Type 1/8"NPT), Pilot Port Direction: Direction 1, Option 1: 5 (High Back Pressure, 0.42 MPa), Option 2: K (Buffer Material FFKM)
Cooling Capacity: 100, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: K (w/Fluid Fill Port)
Cooling Capacity: 150, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: K (w/Fluid Fill Port)
Cooling Capacity: 200, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: K (w/Fluid Fill Port)
Cooling Capacity: 150, Thread Type: Rc, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: K (w/Fluid Fill Port)
Cooling Capacity: 150, Thread Type: F [G (w/Rc-G Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: K (w/Fluid Fill Port)
Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: K (w/Fluid Fill Port, Manual)
Cooling Capacity: 100 (10 kW), Cooling Method: W (Water-cooled), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: K (w/Fluid Fill Port, Manual)
Cooling Capacity: 100 (10 kW), Cooling Method: W (Water-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: K (w/Fluid Fill Port, Manual)
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: K (w/Fluid Fill Port, Manual)
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: K (w/Fluid Fill Port, Manual)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: K (w/Fluid Fill Port, Manual)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: K (w/Fluid Fill Port, Manual)
Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: K (w/Fluid Fill Port, Manual)