(Default setting) 8 7 Configuration Mode Address X1 9 6 x10 x1 2 1 0 0 5 Mark C on the unit Mark B at cable end Mark A at cable end 4 Address 1 9 4 3 1 0 : : (1) 2 3 Input data + System diagnosis + Unit diagnosis (Up to 10 units) Input data + System diagnosis Input data only (Default setting) 8 7 9 6 6 Content 3 4 1 2 0 5 Content 5 0 (Default setting) 4 1 2 3 Node Address Data Rate 8 7 PGM
10 10 14 14 15 17 17 21 21 51 58 58 71 72 8 11 11 13 16 M8 x 1.25 M8 x 1.25 M10 x 1.25 M12 x 1.75 M12 x 1.75 6 7 7 10 10 14 18 18 22 26 11 11 14 17 17 M14 x 1.5 M18 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 27 30 31 37 40 1/4 3/8 3/8 1/2 1/2 84 90 98 116 126 146 159 170 204 215 16
AR30 Option Thread type Port size Symbol Nil B E G P Applicable models AR30 to 60 AR30 to 60 AR30 to 60 AR30 to 40 Contents With bracket With square embedded type pressure gauge (with limit indicator) Round pressure gauge (with limit indicator) Panel mount (with set nut) Metric thread (M5) Rc NPT G Nil Note 1) 1 4 02 03 04 06 10 N F 3 8 Note 2) 1 2 3 4 1 Note 1) Bracket assembly is not
Lock keys (refer to P9) Minimum pressure (F_1) adjusting range Maximum pressure (F_2) adjusting range 120% 100% 100% 90% 10% 0% 0% 4 0 0 0 12 10 20mA 20mA 4 0 0 0 12 10 20mA 20mA 2.5 5V 2.5 5V 5 10V 5 10V (Note1) F_1 is adjustable in a range from 0% to 90% of the rated value. (Default value : 0%0.00MPa) (Note2) F_2 is adjustable in a range from 10 to 120% of the rated value.
With Connector/How to Order ZS-10-A Without lead wire (Connector 1 pc. Socket 3 pcs.) ZS-10-5AWith lead wire Lead wire length Nil Note) When ordering switch with 5 m long lead wire, Indicate both part numbers. Ex.) ZSP1-0X-15CN 1 pc.
How to Order AS 2 2 0 1F G 01 06 W2D Flame resistant flat head screwdriver adjustable Body size 2 1/8, 1/4 standard 3 3/8 standard 4 1/2 standard Applicable tubing O.D.*1 Metric size 06 6 08 8 10 10 12 12 Elbow Control method 0 Meter-out 1 Meter-in *1 For selecting applicable tubing O.D., refer to the Model shown above.
Function Function Terminal name Terminal name 24 V 1 1 COM+ COM+ 24 V 0 V 2 2 COM COM 0 V Pulse signal 3 3 NP+ NP+ Pulse signal Pulse signal 4 4 NP NP Pulse signal Note 1) Note 1) Pulse signal 5 5 PP+ PP+ Pulse signal Pulse signal 6 6 PP PP Pulse signal Input 7 7 SETUP SETUP Input Input 8 8 RESET RESET Input Input 9 9 SVON SVON Input Input 10 10 CLR CLR Input 11 11 12 12 Load Load 13 Output
Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo C.P. 36100, Silao, Gto., Mexico TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46 FRANCE SMC Pneumatique S.A. 1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600 Marne La Vallee Cedex 3 France TEL: 01-64-76-10-00 FAX: 01-64-76-10-10 CHILE SMC Pneumatics (Chile) S.A. Av. La Montaa 1,115 km. 16,5 P.
10 10 12 12 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" -X214 Restrictor (Without check valve) With One-touch ttings Example) AS2002FS-04-X214 With indicator 10Clean Series 1 For selecting applicable tubing O.D., refer to the Model shown above. 2 Use 1/8" tubing.
Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo C.P. 36100, Silao, Gto., Mexico TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46 FRANCE SMC Pneumatique S.A. 1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600 Marne La Vallee Cedex 3 France TEL: 01-64-76-10-00 FAX: 01-64-76-10-10 CHILE SMC Pneumatics (Chile) S.A. Av. La Montaa 1,115 km. 16,5 P.
With Connector/How to Order ZS-10-A Without lead wire (Connector 1 pc. Socket 3 pcs.) ZS-10-5AWith lead wire Lead wire length Nil Note) When ordering switch with 5 m long lead wire, Indicate both part numbers. Ex.) ZSP1-0X-15CN 1 pc.
Pitch (Section F-F') Port size (The above diagram is for ZFA200) ZFA100 Port size Symbol Model A B 19 18 24 28 1 8 1 4 ZFA200 L1 1 Number of manifold stations Model Symbol 2 56 68 76 88 3 74 86 104 116 4 92 104 132 144 5 110 122 160 172 6 128 140 188 200 7 148 158 216 228 8 164 176 244 256 9 182 194 272 284 10 200 212 300 312 38 50 48 60 ZFA100 L2 L1 L2 ZFA200 13-10-3
Individual, Common Not required (Use turbine oil #1(lSO VG32) if lubrication is Free 30Gy'5G (8.5 -2000H2) Dust proot Solenoid S ifications Grommet (G) (H), Plug connector (L) (M), DIN connector (D) 1 1 OV 5 a/6aqz, 220V. a I oqz 24V 5a,1a Hz 12V,24V 15+10% of rated voltage utass E ot equrvatenl (z5u r l 81'F or less 1.8W,,,2.1W (W/LED) 4.zVA/6OHz 4.5vA/soHz 3VA/60H2 3.5VA/50H2 DC : Diode
Vacuum to 250 psig (1.7 MPa) Vacuum to 125 psig (0.9 MPa) 1000 psig (6.9 MPa) 8000 psig (55.2 MPa) 14 to 160F (10 to 71C) (No freezing) 1) 0.29 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 2) 4 x 10-9 Pam3/sec 2) Ra max 15 in. (0.4 m) Option: 10 in. (0.25 m), 7 in. (0.18 m), 5 in. (0.13 m) Face seal, Tube weld 70 to 110 psig (0.48 to 0.76 MPa) 10-32 UNF thread Side Bottom mount 0.06 in3 (1.07 cm3
34 55 107 1 8 1 4 3 8 1 2 Specifications 1.5 MPa 0 to 1 MPa 5 to 60C (No freezing) 10 turns (8 turns Note)) Proof pressure Operating pressure range Ambient and fluid temperature Number of needle rotations AS ASP Note) ( ) is the case of ASN2-M5 and ASN2-U10/32.
to 71C) (No freezing) 1) 0.3 1 x 10-10 Pam3/sec NPT female, Compression Bottom mount (Option: panel mount) 0.49 in3 (8 cm3) 2.65 lbs (1.2 kg) 2) 1) 22 to 160F (30 to 71C) for Teflon seat.
Types S, Z 24 VDC: 7 to +10 %, 12 VDC: 4 to +10 % Type T 24 VDC: 8 to +10 %, 12 VDC: 6 to +10 % Note 1) Impact resistance: Made to Order Specifications (For details, refer to pages 1847.) Symbol Specifications No malfunction resulted from the impact test using a drop impact tester.
Hysteresis mode 2 Panel Item Default settings Model button (UP) Panel mount adapter Item Default setting ( ) PF2A30 series [10L] 1 to 10 L/min type (PF2A510) Indicator LED (OUT1) Set point 1 Set point 2 Hysteresis 1 Hysteresis 1 50% of max. rated flow [n_1] Input of the Set point 1 (OUT1) PF2A31 series [11L] 10 to 100 L/min type (PF2A511) button (SET) ON 50% of max. rated flow [n_2] Input
Intrinsically Safe Valve 5 Port Solenoid Valve Series 53-SY5000/7000/9000 Body Ported Electrical Entry L and LL Hazardous Location Class I Division 1 Groups A, B, C, D Electrical Entry TT Hazardous Location Class I, II, III Division 1 Groups A, B, C, D, E, F, G Single Unit Warning Do not install in Zone 0 (as defined in IEC 60079-10-1: 2008) or Zone 20 (as defined in IEC 60079-10-2: 2009)