SMC Corporation of America
Elite Part Number Search
Search Results "PF3A712H-N20-L3"

) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rc, NPT, G 1/8 24 36 36 n Stations 1 Left Right 1 46 2 84 38 3 122 38 76 4 160 76 114 5 198 114 152 6 236 152 190 Stations L1 L2 L3 63(Max. 65) 34 5 17 Detection port 19 For the bracket attachment position, refer to page 16-8-16.

.\ L3 2.83 (72\ 3.46 (88) 4.09 (104) 4.72 (120\ 5.35 (136) 5.98 (152) 6.61 (168) 7.24 (18/.\ 7.87 (2001 Millimtef in parentheses, 53 C Single-Stage Nozzle (o1.5) . Produces high suction flow with quick response time. . Interchangeable with all other nozzleldiffuser ass'ys.

L3 2.83 (72\ 3.46 (88) 4.09 (104) 4.72 (120\ 5.35 (136) 5.98 (152) 6.61 (168) 7.24 (18/.\ 7.87 (2001 Millimtef in parentheses 53 C Single-Stage Nozzle (o1.5) . Produces high suction flow with quick response time. . Interchangeable with all other nozzleldiffuser ass'ys.

L3 L4 L5 VF1000 VF3000 VF5000 34.5 60 95 4.2 4.2 3.45 33.4 59 89 5EA 1P L2 29.5 44.5 45.5 63.5 L5 L4 TRIAC Output Specification 2 For AC type valve, use this specification when the pilot valve is not recovered even though valve power supply is turned OFF at the equipment using output unit with large leakage voltage over 8% of the rated voltage (TRIAC output such as PLC or SSR, etc.).

IDF60,70,80,90-20 IDF60,70,80,90-30 Rubber grommet Signal cable entry (Single phase AC200V) (Three phase AC200V) Strain relief Power supply cable entry L N PE L1 L2 L3 PE (to be connected to the user's equipment) Refer to 3-5 for details for electric wiring.

(Tightening torque: 1.0 Nm) Terminal width 9.9mm PE L3 L2 L1 24 23 6 5 22 21 Remote operation Error signal Ground RUN signal Power supply (to be connected to the user's equipment) IDF190D/240D Series 3.2Installation 3-5 IDX-OM-Y002 Chapter 3 Transportation and installation 4) Mount the front panel back. [Remote control] Voltage of AC200V is present on the terminal block.

HRLE050 200V N L HRLE090 200V L3 L1 L2 Fig. 3-12 Cable wiring (200V) 3.3 Installation Procedure HRLE Series 3-16 HRX-OM-Z002 Chapter 3 Transport and Set Up 400V L1 L2 L3 Fig. 3-13 Cable wiring (400V) HRLE Series 3.3Installation Procedure 3-17 HRX-OM-Z002 Chapter 3 Transport and Set Up 3.3.4 Preparation and wiring of communication cable Be sure to turn OFF the breaker of the facility power

Power supply voltage is 200VAC single phase Trouble OFF ON RA MC Emergency stop MC SK (Note 6) Driver Servo motor Servo amplifier (Note 7) Controller CNP1 MC NFB 1-phase 200 to 230VAC L1 CNP3 (Note 5) U L2 U Motor V L3 V [1] M W N W P1 (Note 1) P2 PE CNP2 P [2] (Note 2) C [3] D Encoder CN2 (Note 3) Encoder cable L11 L21 [1] Provide specified power supply to input terminals L1 and L2. [2]

1000mm 0 0 0 1 2 3 4 5 0 1 2 3 4 5 Horizontal Mounting Workload[kg] WorKload[kg] 600mm 500 500 Overhang direction:L2[mm] Overhang direction:L2[mm] 500mm or less 400 400 300 300 900mm stroke or less 700mm m 200 200 L2 800mm 1000mm stroke 100 100 900mm 1000mm 0 0 0 1 2 3 4 5 0 1 2 3 4 5 Workload[kg] Workload[kg] 300 300 Overhang direction:L3[mm] Overhang direction:L3[mm] 250 250 600mm stroke L3

Auto Switch Made to Order 62 C75 Series Dimensions of Accessories Rod End dH7 45 d3 b1 b3 l l3 d7 d6 h [mm] Bore size Part no. b1 b3 dH7 d6 d7 h l l3 d3 a 32 KJ10DA 14 10.5 10 28 19 43 20 15 M10 x 1.5 13 40 KJ12DA 16 12 12 32 22 50 22 17 M12 x 1.75 13 Floating Joint: JA M M U U D F G H B P E A [mm] Bore size Part no.

Separate cable IZT40-CF Shield wire Semi-stripped terminal Cable length L3 Cable specification Product No. L3(mm) Number of wire /size 12 cables/AWG20(4pcs. ), AWG(8pcs.) Nominal cross section 0.54mm2(4pcs.), 0.09mm2(8 pcs.) 0.96mm (4pcs. ), 0.38mm (8pcs. ) IZT40-CP3 2950 Conductor O.D.

Bottom mounting (Body tapped) L2 L3 Size Pin Effective depth [mm] Screw Max. screw-in [mm] depth [mm] 10 3 3.5 M8 x 1.25 12 20 4 4.5 M10 x 1.5 15 30 4 4.5 M10 x 1.5 15 50 5 5.5 M12 x 1.75 18 3.

Power supply is AC200V single phase (Note 4) Controller Forced Alarm forced stop stop ON OFF RA1 RA2 MC MC SK Driver Servo amplifier Servo motor NFB MC CNP1 L1 1-phase 200 to 230VAC CNP3 (Note 6) U 2 L2 U Motor [1] V 3 L3 V M N W 4 W 1 P1 (Note 1) P2 PE CNP2 P (Note 2) C [3] [2] D (Note 3) Encoder CN2 Encoder cable L11 L21 CN3 CN3 24VDC Forced stop EM1 DOCOM (Note 5) DOCOM DICOM (Note 5)

4 One-touch fitting for 6 One-touch fitting for 5/32" One-touch fitting for 1/4" M5 01 C4 C6 N3 N7 Nil Rc G NPT NPTF F N T Clean series A port M5 x 0.8, 1/8, C4, C6 Note) For more than 9 stations, supply air to both sides of P port and exhaust air from both sides of R port. 679 Manifold specifications 10-SYJ500 Type 20 manifold: Top ported / 10-SS3YJ5-20Stations -00(-F) [ ]: AC (18.5) L3

Body A 1 Brass Electroless nickel plated Body B 2 Brass Electroless nickel plated Valve 3 Aluminum O-ring 4 HNBR Spring 5 Stainless steel Pad side Element 6 BC ZP2V-AZP2V-BGasket 7 NBR + Stainless steel 63 Series ZP2V Vacuum Saving Valve Dimensions Vacuum generator side Vacuum generator side M2 M2 H1 H1 Vacuum generator side L2 L1 L3 L2 M2 H1 L2 L33 (L4) (L4) No.0.8 No.0.8 L1 L3 L2 L3

Connect the stripped cable to the L, N, PE terminals(For 400V, L1, L2, L3, PE) of the female connector. (Recommended tightening torque: 0.7 Nm) Female connector Screw (Recommended thightening torque : 0.7Nm) PE 2(N) 1(L1) 1(L) 2(L2) PE 3(L3) 200V type 400V type Fig 3-5 Cable connection HRR Series 3.3 Installation 3-11 HRX-OM-X071 Chapter 3 Transport and Setting Up 5.

Load weight (kg) Caution The cylinder should be mounted in m1 orientation if maximum dustproofing is required. m m m Moment (Nm) M = F x L F3 M = F x L M = F x L F F2 L2 L1 L3 Maximum load weight Select the load weight from within the range of limits shown in the graphs. Note that the maximum allowable moment value may sometimes exceed even the operating limits shown in the graphs.

L3 lK lJ lH Reset button View port lK 4 x P Mounting hole Mounting base dimensions A A L Differential pressure indication switch Operating pressure0.18 MPa When a value has been displayed, it will be automatically reset when the pump is stopped. (Non-reset type) This is a visual dual-purpose 2-stage display.

Body A 1 Brass Electroless nickel plated Body B 2 Brass Electroless nickel plated Valve 3 Aluminum O-ring 4 HNBR Spring 5 Stainless steel Pad side Element 6 BC ZP2V-AZP2V-BGasket 7 NBR + Stainless steel 63 Series ZP2V Vacuum Saving Valve Dimensions Vacuum generator side Vacuum generator side M2 M2 H1 H1 Vacuum generator side L2 L1 L3 L2 M2 H1 L2 L33 (L4) (L4) No.0.8 No.0.8 L1 L3 L2 L3

Load (kg) m1 m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2 1. Maximum allowable load (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. Maximum Allowable Load To evaluate, use a (average speed) for (1) and (2), and (impact speed = 1.4a) for (3).