Heater operation, PID control Refrigerant type/Refrigerant charge R134a/0.14kg R134a/0.26kg Niose level (reference value) Note 7) 52dB (A) 55dB (A) Weight 26kg 37kg Applicable drain tube O.D. 10mm Coating colour Body panels:White 1 Base:Gray 2 IP Class IP2X Overvoltage Category Category / IEC60664-1 Pollution Degree Degree 2 Applicable directive CE Marking Note 1: ANR refers to conditions of 20C
Standard condition (ANR) and normal condition (NOR) are defined as follows: Standard condition (ANR): 101.3kPa, 20C, 65%RH. Normal condition (NOR): 101.3kPa, 0C
Long life is achieved by a new pilot design, guide rings that prevent main valve eccentricity, and a stronger return force. 1.2-4 New New 5 port solenoid valve series SY9000 Nl/min 2748.2 (base mounted type with sub-plate) Interface regulator series ARBY3000/5000 (for series SY3000/5000/7000) SV SY SY High speed response: 10ms SYJ (SY3000 single solenoid, 0.5MPa, 20C) (representative value
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) For details, please contact SMC.
TL TIL TLM TILM TD TID TH TIH 913 LQ3 Series Specifications Model Feature LQ310 LQ320 LQ330 LQ340 LQ350 LQ360 LQ370 Material New PFA Maximum operating pressure (at 20C) 1.0 MPa Refer to the withstand pressure and heat resistance performance data.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) Note 2) Impact resistance: No malfunction occurred when it was tested in the axial direction and at right angles to the main valve and armature in both energized and de-energized states once for each condition.
Inch size 1/4" 1/8" 5/32" Flow rate (l/min(ANR)) 170 100 120 150 IN OUT Effective area (mm2) 2.6 1.5 1.8 2.3 IN P1 Note) Flow rate is the value measured under a pressure of 0.5 MPa and a temperature of 20C.
S7, S8: Absolute 18-bit encoder (Resolution: 262144 p/rev) 25APower consumption [W] Note 7) Horizontal 45 65 210 Vertical 145 175 230 LEC Standby power consumption when operating [W] Note 8) Horizontal 2 2 2 Vertical 8 8 18 LEC S Max. instantaneous power consumption [W] Note 9) 445 725 1275 Type Note 10) Non-magnetizing lock Holding force [N] 131 255 197 385 330 660 Power consumption at 20C
Standard condition and normal condition are defined as follows: Standard condition: Displayed flow rate which is converted to volume at 20C, 101.3 kPa (absolute pressure). Normal condition: Displayed flow rate which is converted to volume at 0C, 101.3 kPa (absolute pressure).
Rod Boot Material 125 140 160 180 200 250 Max. ambient temperature Symbol Material Bore size (mm) J 20C Foot type Note 1) Nylon tarpaulin CS1-L12 CS1-L14 CS1-L16 CS1-L18 CS1-L20 CS1-L25 110C K Rod flange type Note 2) Heat resistant tarpaulin CS1-FL12 CS1-FL14 CS1-FL16 CS1-FL18 CS1-FL20 CS1-FL25 Head flange type Maximum ambient temperature for the rod boot itself.
EX510 Conductor resistance W/km, 20C 65 or less COM. COM. Manifold Exploded View 13 (+) 13 () Voltage limit V, 1 minute, AC 1000 common Negative common Positive Fitting, Plug Part Nos. Insulation resistance MW/km, 20C 5 or more * When using a valve with no polarity, either positive common or negative common can be used.
Features 1 New New 5 port solenoid valve series SY9000 Cv 2.8 (base mounted type with sub-plate) Interface regulator series ARBY3000/5000 (for series SY3000/5000) High speed response: 10ms (SY3000 single solenoid, 0.5MPa, 20C) (representative value) The innovative design of the pilot valve makes it possible to achieve a short response time of 10ms while consuming only a half watt of power
Residence time of water at 20C is 5.5 x 10-6 sec, whereas at 150C, it is 2.8 x 10-8 sec, or about 200 times shorter. The objective of baking is to exhaust water with long adsorption residence time more quickly. XVD Surface leakage This leakage occurs between surfaces of the sealing and the seal material.
Symbol Proportional Solenoid Specifications Max. current 1A VEA250,VEA251 Applicable power amplifier 13W(20C, With maximum current) 13(20C) Coil resistance Rated power consumption Class H or equivalent (180C) Coil insulation 140C(With maximum current) Max. temperature rise DIN terminal Electrical entry Manifold Accessory Mounting screw (With washer) M5 X 45 VER2000 VER4000 Model AXT500-13
Elbow Type (Metal body) Air Flow/Effective Area AS220M-02 AS120M AS220M-01 Model R 1/4 Cylinder side M5 x 0.8 10-32 UNF NPT 1/8 NPT 1/4 R 1/8 Port size Rc 1/4 Tube side Rc 1/8 Air flow (L/min (ANR)) 38 7 12 REA Controlled flow Effective area (mm2) 0.6 0.1 0.2 Flow rate (L/min (ANR)) 420 105 280 REB Free flow Effective area (mm2) 6.5 1.6 4.3 Note) Supply pressure: 0.5 MPa, Temperature: 20C
Note 2) The above data is based on a room temperature of 20C. Note that you may obtain different figures, depending on temperature conditions. Note 3) The above data shows compatibility guidelines based upon component parts. Therefore, it is no guarantee of product performance. In addition, using fluids other than those specified in the catalog are not covered by the products warranty.
slotted style Max. operating frequency (Hz) VP Manual override Individual pilot exhaust style, Common Exhaust (pilot and main valve) style Pilot exhaust Not required Lubrication Base mounted Free Mounting position VQ Impact/Vibration resistance (m/s2) (2) 150/30 JIS Symbol Dust proof Protection structure VQZ Note 1) According to dynamic performance test JIS B8374-1981 (Coil temperature 20C
How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 + 0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min (ANR)] S: Effective area (mm) P: Differential pressure (P1-P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures
145PSI 14: 30 38: 40 Min Operating Flow ln/min* 4 15 12: 50 190 220 38: 40 (N)AL Bowl Capacity cm3 7 25 50 130 130 130 Recommended Oil ISO VG32 Ambient and Media Temperature 5 ~ 60C / 40~140F O P T I O N A L S P E C S Japanese N North American Bowl Material Polycarbonate Accessory (Standard) Bowl Guard B O D Y S I Z E *Conditions: Supply pressure 0.5MPa Number of DROPS 5 drops/min ISOVG32, 20C
M km, 20C 5m VVZS3000-21A-3 x 24AWG * For other commercial connectors, use a 25-pole female connector made in conformity with MIL-C-24308.