Insulation resistance Mkm, 20C 5 or less 16 44 8 Connector manufacturers example Fujitsu, Ltd. Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Calcium hydroxide 8 RHC Magnesium hydroxide 9 Acetylene 10 MK(2) Formic acid (25%, Room temperature) 11 Organic solvent 12 Citric acid RS Q G 13 Acetic acid (10%, Room temperature) RS H A Lactic acid (5%, 20C) 14 15 Linseed oil RZQ 16 Polassium

Local Area: (800) 258-9200-www.stevenengineering.com Maximum response frequency 500Hz Indicator light Red LED (lights up when ON) Ambient temperature 10 to 55C Environmental resistance Ambient humidity 45 to 85% RH Power line: 240Vp, pulse width of 0.5s Noise resistance Temperature characteristics Voltage characteristics Detecting distance fluctuation Within +15/10% of detecting distance at 20C

(Coil temperature: 20C, at rated voltage) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Compact design with large flow Sonic conductance: C [dm3/(sbar)] Body width [mm] 10 15 18 1.1 2.8 4.5 Response time 10 ms (Representative value) (SX3000 double, 0.5 MPa, 20C) High reliability and long service life exceeding 50 million cycles or more (

COM COM Conductor resistance /km, 20C 65 or less Note) Mounting valve has no polarity. It can also be used as a negative common. Voltage limit V , 1 min, AC 1000 SpecialWiring Specifications (Option) [-K] Insulation resistance M/km, 20C 5 or more Mixed single and double wiring are available as an option. The maximum number of manifold stations is determined by the number of solenoids.

65 or less Gray 23 Red 1000 Withstand voltage VAC, 1 minute Black 24 White Insulation resistance Mkm, 20C 5 or less White 25 None Note) The minimum bending radius of each cable is 20 mm.

DStroke range: 51 to 599 mm MY2 X168 Bore size Stroke Auto switch Symbol Bore size Stroke Auto switch Symbol MY2 XB10 -X Series/Bore size 16 25 40 20C H HT Cam follower guide type High precision guide type (Single axis) High precision guide type (Double axis) Series/Bore size 16 25 40 H HT High precision guide type (Single axis) High precision guide type (Double axis) Data (Example) MY2H40G

thermal insulation to the piping at air outlet and keep the piping length as short as possible in order to prevent condensation on the outlet piping and temperature increase on the outlet due to ambient temperature. 7.4 Air flow capacity Model IDF15E1-10/20-A Air flow capacity m3/min(ANR) Note1) 50Hz 1.2 60Hz 1.3 Outlet air temp. oC 10 Note1) The data for ANR is referring to the conditions of 20C

Note 2: ANR indicates the following set of conditions: a temperature of 20C, atmospheric pressure, and a relative humidity of 65%. Note 3: Air flow capacity converted by the compressor intake condition [32C, atmospheric pressure, and 75% relative humidity]. Note 4: Do not use this product with continuous voltage fluctuations.

Note 2: ANR indicates the following set of conditions: a temperature of 68 oF (20C), atmospheric pressure, and a relative humidity of 65%. Note 3: Allowable voltage fluctuation +/-10%. Do not use this product with continuous voltage fluctuations.

Standard condition: Flow rate converted to a volume at 20C and 101.3 kPa (absolute pressure) Normal condition: Flow rate converted to a volume at 0C and 101.3 kPa (absolute pressure) Response time The response time can be selected to suit the application.

Standard condition (ANR) and normal condition (NOR) are defined as follows: Standard condition (ANR): 101.3kPa, 20C, 65%RH. Normal condition (NOR): 101.3kPa, 0C Press the or button in function selection mode to display [F 4]. Press the button.

Note AXT100-DS25-015 AXT100-DS25-030 AXT100-DS25-050 1.5 m 3 m 5 m Conductor resistance /km, 20C 65 or less Cable 25 cores x 24AWG Withstand pressure V, 1 min, AC 1000 For other commercial connectors, use a 25 pins type with female connector conforming to MIL-C-24308. Insulation resistance Mkm, 20C 5 or less Note) The minimum bending radius for D-sub connector cables is 20 mm.

. * Cannot be used for movable wiring Electrical Characteristics Connector manufacturers example Item Property Conductor resistance W/km, 20C 65 or less Fujitsu Limited Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. HIROSE ELECTRIC CO., LTD.

Note 2: ANR indicates the following set of conditions: a temperature of 20C, atmospheric pressure, and a relative humidity of 65%. Note 3: Air flow capacity converted by the compressor intake condition [32C, Atmospheric pressure, and 75% relative humidity] Note 4: Do not use this product with continuous voltage fluctuations.

cooling Corrugated fin tube type with forced air cooling Refrigerant R407C(HFC) Refrigerant Charge Quantity 42010g 73010g 55010g 67010g Air IN/OUT Connection R1 R1-1/2 R2 Drain Connection (Outside Diameter of Tubing) 10mm Painting Finish Melamine baking finish Colour Munsell 10Y8/0.5 (Urbanwhite) Weight 54kg 62kg 100kg 116kg Note1: The data for m3/h (ANR) is referring to the conditions of 20C

(53010g) (73010g) (43010g) (59010g) Thread Symbol N (male) NPT1 NPT1-1/2 NPT2 Thread Type Thread Symbol None (male) R1 R1-1/2 R2 and Size Drain Tube Thread Symbol N 3/8inch Thread Symbol None 10mm Painting Finish baking finish Colour Panel : Urbanwhite1 Weight 119lbs 137lbs 258lbs 271lbs (54kg) (62kg) (117kg) (123kg) Note1: The data for SCFM (ANR) is referring to the conditions of 68F (20C

Standard condition: Flow rate converted to a volume at 20C, 101.3 kPa (absolute pressure), and 65% RH Normal condition: Flow rate converted to a volume at 0C, 101.3 kPa (absolute pressure), and 0% RH Reversible display mode When the switch is used upside down, the orientation of the display can be rotated to make it easier to read by using the reversible display function.

Heater operation, PID control Refrigerant type/Refrigerant charge R134a/0.14kg R134a/0.26kg Niose level (reference value) Note 7) 52dB (A) 55dB (A) Weight 26kg 37kg Applicable drain tube O.D. 10mm Coating colour Body panels:White 1 Base:Gray 2 IP Class IP2X Overvoltage Category Category / IEC60664-1 Pollution Degree Degree 2 Applicable directive CE Marking Note 1: ANR refers to conditions of 20C