Model Bolt Max.tightening Torgue (Nm) JMHZ2-16D M3 x 0.5 0.59 Attachment 15 How to Mount Air Gripper Adjust the robot arm position before mounting so that the mounting is easy. (1) Mounting to the robot arm (2) Mounting of the cover Take care not to get the switch cable Caught when mounting the cover.
Model Bolt Max.tightening Torgue (Nm) JMHZ2-16D M3 x 0.5 0.59 Attachment 14 How to Mount Air Gripper Connector storage Set the three connectors at the end of the robot hand according to the characters printed on the flange. The connection part of the connectors are set in the direction of the arrows.
JMHZ2-16D-X7400B-HC10-(*) P13P14P15 4 M6 31.5 2XM4x0.7 8 4 M6 108.8L 4 4 M4 4 M3 27 17 10 - JMHZ2-16D-X7400B-HC10DT-(*) 4 M6 32.5 8 4 M6 109.8L 4 4 M4 4 M3 27 17 11 - 3-6. M8 8 M8-Molex P .19 NPN PNP No. 1 +24V DC24V 2 GND DC0V 3 ON/OFF() 4 ON/OFF() 5 () 6 () 7 8 Molex (51227-0800) M8 8 12 - 3-7.
Loosen the hexagon socket head cap screws (M3 x 30:2 locations) which are fixing the SI unit. 2. Separate the SI unit to valve manifold. 3. Add and increase the attached tie-rod (2 pcs. per block) to the increased block respectively and pass through a block by the tie-rod. 4.
Caution (1)For M3, M5, 10-32UNF Tightening method (10)Do not apply excessive force or shock to For M3 First, tighten it by hand, then give it an additional 1/6 turn to 1/4 turn with a hexagon wrench. Refer to Table below for reference. the body or fittings with an impact tool.
The terminal screw is an M3 round head combination screw. Terminal Connection BS+ Connect the communication power supply BS+. BDH Connect the communication cable BDH. BDL Connect the communication cable BDL. BSConnect the communication power supply BS-.
B RATE Terminal board Terminal Connected to MS+ BS+ of communication power line BDH BDH of communication line BDL BDL of communication line BSBSof communication power line FG Ground line 24V 24V of solenoid valve power line 0V 0V of solenoid valve power line M3 terminal screw in use. EX##-OMF0012 8 EX##-OMF0012-A No.EX-OMF0012-B -9- 5-3. Address setting (1) ADDRESS NO.
Tighten the wiring screws (M3 slotted head screws) firmly with a tightening torque of 0.5 to 0.6 Nm. Be sure to connect a "Terminating resistor" to both ends of transmission line. (Refer to Fig. 2). Tighten the connector fixing screws (M2.5 slotted head screws) firmly with a tightening torque of 0.2 to 0.3 Nm.
Air flow adjustment switch Scale Air flow [m3/min] 1 0.19 2 0.46 3 0.66 4 0.80 4-4. Maintenance Warning Function and Cleaning If the product is used for an extended period with dust present on the emitters, the product performance will be reduced.
SYJ7000 M3 0.8Nm Caution Replacement of Pilot Valve Pilot valve in this series are improved to provide excellent energy saving results. However following this improvement, these new valves are no longer compatible with the conventional pilot valve used at the interface.
See Fig. 4] For FN112-10, two screws are mounted in the middle of the guide assembly [M3 See Fig. 4] 2-6. The element can now be pulled out of the cover. Do not disassemble the element any further. Note) Reassembly should be performed by reversing the disassembly procedure. Refer to the schematic drawings for the assembly and disassembly procedures for the cover, seals etc.
Standard Strokes Stroke (mm) Bore size (mm) Bore size (mm) Mounting bracket Applicable switch Note 50 100 75 125 150 175 200 250 300 400 500 25 Switch mounting screw (M3 X 0.5 X 8 l ) Square nut 12 V V V V V V D-A7, A8 D-A7lH, A80H D-A73C, A80C D-A79W D-F7lV D-F7, J7 D-J79C D-F7lWV D-F79W, J79W 12 20 BQ-1 20 V V V V V V V V 32 V V V V V V V V V Switch mounting screw (M3 X 0.5 X 10 l )
Flow Rate: 4.2 CFM / 7.2 m3/hr / 119 LPM , 4.2 CFM / 7.2 m3/hr / 119 LPM, Max Vacuum: 25.4 in HgV / 115 Torr / -861 mbar , 25.4 in HgV / 115 Torr / -861 mbar, Horsepower (60 Hz): .4, Voltage (60 Hz): 115, Voltage (50 Hz): 115, Frequency (Hz): 50 / 60, Phase: 1-phase, Item Dimensions: Length: 8.66 in / 220 mm Width: 5.98 in / 152 mm Height: 6.14 in / 156 mm
Flow Rate: 4.2 CFM / 7.2 m3/hr / 119 LPM , 4.2 CFM / 7.2 m3/hr / 119 LPM, Max Vacuum: 25.4 in HgV / 115 Torr / -861 mbar , 25.4 in HgV / 115 Torr / -861 mbar, Horsepower (60 Hz): .4, Voltage (60 Hz): 200 - 277 / 346 - 480, Voltage (50 Hz): 200 - 255 / 346 - 400, Frequency (Hz): 50 / 60, Phase: 3-phase, Item Dimensions: Length: 8.66 in / 220 mm Width: 5.98 in /
Flow Rate: 2.4 CFM / 4.2 m3/hr / 68 LPM , 2.4 CFM / 4.2 m3/hr / 68 LPM, Max Vacuum: 25.4 in HgV / 115 Torr / -861 mbar , 25.4 in HgV / 115 Torr / -861 mbar, Horsepower (60 Hz): .2, Voltage (60 Hz): 115, Voltage (50 Hz): 115, Frequency (Hz): 50 / 60, Phase: 1-phase, Item Dimensions: Length: 8.07 in / 205 mm Width: 5.98 in / 152 mm Height: 5.91 in / 150 mm
Flow Rate: 4.2 CFM / 7.2 m3/hr / 119 LPM , 4.2 CFM / 7.2 m3/hr / 119 LPM, Max Pressure: 14.5 PSIG / 1 bar , 14.5 PSIG / 1 bar, Horsepower (60 Hz): .4, Voltage (60 Hz): 115, Voltage (50 Hz): 115, Frequency (Hz): 50 / 60, Phase: 1-phase, Item Dimensions: Length: 8.66 in / 220 mm Width: 5.98 in / 152 mm Height: 6.14 in / 156 mm , Length: 8.66 in / 220 mm,
Flow Rate: 2.4 CFM / 4.2 m3/hr / 68 LPM , 2.4 CFM / 4.2 m3/hr / 68 LPM, Max Pressure: 14.5 PSIG / 1 bar , 14.5 PSIG / 1 bar, Horsepower (60 Hz): .19, Voltage (60 Hz): 115, Voltage (50 Hz): 115, Frequency (Hz): 50 / 60, Phase: 1-phase, Net Weight: 14.3 lbs. / 6.5 Kg Series Configured Datasheet.
Flow Rate: 5.6 CFM / 9.6 m3/hr / 159 LPM , 5.6 CFM / 9.6 m3/hr / 159 LPM, Max Vacuum: 25.4 in HgV / 115 Torr / -861 mbar , 25.4 in HgV / 115 Torr / -861 mbar, Horsepower (60 Hz): .59, Voltage (60 Hz): 115, Voltage (50 Hz): 115, Frequency (Hz): 50 / 60, Phase: 1-phase, Item Dimensions: Length: 9.8 in / 249 mm Width: 6.14 in / 156 mm Height: 6.14 in / 156 mm
Flow Rate: 7 CFM / 12 m3/hr / 198 LPM , 7 CFM / 12 m3/hr / 198 LPM, Max Vacuum: 25.4 in HgV / 115 Torr / -861 mbar , 25.4 in HgV / 115 Torr / -861 mbar, Horsepower (60 Hz): .6, Voltage (60 Hz): 200 - 277 / 346 - 480, Voltage (50 Hz): 200 - 255 / 346 - 400, Frequency (Hz): 50 / 60, Phase: 3-phase, Net Weight: 22.7 lbs. / 10.3 Kg Series Configured Datasheet.
Flow Rate: 2.4 CFM / 4.2 m3/hr / 68 LPM , 2.4 CFM / 4.2 m3/hr / 68 LPM, Max Vacuum: 25.4 in HgV / 115 Torr / -861 mbar , 25.4 in HgV / 115 Torr / -861 mbar, Horsepower (60 Hz): .2, Voltage (60 Hz): 230, Voltage (50 Hz): 230, Frequency (Hz): 50 / 60, Phase: 1-phase, Net Weight: 14.33 lbs. / 6.5 Kg Series Configured Datasheet.