Error Name Error Display Error Type Troubleshooting Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Error name Error display Error type Troubleshooting method Turn the power off and remove the cause of the over current. Then turn the power on.
Do not cut the insulator. Insert the corresponding wire colour shown in the table into the pin number printed on the sensor connector, to the bottom.
Function Setting Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Mounting screw Function selection mode Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not touch the leakage of fluid without care. If the fluid has high temperature or is chemical, the contact could result in burn and other injuries. 3) Disassembly Do not disassemble the pump. Caution 1) Quality of supplied air Mount the filter with filtration of approx. 0.01.
Do not twist the valve seal 1.
Reset content Item Reset content PS1 0kPa PS2 0kPa *(Note): Gain (GL and sensitivity (SL) are not reset. 24 - Error indicating function Error LED display Contents of error Countermeasure name Please execute "initialize (refer to P33)" when ITV do not operate normally after restarting the power supply. Please contact us, when ITV do not operate normally after initialize.
Do not use lead wire retainers for unclamp angles of 105 , 120 and 135 . Failure example 1 There should be no slack in the lead wire. Lead wire retainers Failure example 2 Do not use the lead wire retainer above the switch. Lead wire Close the cover until you hear a click, and put the excess lead wire in the lead wire storage space.
Do not use any other voltage as this may cause failure. Before mounting the sensor to the cylinder, stop the operation of the device to avoid injury. Do not use the product if there is smoke or a strange smell. Do not handle with wet hands. Avoid getting the product wet. In case of a malfunction, stop using immediately. This product is a piece of precision equipment.
With regards to a breathing port Do not plug a breathing port. Also take care not to prevent intrusion of foreign matters such as dust and water into the breathing port. Mounting Warning About ventilation If air leakage increases or equipment does not operate properly, stop operation.
Wrapping of sealant tape When connecting pipes and fittings, etc. be sure that chips from the pipe thread and sealing materials do not get inside the valve. Furthermore, when pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads.
Warning Handling (1) Do not use for oxygen. (2) Do not give any modification to the product and its function. (3) Before installation and removal, shut off supply pressure completely and exhaust residual pressure in tubing and other pressure line. -6- Environment Caution (1) Do not mount the product in a location where it is subject to strong vibrations and/or shock. (2) Avoid to expose the
Do not twist the valve seal 1.
When multiple heater assemblies or valves are used, do not apply power to the heater assemblies simultaneously. Keep approximately 30 seconds between applications of power to each heater assembly. This will allow for incremental spacing to prevent harmful large initial surge. 8 XL*-OMI0011-E 4.
Do not operate at pressures or temperatures, etc. beyond the range of specifications, as this can cause damage or malfunction. (Refer to specifications.) Contact SMC when using a fluid other than compressed air (including vacuum).
B Z + Stroke DB DX DD 90 B 4-DT A DS DH 4-DR DL DU DO DO DC DE DU DA Rotating Angle Bore size (mm) Part no.
Therefore, do not loosen or remove the hexagon socket head cap screws which secure cover A and cover B. 2. Be sure to contact SMC regarding disassembly or repair, etc. D-X Individual -X 779
How to Order XC4 With heavy duty scraper Specifications: Same as standard type Dimensions: Same as standard type Caution Do not replace heavy duty scrapers. Since heavy duty scrapers are press-fit, do not replace the cover only, but rather the entire rod cover assembly. Made to Order Related Products 150 CP96 Series Symbol -XC7 Tie-rod, Tie-rod Nut, etc.
Our pressure switches do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. 3. Do not use in an environment where static electricity can cause problems, otherwise system failure or malfunction may result. 1. Do not drop, bump, or apply excessive impacts (980 m/s2) while handling.
Do not drop or bump. When handling the switch, do not apply an excessive impact (1000 m/s2) by dropping or striking the switch. Even if the switch case itself does not become damaged, it could damage the internal switch and cause it to malfunction. 2. Hold the product from the body side when handling. To handle the product, hold it by its body.