SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-41-06-M5T"

For details, please contact SMC. 3-11-17 18 Manifold Specifications Standard Specifications ISO Size 1 ISO Size 2 ISO Size 1 Maniflod block size VSR/S8-6 VSR/S8-8 VSR/S8-6 Applicable solenoid valve 1 to 10 Number of stations 1/4, 3/8, 1/2, 3/4, 1 A, B port Port size 1/4, 3/8, 1/2, 3/4, 1 P , EA, PB port VV82-P-03/04/06 VV81-P-02/03/04 Individual SUP spacer VV82-R-03/04/06 VV81-R-02/03/04

Base (4 stations), Common EXH, 100 VAC, DIN terminal, A/B port: Rc 3/4 VVP460-041-06 1 pc. VP4154-001D 2 pcs. VP4254-001D 1 pc. XT038N-4A 1 pc. Precautions No manifold is available for Series VP470. The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

R ZZM 06 06 R Multi-ejecter Common SUP port location Port and silencer location Series ZM Manifold Nil Both sides Number of stations R Right side L Left side B Both sides Right side Left side R L 01 1 station Right or left to the VAC port Right or left to the VAC port 05 5 stations Common EXH port size 10 10 stations (Max.) 04 06 1 2 3 4 Thread type S Silencer for ZZM (ZZM-SA) Nil Rc NPTF

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com R L 10 8 5 4 ZZMA Stations 06 ZL 10 10 8 6 ZZMA Stations 06B ZY R L 10 8 5 4 ZZMA Stations 04 ZQ 10 10 8 6 ZZMA Stations 04B Effective area of external silencer is 160 mm2. ZF ZP ZCU How to Order Ejector Manifold AMJ ZZMA 06 06 R Misc.

Note2) Fixed units: Instantaneous flow rate: L/min Accumulated flow: L Nil N Lead wire with M12 connector (3 m) Without lead wire Port size Applicable model Flow rate (L/min) Symbol 100 4 16 40 03 04 06 10 3/8 1/2 3/4 1 PF2W704, PF2W720 PF2W720, PF2W740 PF2W740, PF2W711 PF2W711 Output specifications 27 67 NPN open collector 2 outputs PNP open collector 2 outputs Specifications PF2W720

Note) 4 6 8 10 12 23 04 06 08 10 12 3.2 TMH-23J TMH-04J TMH-06J ASV Body size AS1001F AS2001F AS2051F AS3001F AS4001F AK TMH-06 TMH-08 ASS TMH-10 TMH-12 Applicable tubing Inch Size ASR Note) Mounting bracket is not available. This is an application example. Applicable tubing size ASF 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 Can be mounted on the panel.

How to Order VCHR 06 30 G Body size Thread type (Conforming to ISO1179-1 on the pneumatic/hydraulic G thread) 30 40 Symbol Port size Port size VCHR30 VCHR40 Symbol 06 10 14 3/4 1 11/2 630 Series VCHR Direct Operated Regulator for 6.0 MPa (Relieving Type) Specifications Model VCHR30 VCHR40 Valve construction Piston type Valve material Polyurethane elastomer Relief mechanism Relieving type

VBA VBAT AP100 841 VEX13 Series 0 3 Specifications VEX1A33 VEX1B33 VEX113 0 3 VEX123 0 3 VEX133 0 3 VEX153 0 3 VEX173 0 3 VEX193 0 3 Model Port 1(P) 2(A) 3(R) M5 01 M5 01 01 02 01 02 03 02 04 04 06 10 12 14 10 20 1 8 1 8 1 8 1 4 1 8 1 4 1 4 3 8 1 2 1 2 3 4 2 1 1 1 1 1 Port size M5 M5 1 2 4 1 4 1 2 Operation Manual knob (Push locking slotted type) and Air operated type Manual knob (Push locking

ASD Body size Port size M5 M5 x 0.8 U10/32 10-32UNF 1 M5 x 0.8 10-32UNF AS AS-FE 2 F A 1 AS 1 M5 06 0 E KE Body size 1 AS-FG F A 1 AS 2 01 06 2 0 S Body size 2/3/4 AS-FP AS-FM Body size Made to Order Refer to page 562 for details.

)) Flow rate (L/min (ANR)) 10,12 08 06 Number of needle rotations Number of needle rotations 712

Body size Port size M5 M5 x 0.8 U10/32 10-32UNF 1 M5 x 0.8 10-32UNF AS 2 0 F A 1 1 M5 06 G Body size 1 AS 2 0 S F A 1 2 01 06 G Body size 2/3/4 Body size Made to Order Refer to page 678 for details. 2 1/8, 1/4 3 3/8 4 1/2 Push-lock type Type 2 Elbow 3 Universal Seal method Nil Without sealant S With sealant Note) Face seal method is used for the G thread type.

)) Flow rate (L/min (ANR)) 10,12 08 06 Number of needle rotations Number of needle rotations 712

(Nominal size) Port size Hydraulic fluid Material 04 06 08 10 12 16 20 24 28 32 04 06 08 10 12 16 20 24 28 32 AL-128H AL-129H AL-131H AL-132H AL-134H AL-135H AL-136H AL-137H KA00813 (V120) AL-128H-V AL-129H-V AL-131H-V AL-132H-V AL-134H-V AL-135H-V AL-136H-V AL-137H-V KA00728 (V120) KA00815 (V85) KA00812 (V100) KA00813 (V120) KA00814 (V150) KA01800 (V175) KA00731 (V85) KA00727 (V100) KA00728

Model symbol (In-line filters) Element size 125mm 65 x 250mm Bore size 04 06 Rc 1/2 Rc 3/4 2.

T 04 06 08 10 12 4 6 8 10 12 VMG Construction Description Material Component Parts No. q w e r t y u i o !0 !

KPQ/KPG Series Clean One-touch Fittings How to Order KP H 06 KP P 08 Q 01 KQ2 Applicable fitting size Clean One-touch fittings Made to Order KQB2 04 06 08 10 12 4 6 8 10 12 Specifications X53 With pipe tape Grease-free Symbol Q G KS KX Specifications (metal part materials) Brass (electroless nickel plated) Stainless steel 304 Rubber material: EPDM (Fluorine-coated) X193 Note 1) Gasket: M-

AR20(K)-D,AR20M(K)-D AW20(K)-D,AWM20-D,AWD20-D AR30(K)-D,AR30M(K)-D AW30(K)-D,AWM30-D,AWD30-D AR40(K)-D,AR40M(K)-D,AR40(K)-06-D AW40(K)-D,AWM40-D,AWD40-D,AW40(K)-06-D AR50(K)-D AR60(K)-D,AW60(K)-D AR24P-580AS 0.02kg AR34P-580AS 0.04kg 0.05kg -5oC to 60oC AR44P-580AS AR54P-580AS 0.10kg 4Structural Drawing Lock Cover Knob Cover (Two parts) -6- 5How to attach (1) Press in the regulator handle

Symbol 0 1 2 Port size Port size Applicable model Symbol FQ1010 FQ1011 FQ1012 04 06 10 Rc1/2 Rc3/4 Rc1 Housing O-ring material Industrial Filters Replacement Procedure Actuators Modular F.R.L.

Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l Port size Applicable model Flow rate (l/min) Nil N M12 3 m lead wire with connector Without lead wire Symbol 100 40 4 16 03 04 06 10 3/8 1/2 3/4 1 PF2W704, PF2W720 PF2W720, PF2W740 PF2W740, PF2W711 PF2W711 Output specification 27 67 NPN open collector 2 outputs PNP open collector 2 outputs Specifications PF2W720 PF2W704