Body Type: T (Body Ported), Valve Option: E (Continuous Duty), Voltage: 3 (110VAC, 50/60 Hz), Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: None, Port Size: 02 (1/4, 8A), Thread: N (NPT)
Body Type: T (Body Ported), Valve Option: Standard, Voltage: 7 (240 VAC, 50/60 Hz), Electrical Entry: G (Grommet, 300mm Lead), Light & Surge Suppressor: None, Port Size: 02 (1/4, 8A), Thread: T (NPTF)
Body Type: T (Body Ported), Valve Option: Standard, Voltage: 5 (24 VDC), Electrical Entry: G (Grommet, 300mm Lead), Light & Surge Suppressor: S (Surge Voltage Suppressor), Port Size: 02 (1/4, 8A), Thread: T (NPTF)
Body Type: T (Body Ported), Valve Option: Standard, Voltage: 6 (12 VDC), Electrical Entry: G (Grommet, 300mm Lead), Light & Surge Suppressor: S (Surge Voltage Suppressor), Port Size: 02 (1/4, 8A), Thread: T (NPTF)
Body Type: T (Body Ported), Valve Option: E (Continuous Duty), Voltage: 3 (110VAC, 50/60 Hz), Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: S (Surge Voltage Suppressor), Port Size: 02 (1/4, 8A)
Body: T (Body Ported), Valve Specification: Non (Standard), Port Size: 02 (1/4), Voltage: 6 (12 VDC), Electrical Entry: C (Conduit), Surge Voltage Suppressor: None, Manual Override: None (Non-Locking Type), Thread: T (NPTF)
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: C (N.C. Float Type Auto Drain), Attachment: T (T-Interface), Semi-Standard 1: 3C (3 + C), Semi-Standard 2: RZ (R + Z)
Body Size: 25, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 02 (1/4), Option: DG (D + G), Attachment: T (T-Interface), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Size: 01(Size 26mm), Stations: 9 Stations, A, B Port: 02 (Side, 1/4), Port Thread: T (NPTF), SI Unit: SDQ (Serial Kit for DeviceNet™), End Plate: w/o SI Unit/End Plate, SI Unit COM: N (-COM), Number of Input Blocks: 0 (w/o Input Block), Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block
Size: 01(Size 26mm), Stations: 5 Stations, A, B Port: 02 (Side, 1/4), Port Thread: T (NPTF), SI Unit: SDZEN (EtherNet/IPâ„¢), End Plate: w/o SI Unit/End Plate, SI Unit COM: N (-COM), Number of Input Blocks: 0 (w/o Input Block), Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block
Series: 3 (VFA3000), Manifold: 30 (VFA1000 P,R Port Size: 1/8; VFA3000 P,R Port Size: 1/4), Stations: 02, Type: 1 (Common Exhaust)
Rated Flow Range: 02 (0.02 to 2 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve)
Model: 5 (10-SY5000), Actuation: 2 (2 Position Double), Pilot System: Internal Pilot, Coil Specification: Standard, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: G (Grommet, Lead Wire Length 300mm), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4 w/Sub-plate), Thread: T (NPTF)
Series: 544 (VP500), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: T (w/Power Saving Circuit, DC Only), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread Type: Rc, Actuation: A (N.C., Normally Closed)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: A3 (Bracket C)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: W (M8 Connector w/ Connector), Lead Wire Length: 7 (5000mm), Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: 02 (Body Ported 1/4, Base Mounted Sub-plate 1/4), Thread: T (NPTF)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: W (M8 Connector w/ Connector), Lead Wire Length: 4 (2000mm), Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: 02 (Body Ported 1/4, Base Mounted Sub-plate 1/4), Thread: T (NPTF)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 6 (12VDC), Electrical Entry: W (M8 Connector w/ Connector), Lead Wire Length: 7 (5000mm), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Style), A, B Port Size: 02 (Body Ported 1/4), Thread: T (NPTF)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: W (M8 Connector w/ Connector), Lead Wire Length: 7 (5000mm), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Style), A, B Port Size: 02 (Body Ported 1/4), Thread: T (NPTF)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: W (M8 Connector w/ Connector), Lead Wire Length: 7 (5000mm), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 02 (Body Ported 1/4), Thread: T (NPTF)