Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: M9PV, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: M9PV, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 6", Stroke(mm): 1", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: M9PV, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: DPC, Custom-made Specifications: Special port location
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: M9PV, Lead Wire Length(m): 0.5, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: NPT, Auto
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 20.9, Closed Dimension L2(mm): 14.9, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Cylindrical Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 30, Gripping Force (Open Side at 0.5 Mpa)(N): 40, Environment, Applications: Standard, Additional Function: Not Provided
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 20.9, Closed Dimension L2(mm): 14.9, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Cylindrical Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 30, Gripping Force (Open Side at 0.5 Mpa)(N): 40, Environment, Applications: Standard, Additional Function: Not Provided
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 26.3, Closed Dimension L2(mm): 16.3, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Cylindrical Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 41, Gripping Force (Open Side at 0.5 Mpa)(N): 66, Environment, Applications: Standard, Additional Function: Not Provided
How Grip: Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 33.3, Closed Dimension L2(mm): 19.3, Type: [Main Body] Body, Operation Method: Single Acting Type (Normally Closed), Main Body Shape: Cylindrical Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): -, Gripping Force (Open Side at 0.5 Mpa)(N): 82, Environment, Applications: Standard, Additional Function: Not Provided
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 33.3, Closed Dimension L2(mm): 19.3, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Cylindrical Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 68, Gripping Force (Open Side at 0.5 Mpa)(N): 100, Environment, Applications: Standard, Additional Function: Not
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 33.3, Closed Dimension L2(mm): 19.3, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Cylindrical Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 68, Gripping Force (Open Side at 0.5 Mpa)(N): 100, Environment, Applications: Standard, Additional Function: Not
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 10mm, Body Option: Standard, Locking Direction: Forwarding Stroke Lock, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, 0.5M, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -
Magnet: Built-in, Mounting: Double Clevis, Bore Size: 40mm, Thread: NPT, Stroke: 20mm, Body Option: Rod End Male Thread, Locking Direction: Retracting Stroke Lock, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, 0.5M, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -
Series: Standard w/ Magnet, Mounting: MF1, Front Flange, Bore Size: 1 1/2", Stroke: 60", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 2 pcs. (Or None in the Case
Series: Standard w/ Magnet, Mounting: MP1, Double Rear Clevis, Bore Size: 4", Stroke: 2", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Full Male, Threaded, Adjustment Range: Not Applicable, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -, X Option: -
Series: Standard w/ Magnet, Mounting: MF1, Front Flange, Bore Size: 4", Stroke: 2", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Full Male, Threaded, Adjustment Range: Not Applicable, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -, X Option: -
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20, 25
The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized