Body Size: 2 (1/8, 14), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FS, Thread: R (or None), Port Size: 01 (1/8), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 06 (ø6), Seal: without Sealant
Body Size: 2 (1/8, 14), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FS, Thread: R (or None), Port Size: 02 (1/4), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 06 (ø6), Seal: without Sealant
Body Size: 2 (1/8, 14), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FSG, Thread: G (G), Port Size: 01 (1/8), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 06 (ø6), Seal: without Sealant
Size: 5 (50), Valve Type: 1 (Normally Closed), Body Material: C (Brass), Seal Material: N (NBR), Port Size: 06 (Thread; 3/4), Thread Type: N (NPT), Rated Voltage: 1 (100 VAC), Electrical Entry: WN (M12 Connector/without Connector Cable; with Surge Voltage Suppressor)
Max Operating Pressure: 3 (3.5 MPa), Construction: 42 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 0 (None), Relief Valve: 1 (None), Fluid: 1 (Water-glycol, Emulsion), Element: P (Paper), Filtration: 20μm
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 1 (Differential Pressure Indicator), Relief Valve: 1 (None), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 10μm
Body Class: 2 (Orifice Dia. ø4), Valve Type: 0 (N.C.), Applicable Tubing Size: 06 (6 x 4), Pilot Port Thread Type: Rc 1/8, Pilot Port Position: None (Position 1), Material: FN (Body: PFA; End Plate: PVDF; Diaphragm: PTFE; Seal, Buffer: EPDM)
Body Size: 1 (M5 x 0.8, 10-32UNF), Control Type: 1 (Meter-in), Thread Type: R, Port Size: M5 (M5 x 0.8), Applicable Tubing O.D.: 06 (ø6), Seal Method: w/o Sealant, Option: Electroless Nickel Plating, Lock Nut Option: J (Round Lock Nut)
Body Size: 40, Thread: Rc, Port Size: 06 (3/4), Option: C (N.C. Float Type Auto Drain), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard
Body Size: 4 (1/2), Valve Option: V (Vacuum/Low Pressure), Port Size: 06 [3/4 (20A)], Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Light/Surge Suppressor: Z (Light/Surge Suppressor), Actuation Type: A (N.C., Normally Closed), Pilot: 1 (External Pilot)
Body Size: 4 (1/2), Valve Option: V (Vacuum/Low Pressure), Port Size: 06 [3/4 (20A)], Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Light/Surge Suppressor: Z (Light/Surge Suppressor), Actuation Type: B (N.O., Normally Open), Pilot: 1 (External Pilot)
Body Size: 6 (1), Valve Option: for General, Port Size: 06 [3/4 (20A)], Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: Z (Light/Surge Suppressor), Actuation Type: A (N.C., Normally Closed), Pilot: 1 (External Pilot), Thread: N (NPT)
Body Size: 4 (1/2), Valve Option: for General, Port Size: 06 [3/4 (20A)], Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Light/Surge Suppressor: Z (Light/Surge Suppressor), Actuation Type: B (N.O., Normally Open), Pilot: 1 (External Pilot), Thread: N (NPT)
Body Size: 4 (1/2), Valve Option: V (Vacuum/Low Pressure), Port Size: 06 [3/4 (20A)], Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Light/Surge Suppressor: None, Actuation Type: A (N.C., Normally Closed), Pilot: 1 (External Pilot), Thread: N (NPT)
Body Size: 4 (1/2), Valve Option: V (Vacuum/Low Pressure), Port Size: 06 [3/4 (20A)], Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: None, Actuation Type: A (N.C., Normally Closed), Pilot: 1 (External Pilot), Thread: N (NPT)
Body Size: 6 (1), Valve Option: for General, Port Size: 06 [3/4 (20A)], Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Light/Surge Suppressor: Z (Light/Surge Suppressor), Actuation Type: B (N.O., Normally Open), Pilot: 1 (External Pilot), Thread: N (NPT)
Body Size: 6 (1), Valve Option: for General, Port Size: 06 [3/4 (20A)], Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Light/Surge Suppressor: Z (Light/Surge Suppressor), Actuation Type: A (N.C., Normally Closed), Pilot: 1 (External Pilot), Thread: N (NPT)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector)
Body Size: 50, Thread: N (NPT), Port: 06 (3/4), Option: C [Float Type Auto Drain (N.C.)], Attachment: T (T Spacer), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)