Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: JT (OUT1: Analogue 1 to 5 V - OUT2: Analogue 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: JT (OUT1: Analogue 1 to 5 V - OUT2: Analogue 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket
Size: 30 (3/8), Reverse Flow Function: None, Thread: Rc, Port Size: 03 (3/8), Accessory 1: D [Float Style Auto Drain (NO)], Pressure Gauge Angle: G1 (Mounting Angle 0°), Accessory 2: None, Option 1: None, Option 2: None, Option 3: None, B: B
mm, Width: .79 in / 20 mm, Height: .81 in / 20.5 mm, Net Weight: .07 lbs. / .03 Kg Series Configured Datasheet.
Function: 1 (2 Position Single), Body Style: 30 (Body Ported/Common Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted Style), Piping: Side, Port Size: 03 (Sub-plate Plug-in 1/8, Non Plug-in 3/8, Direct Ported P,A,B Ports 3),
Function: 1 (2 Position Single), Body Style: 20 (Body Ported/Individual Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: S (Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate Plug-in 1/8, Non Plug-in 3/8, Direct Ported P,A,B Ports
Actuation Type: 4 (3 Position Exhaust Center), Sealant: 0 (Metal Seal), Function: RY (External Pilot, Low Wattage 0.5W), Voltage: 5 (24VDC), Lead Wire: H (Grommet Lead Wire 1.5m), Light & Surge Suppressor: E (w/o Light w/Surge Suppressor), Manual Override: Non-locking Push Style, Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 03 (Rc3/8)
Series: 5 (VFA5000), Manifold: 21 (P.R Port Size 1/2), Stations: 03, Type: 1 (Common Exhaust)
Series: 5 (VFA5000), Manifold: 21 (P.R Port Size 1/2), Stations: 03, Type: 1 (Common Exhaust), Thread: 00N (NPT)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 10 (1), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 10 (1), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 10 (1), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 10 (1), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 10 (1), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 10 (1), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 10 (1), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only), Calibration Certificate: A (Made to Order)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 10 (1), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 10 (1), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 10 (1), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: A (Made to Order)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 10 (1), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)