Connection Thread Tightening Method Caution (1) Connection thread: M5 and 10-32UNF First, tighten by hand, then use a wrench appropriate for the hexagon flats of the body to tighten an additional 1/6 to 1/4 turn. A reference value for the tightening torque is 1 to 1.5 Nm. Note) Excessive tightening may damage the thread portion or deform the gasket and cause air leakage.
Otherwise, air leakage may result. 2) After screwing in the fittings, mount the M5 fitting assembly on the manifold base.
IDU Series 10-1 Safety instructions 10 1 IDX-OM-W028 Air Dryer 10 Specification for Option R IDU22E75E-23 IDU22E75E-30 Customer connection side Tightening torque : M5 (2.6Nm) Connector width : 9.5mm or less Applicable electrical wire1.25mm2 or more Customer connection side Tightening torque : M5 (2.6Nm) Connector width : 9.5mm or less Applicable electrical wire1.25mm2 or more L01,L02,L03
For safety, install an appropriate fuse and circuit breaker before use. 1) When using SMCs M5 fittings, follow the procedures below to tighten them. Connection thread: M5 First, tighten by hand, then use a suitable wrench to tighten the hexagonal portion of the body an additional 1/6 to 1/4 turn. The reference value for the tightening torque is 1 to 1.5 Nm 1.
For example, if -0.15 C is set here, the actual reference temperature for control is lower than the indicated SV by 0.15 C. 5.6 Preparation for facility water M5,M6 screws (bolts) or equivalent to the fix the product.
When installing this product with a bracket, secure it with M5 screws using the mounting holes on the bottom of the bracket. (The screws should be Protection film prepared by the user). Refer to "6. Dimensions" for details.
Applied voltage When connecting fittings to valves, tighten as indicated below. 1) M3, M5 types 1. When using SMC fitting, follow the guidelines below. After tightening by hand, tighten an additional 1/4 (M3), 1/6 (M5) turn with a tightening tool. However, if miniature fittings are used, tighten an additional 1/4 turn with a tightening tool after tightening by hand.
Rubber seal, spool valve: Grease Connection thread: M5 Mounting First, tighten by hand, then use a suitable wrench to tighten the hexagonal portion of the body an additional 1/6 to 1/4 turn. The reference value for the tightening torque is 1 to 1.5 Nm. 1.
M5 First, tighten by hand, then use a wrench appropriate for the hexagon flats of the body to tighten an additional 1/6 to 1/4 turn. A reference value for the tightening torque is 1 to 1.5 Nm. Note) Excessive tightening may damage the thread portion or deform the gasket and cause air leakage. Insufficient tightening may loosen the threads, or cause air leakage.
After screwing in the fittings, mount the M5 fitting assembly on the manifold base. (Tightening torque: 0.8 to 1.2 Nm) 3. Purchasing order is available in units of 10 pieces.
Recommended tightening torque: M5 added. Round type pressure gauge Applicable tool size correction. '18.3 C Added note of "piping". Corrected tightening torque.(Diaphragm assembly, square embedded pressure gauge, pressure gauge adapter and blanking plate.)
Use N NPT 5 AC100-240V M5,M6 screws (bolts) or equivalent to the fix the product. Note) Only HECR010 with AC200-240V Be sure to correctly tighten all screws to the required torque.
Installation of Ionizer 1) Installation with bracket When installing the Ionizer with a bracket, secure it with M5 screws using the mounting holes on the bottom of the bracket (The screws need to be prepared by the user). Refer to "6. Dimensions" for details. The angle adjustment range of the bracket is 45 degrees in direction A, and 90 degrees in direction B.
ZNR ZNR 4 2 2 4 5 DC: Double 3 3 Solenoid Valve (with M Connector) Comforming to ISO 15407-1 Series EVS1-01/1-02 Dimensions EVS1-01-FG-S-M0 117.5 75.5 27.5 (14 port) 27.5 (12 port) 10.5 (4 port) 10.5 (2 port) 14 4 2 12 12 26 35 45 14 Indicator light 5 1 3 Manual override 39 36.5 41.5 2-5.5 mounting holes 44 M12 connector 20 (12, 14 port) 10.5 (2, 4 port) 85.5 72.5 10.5 PE port 29 14 SMC M5
Bore d C B H NTJ-015A 10 16 8.1 9.2 7 8 3.2 4 M4 X 0.7 NTJ-010A M5 X 0.8 * Refer to p.1.3-12 for details of the mounting nut. (mm) ND NN Bore 10 16 A B C D F GA GB H MM NA NB S Z 0 0.022 0 0.022 15 12 14 4 8 8 5 28 M4 X 0.7 12.5 9.5 M8 X 1.0 46 74 75 8 15 18 20 5 8 8 5 28 M5 X 0.8 12.5 9.5 M10 X 1.0 47 10 Refer to p.1.3-8 to 1.3-10 for dimensions of each mounting bracket.
X 0.8 M22 X 1.5 20 23.5 29.5 36 5 37.5 43.5 50 6 Plug Mounting Style CJPS B C E G H K MM NN 5st 10st F 15st R 5st 10st S 15st W Q 5st 10st Z Bore (mm) 6 10 15 A 15st 7 12 13.9 6 12.5 19.5 26.5 8.5 9 3.5 M3 X 0.5 M10 X 1.0 9 18.5 25.5 32.5 3 27.5 34.5 41.5 3 10 19 22 6 14.5 21 28 12 12 3.5 M4 X 0.7 M15 X 1.5 13 20.5 27 34 4 32.5 39 46 5 12 27 31 7 16.5 22.5 29 19 14 4.2 M5 X 0.8 M22 X 1.5
Step 3) Screw in the accessory unlocking bolt (hexagon socket headcap screw 32: M3 x 8l, 40: M4 x 8l, 50: M4 x 8l, 63: M5 x 10l). 1. Piping port position, switch rail position, and by-pass piping position can be selected by the part number. However, if there is an error in ordering and changes to the positions are required, please note the following. a.
EA) 25 1.4 32 5.5 (mm) EA EB HA Size CRJU05 CRJU 1 6.6 5.6 33.8 6.5 5.6 35.8 7.5 3.1 (mm) Rotation angle Q S JC JD BA BD A BH J BB D JB H BE BG BI JA SD BC DD UU N BF CB W CA Size 32.4 21.5 43 90 CRJB05 13.5 M4 x 0.7 5 30 11 19.5 20 M4 x 0.7 5g6 3.5 14.5 6.5 17.1 7 5.8 3.4 9.5 10h9 28 12.5 3.5 5.5 4.5 43.4 27 54 180 37.4 24 48 90 CRJB 1 16.5 M5 x 0.8 6 35 14 23.5 22 M5 x 0.8 6g6 4.5 15.5
x 0.8 M5 x 0.8 Width across flats 8 6 12h9 9.2 4 4 8 16.5 10.5 9 2.5 Rod end nut part no.: NTJ-015A 9 Mini Free-mount Cylinder Series CUJ Proper Auto Switch Mounting Position for Stroke End Detection (6, 8, 10 common) D-F8N, F8P, F8B D-F9N, F9P, F9B When detecting extended stroke end When detecting retracted stroke end Note 2) 10mm or more 3 + Stroke length in mm 7 7 Stroke length in
Q+Stroke (NA) Cylinder form 12 16 (mm) d Bore size (mm) Standard stroke (mm) A B C E G GP H HA HG HN HP HT J JK L LD Slide Ball bushing 12 15, 25 8 4 16 25 7.5 50 34 6 14.5 34 33 18 M5 X 0.8 9.5 68 4.3 8.5 10 16 15, 25 9.5 5 18 29 6.5 65 40 6.5 16 39.5 39 21 M6 X 1 9.5 75 5.2 7.5 12 20 25, 50 11 6.5 25 36 8.5 80 46 9 18 44.1 45 24 M8 X 1.25 10 86 6.9 9.5 16 25 25, 50 11 6.5 25 40 8.5 90 54