(choked flow) Subsonic flow : Flow greater than the critical pressure ratio Standard condition : Air in a temperature state of 20C, absolute pressure 0.1 MPa (= 100 kPa = 1 bar), relative humidity 65%. It is stipulated by adding the abbreviation (ANR) after the unit depicting air volume.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) Note 4) For VFR600-FZ-06, ( ): VFR610-DZ-06 3-5-93 94 Series VFR6000 How to Order Option Electrical entry Nil Z None With light/surge voltage suppressor F: Plug-in type, conduit type Not applicable to grommet terminal.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) Note 2) This solenoid valve requires lubrication. Use turbine oil Class 1 (ISO VG32).
18-bit encoder (Resolution: 262144 p/rev) Power consumption [W] Note 11) Horizontal 45 65 65 Vertical 145 175 175 Standby power consumption when operating [W] Note 12) Horizontal 2 2 2 Vertical 8 8 8 11LEFS 11LEJS Max. instantaneous power consumption [W] Note 13) 445 724 724 Type Note 14) Non-magnetizing lock Holding force [N] 131 255 485 157 308 588 197 385 736 Power consumption [W] at 20C
De-energized, Initial value) ZL1 Series ZL3/ZL6 Series With vacuum pressure detection port Supply Valve/Release Valve Specifications Model SYJ5m4 Port exhaust Response time (at 0.5 MPa)*1 25 ms or less Max. operating frequency 5 Hz Manual override Non-locking push type, Push-turn locking slotted type *1 Based on JIS B 8419: 2010 dynamic performance test (Standard type: Coil temperature 20C
due to ambient temperature. 7-4 Air flow capacity Model IDF1E IDF2E IDF3E IDF4E 50Hz 0.085 0.12 0.18 0.26 Air flow capacity m3/min(ANR) Note1) 60Hz 0.1 0.14 0.21 0.29 Outlet air temp. oC 10 Model IDF6E IDF8E IDF11E IDF15E1 50Hz 0.32 0.5 0.65 1.2 Air flow capacity m3/min(ANR) Note1) 60Hz 0.375 0.55 0.75 1.3 Outlet air temp. oC 10 Note1) The data for ANR is referring to the conditions of 20C
Insulation resistance Mkm, 20C (68F) 5 or more 16 44 8 SMC Connector manufacturers Fujitsu Ltd. Japan Aviation Electronics Industry, Ltd. J. S. T. Manufacturing Co., Ltd.
Conductor resistance /km, 20C 65 or less Note) When using the negative COM specification, use valves for negative COM. Withstand pressure V, 1 minute, AC 1000 Special wiring specifications (options) Insulation resistance M/km, 20C 5 or more Note) The minimum bending radius for D-sub connector cables is 20mm. (For 25P) Mixed single and double wiring are available as options.
Fluoropolymer Fittings Hyper Fitting / Flare Type Series LQ3 K M H KK D MS LQ MQR T Flare type collet construction Triple-seal Excellent heat resistance 200C compatible Ease of installation Excellent flow-through characteristics Model Feature LQ310 LQ320 LQ330 LQ340 LQ350 LQ360 LQ370 Material New PFA Maximum operating pressure (at 20C) 1.0 MPa Nut material PVDF 0 to 150C Operating temperature
LQ2 E 31 32 Different dia. tubing size (B side) Applicable tubing size (A side) Union elbow 17-5-113 18 Series LQ2 Specifications Model Feature LQ230 LQ220 LQ240 LQ250 NEW PFA Material Maximum operating pressure (at 20C) 1.0 MPa Refer to the withstand pressure and heat resistance performance curves.
Note) Insulation resistance M/km, 20C For other commercial connectors, use a 25 pins type with female connector conforming to MIL-C-24308. The minimum bending radius of D-sub cable assembly is 20 mm. 5 or less Positive common specifications Negative common specifications As the standard electrical wiring specifications, double wiring (connected to SOL. A and SOL.
ASD330F CM2 VZ500 TU0604 1 m AN11001 25 Cylinder size 32 Values at 0.5 MPa and 20C.
(Coil temperature : 20C, at rated voltage and without surge voltage suppressor) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
Property 65 or less Cable length (L) Conductor resistance /km, 20C AXT100-MC26-015 AXT100-MC26-030 AXT100-MC26-050 1.5 m 3 m 5 m Cable 25-core x 24AWG 10 Voltage limit V, 1 minute, AC 1000 Cannot be used for transfer wiring.
Property 65 or less Cable length (L) Conductor resistance /km, 20C AXT100-MC26-015 AXT100-MC26-030 AXT100-MC26-050 1.5 m 3 m 5 m Cable 25-core x 24AWG 10 Voltage limit V, 1 minute, AC 1000 Cannot be used for transfer wiring.
Characteristic Cable length (L) Multicore vinyl cable 0.3mm2 X 25C Conductor resistance /km, 20C Voltage limit V, 1min, AC 65 or less 1.5m 3m 5m AXT100-DS25-015 Cable 25 core X 24AWG AXT100-DS25-030 10 1000 AXT100-DS25-050 Insulation resistance M/km, 20C 5 or more For other commercial connectors, use a 25-pin female connector made in conformity with MIL-C-24308.
. *2 10 to 500 Hz for 2 hours in each direction of X, Y, and Z (De-energized, Initial value) *3 3 times in each direction of X, Y, and Z (De-energized, Initial value) Weight Supply Valve/Release Valve Specifications *1 Based on JIS B 8419: 2010 dynamic performance test (Standard type: Coil temperature 20C, at rated voltage, without surge voltage suppressor) * Refer to the Web Catalog for
Heat generation amount Q : Unknown : 1.0C (1.0 K) : 20C (293.15 K) : 21C (294.15 K) : 7 L/min :Water : Density : 1 x 103 kg/m3 Circulating fluid temperature difference T (= T2 T1) Circulating fluid outlet temperature T1 Circulating fluid inlet temperature T2 Circulating fluid flow rate L Circulating fluid : Specific heat C: 4.2 x 103 J/(kgK) T1: Outlet temperature Q = T x L x x C 60 x 1000
Incremental type 14.5 mT 10.8 to 13.2 VDC (Ripple less than 1%) 40 mA 0.1 mm/pulse 0.2 mm Note) (at 20C) NPN open collector (35 VDC, 80 mA) A/B phase difference output 500 VDC, 50 M or more (between case and 12E) 33.3 Hz, 2 hours at X, Y and 4 hours at Z JIS D 1601 as standard 30 G, 3 times at X, Y, Z IP50 (IEC standard) Maximum transmission distance Position detection method Magnetic field