Magnet: D (Built-in), Mounting: E (Double End), Bore Size: 32mm, Stroke: 200mm, Cushion: C (Air Cushion), Rod Boot: Standard, Switch Mounting: B (Band), Stainless Steel: XC6A (Stainless Steel Piston Rod, Piston Rod Nut)
Magnet: Built-in Magnet, Mounting: Basic Style, Bore Size: 100mm, Stroke: 200mm, Rod Boot: w/o Rod Boot, Rod: Single Rod, Pivot Bracket: No Bracket, Rod End Bracket: No Bracket, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: w/Lock
Size: 16, Motor Mounting Position: In-line, Motor Type: Step Motor (Servo/24 VDC), Lead Screw: LEY16: 2.5mm; LEY25: 3mm; LEY32/40: 4mm, Stroke: 200mm, Motor Option: w/Motor Cover, Rod End Thread: Female Rod End, Mounting: Ends Tapped (Standard), Actuator Cable Type: w/o Cable, Cable Length: w/o Cable, Controller/Driver Type: LECP1, NPN, Programless Type, I/O Cable Length: -, Protocol: -,
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: -, Auto Switches: Without auto switch,
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Magnet: Built-in, Mounting: Double End, Bore Size: 32mm, Stroke: 200mm, Cushion: Air Cushion, Rod Boot: Standard, Switch Mounting: Band, Stainless Steel: Stainless Steel Piston Rod, Piston Rod Nut
Magnet: Built-in, Series: Standard, Head Cover Type: Basic Integrated Clevis, Bore Size: 12mm, Stroke: 200mm, Cushion: Air Cushion, Rod Boot: None, Mounting Bracket: None, Accessory: None, Auto Switch Mounting Type: Band, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Piston Rod Variation: -
Magnet: Built-in, Series: Standard, Head Cover Type: Basic Integrated Clevis, Bore Size: 25mm, Stroke: 200mm, Cushion: Air Cushion, Rod Boot: None, Mounting Bracket: None, Accessory: None, Auto Switch Mounting Type: Rail, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Piston Rod Variation: -
Magnet: Built-in, Series: Standard, Head Cover Type: Basic Integrated Clevis, Bore Size: 25mm, Stroke: 200mm, Cushion: Air Cushion, Rod Boot: None, Mounting Bracket: None, Accessory: None, Auto Switch Mounting Type: Band, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 5m, Number: 1 pc., Piston Rod Variation: -
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: -, Auto Switches: Without auto switch,
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Bearing Type: Ball Bushing Bearing, Stroke: 200mm, Motor Option: w/Motor Cover, Actuator Cable Type: Standard Cable, Actuator Cable Length, m: 5, Controller Type: LECP1, Programless Type, PNP, I/O Cable Length, m: 5, Communication Plug Connector: None, Controller Mounting: Screw Mounting, Made to Order: Magnet/Switch Rail
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
CP96, profile design ISO cylinder with enclosed tie rods, is available in 6 bore sizes from ø32 to ø125mm. High accuracy covers and tie rod nuts improve mounting accuracy and extend the cylinder life. Increasing the precision of the bushing and piston rod, as well as reducing tolerances, has decreased the deflection of the piston rod. Standard strokes range from 25 to 800mm.Double Acting
Series LECP6 controller has two available modes for the setting software and teaching box.? In the easy mode, the operation can be started by only setting the speed, position, etc.? Using the normal mode allows a further detailed setup.??A few of the?main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, GC, 16MM LE ELECTRIC ACTUATOR, 3.74785 lb