Stations: 05, System, Port Combinations: Ejector System, Common PV: ø5/16", Inch Size, Exhaust: 2 [Vacuum Pump System, w/o Silencer; (Ejector System has Individual Exhaust Port)], Wiring: D-sub Connector, 25 Pins, Option: w/DIN Rail Mounting Bracket, Manifold Assembly, Delivery Condition: Delivered as Individual Parts, not Assembled

Stations: 05, System, Port Combinations: Vacuum Pump System, Common PV: ø8, Common PS: ø6, Metric Size, Exhaust: 2 [Vacuum Pump System, w/o Silencer; (Ejector System has Individual Exhaust Port)], Wiring: D-sub Connector, 25 Pins, Option: w/DIN Rail Mounting Bracket, Manifold Assembly, Delivery Condition: Delivered as Individual Parts, not Assembled

Stations: 05, System, Port Combinations: Ejector System, Common PV: ø8, Metric Size, Exhaust: 2 [Vacuum Pump System, w/o Silencer; (Ejector System has Individual Exhaust Port)], Wiring: D-sub Connector, 25 Pins, Option: -, Manifold Assembly, Delivery Condition: -

Stations: 05 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: Q (Vacuum Pump System), Pressure Switch for Vacuum/Pressure Sensor: E (Digital Pressure Switch for Vacuum, -100 to 100, NPN 2 Outputs, with Unit Selection Function), Leadwire: L (Standard Leadwires, X2), Unit Options: C [Vacuum Pump System PE Port Female

.: 03 (ø5/32"), Actuator Type: 05 (Straight Plunger), Suffix: None, Indicator: Z (w/Miniature Indicator)

Body Class: 2 (ø4 Orifice), Fitting Type: V, Tube Size: 05 (3/16"), Output Tube Size: None, Breathing Port Thread: Threaded, NPT1/8, Handle: 1 (90 Degree Turn Type)

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Model: LVH20 (Body Class 2, N.C.), Lever Operation: Non-locking, Self-reset, Tube Size: 05 (3/16")

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

CD-MU02 CD-MU03 CD-MU04 CD-MU05 0.040 0.076 0.040 0.076 0.040 0.076 0.050 0.093 8 10 10 14 NT-03 NT-MU03 NT-04 NT-05 One piece is included with the rod end male thread as standard. t 0.9 1.15 1.15 1.15 m 1.5 1.25 1.25 1.75 Snap ring C8 type for pivot C10 type for pivot C10 type for pivot C14 type for pivot Part no.

IZF10 C AC adapter AC adapter (AC cord attached) G1 AC adapter (Without AC cord) G2 IZS41 C AC adapter G1 G2 AC adapter (AC cord attached) AC adapter (Without AC cord) IZS41 CF Made to Order Transition wiring cable How to Order 05 08 Full length 8m Full length 5m Full length 2m 02 CF-X13 IZS41 Transition wiring cable length Symbol Cable full length 01 Full length 2m 02 Full length

O . auto drai n: M i n. 0. 1 M Pa O PERATI O N M AN U AL M i n. 0. 05 M Pa Keep f ol l ow i ng t o operat e M ai n l i ne f i l t er properl y. M ax. 1. 0 M Pa Fol l ow i ng envi ronm ent s l ead t o cause breakage. Envi ronm ent Low er t han 5 D o not use under f ol l ow i ng envi ronm ent . D o not use under f ol l ow i ng condi t i ons.

Symbol 2 3 4 Metric sizes 04 06 08 10 12 4 x 3 6 x 4 8 x 6 10 x 8 12 x 10 Symbol B A Inch sizes Basic size With reducer 03 05 07 11 13 1/8" x 0.086" 3/16" x 1/8" 1/4" x 5/32" 3/8" x 1/4" 1/2" x 3/8" Note 1) Applicable fittings: LQ2 Note 2) For details of the applicable tubing sizes, refer to page 945.

Applicable model LVR20 LVR40 LVR50 03 3 x 2 LVR20 LVR40 LVR50 03 1/8" x 0.086" 04 4 x 3 05 3/16" x 1/8" 06 6 x 4 07 1/4" x 5/32" 10 10 x 8 11 3/8" x 1/4" 12 12 x 10 13 1/2" x 3/8" 19 19 x 16 19 3/4" x 5/8" LQ3 Metric size Inch size Symbol Applicable tubing size Applicable model Symbol Applicable tubing O.D.

How to Order IZS31 CP X13 L (Tolerance 1%) Cable length 60 L: Cable length Symbol 7 01 02 04 05 06 07 08 09 11 12 13 14 15 16 17 18 19 20 1000 mm 2000 mm 4000 mm 5000 mm 6000 mm 7000 mm 8000 mm 9000 mm 11000 mm 12000 mm 13000 mm 14000 mm 15000 mm 16000 mm 17000 mm 18000 mm 19000 mm 20 mm (Red) 1 12 (6.2) 3 Cable Specifications No. of cable wire 12 0.14 mm2 (AWG26) 0.48 mm Nominal cross section

X14 1 1 1 1 2 2 3 3 4 5 7 7 IZD IZE IZH Drop prevention cover When attached to the body Transition wiring cable Remote controller/IZS41-RC IZS41 CF Transition wiring cable 02 05 08 Full length 2 m Full length 5 m Full length 8 m AC adapter For IZS40 IZF10 C AC adapter G1 G2 AC adapter + AC cord AC adapter (without AC cord) AC cord is only for use in Japan.

2.4 *1 Excluding the 20/20B(F)-L B A C B A C Pressure Pressure IO-Link: Process Data Relationship between the process data and pressure value ZSE20B-L (For vacuum pressure) ISE20B-L (For positive pressure) ZSE20BF-L (For compound pressure) Process data 5200 Process data Process data 5100 5200 5000 5000 5000 3000 1000 1000 Pressure [kPa] 1000 Pressure [kPa] Pressure [MPa] 600 580 900 10 1 .05