SMC Corporation of America
Elite Part Number Search
Search Results "VHS20-F02B-S"

S Short circuit detection Diagnostic function which detects generation of over current due to a short circuit between the output and the positive power supply line or the ground line. Short circuit protection Function which avoids damage to the internal circuit when over current is generated due to short circuit between the output and the positive power supply line or the ground line.

Fork lever assembly M P368010-24 Fork lever assembly S P368010-25 Fig.21 Example of side attaching Fig.22 Example of backside attaching B using fork lever assembly M using fork lever assembly S 27 In the case of side attaching, if you use fork lever assembly M, it is compatible with our IP610 positioner in the attaching size.

H 4 S y m b o l Initial power/ Power consumption (W) 100 VAC 600/150 800/220 1200/350 200 VAC 2400/150 3200/220 4800/350 Heater assembly number XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 No. of heater assemblies 2 pcs. 3 pcs. 4 pcs.

, excluding gas permeation Pam3/s External 1.3 x 10-11 for the standard material (FKM) at ambient temperatures , excluding gas permeation Flange type KF (NW) KF (NW), K (DN) Main material Body: aluminum alloy, Bellows: SUS316L, Main part: SUS304 and FKM (standard sealant material) Surface treatment for body Outside: hard anodized Inside: basis material Actuation pressure MPa(G) 0.4 to 0.7

S Set flow range The range of ON/OFF threshold values that can be set for products with a switch output. Reference condition for volumetric flow: 101.3 kPa, 20 C, 65%RH The flow measurement which is converted at normal atmospheric pressure conditions at 20 C, 65%R.H. Standard condition (ANR) An output type that has only 2 conditions, ON or OFF.

Time to reach 2,000rpm is the acceleration/deceleration time constant of 5[s] or less. Speed is 150rpm or higher. Load to motor inertia is 100 times or less. The acceleration/deceleration is 10% or more of the rated torque. 7 - 1.3.2 The recommended the parameter for each driver The recommended the parameter for each driver. Please change the parameter values by use of the customer.

Diagnostics type 2 Table. 5-6 Overview of Diagnostics type 2 Byte Description 0 General diagnostics 1 1 Valve diagnostics 1 2 General diagnostics 2 3 Valve diagnostics 2 General diagnostics 1 Table. 5-7 General Diagnostics 1 Bit Description Explanation 0 Maximum number of valves 0: 16 Valves 1: 32 Valves or no "Valves" module 1 Valve coil(s) short circuit 0: No valve coil(s) have a short

The kinetic energy of the load is calculated by the formula below. + = 4 . 1 = a V V 2 V m M E k 2 Ek: Kinetic energy (J) M : Mass of object being transported (kg) m : Mass of moving parts of cylinder (kg) V: Maximum speed (m/s) Va: Average speed (m/s) Mass of moving parts of cylinder (kg) Bore size Standard stroke (mm) (mm) model 20 25 30 40 50 75 100 125 150 175 200 250 300 350 MLGPM20

H 4 S y m b o l Initial power/ Power consumption (W) 100 VAC 600/150 800/220 1200/350 200 VAC 2400/150 3200/220 4800/350 Heater assembly number XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 No. of heater assemblies 2 pcs. 3 pcs. 4 pcs.

Replacement part/Grease pack part no.: GR-S-010 (10 g) 15 - 3-6. Construction / Parts list, seal list MHZAJ2-6 Double acting/ Finger open Single acting / Normal open Single acting / Normal closed Double acting/ Finger closed Components Components No. Description Material Remarks No.

Time s 0.150.2 s Ex.) For DC24. DC6 V specification, The time to apply starting voltage is same for all voltage. 4-2 XLS-**-P*G (with control power supply) Valve (9) opens when the coil assembly is applied the rated voltage. Valve (9) closes when the coil assembly is stopped being energized.

Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) For instructions on how to replace replacement parts/seals, refer to the operation manual. 106

Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) For instructions on how to replace replacement parts/seals, refer to the operation manual. 108

Grease pack part number: GR-S-010 (10 g)/GR-S-020 (20 g) 7 Wide Type Parallel Style Air Gripper MHL2 Series Dimensions MHL2-10DmZ 6 6 9 2 x M4 x 0.7 thread depth 5 (Mounting thread) D Closed J View K (Fingers closed) The above figure shows the MHL2-10D1Z/10D2Z.

Z 5 16.5 10 25.5 5 29 10 38 Bore (mm) Stroke 2.5 Bore size: 4/CJ1B4-lSU4 Symbol S Z 5 19.5 10 28.5 15 37.5 20 46.5 5 40 10 49 15 58 20 67 Bore (mm) Stroke 4 1.1-5 World Wide QS\E Support...

Nil S Number of fingers 2 fingers Nominal size 2 10 15 20 30 Auto switch Nil Without auto switch (Built-in magnet) Connecting port For the applicable auto switch model, refer to the table below. R: Body side E: Axial side Port Port Applicable Auto Switch/Refer to page 12-13-1 for further information on auto switches.

HAl Accessories (Options) HAA7 AT Auto drain Applicable Model HAA7 HAA15 HAA22 HAA37 HAA7-F AD402-03 HAA7-S HAA15-F AD402-03 HAA15-S HAA22-F AD402-03 HAA22-S HAA37-F AD402-04 IDl Dust protecting filter Mounting bench HAA37-S AMG How to Select (Flow Capacity l/min (ANR)) Operation Principle AFF Model HAA7 HAA15 HAA22 HAA37 AMl 50C 70C 100C 1000 1500 700 2200 4000 1500 3300 6000 2200 5700 13000