Width across flats 19 5 I 5 J 5 J Width across flats 12 Width across flats 12 Applicable tube O.D.
B P_1 or n_1 H_1 P_1=A(AB)/4 n_1=B+(AB)/4 H_1=(AB)/2 Released Workpiece 1 Workpiece 2 Workpiece n Atmosphere B Display value fine adjustment function (F6) Fine adjustment of the indicated value of the pressure sensor can be made within the range of 5% of the read value. (The scattering of the indicated value can be eliminated.) 5% R.D.
N.C. and N.O. common Noninductive load (A) Inductive load (A) Resistance load Light load Inductive load Motor load Rated voltage (V) Normally Normally Normally Normally Normally Normally Normally Normally closed open closed open closed open closed open AC125 AC250 DC8 DC14 DC30 DC125 DC250 5 5 5 5 5 0.4 0.3 1.5 1 0.7 0.5 4 4 2.5 1.5 1.3 0.8 3 3 3 0.1 0.05 3 3 3 0.1 0.05 5 4 Reset button 4
(n 2) 2 20 + 35 55 + 35 (n 2) (n = 2, 3, 4, 5) D-M9 5 20 CHQ 55 (n = 2, 4, 6) Note 3) (n 2) 2 55 + 35 (n 2) (n = 2, 3, 4, 5) 20 + 35 D-M9W 10 20 55 CHK (n = 2, 4, 6) Note 3) (n 2) 2 60 + 35 (n 2) (n = 2, 3, 4, 5) 25 + 35 D-M9A 10 25 60 CHN (n = 2, 4, 6) Note 3) (n 2) 2 50 + 35 (n 2) (n = 2, 3, 4, 5) 15 + 35 D-A9 5 15 50 CHM CHM (n = 2, 4, 6) Note 3) (n 2) 2 35 + 35 (n 2) (n = 2,
Applicable bore size (mm) CX Applicable snap ring Applicable snap ring A1 NDH10 MM NX R1 U1 Dd9 t d L m Dd9 t d L m l l + 0.048 0 0.030 0.060 0.030 0.060 I-J010SUS 10 CD-J010 10 CD-J010 10 3.3 3.3 3.3 Type C 3.2 Type C 3.2 8 21 M4 x 0.7 3.1 8 9 3 15.2 12.2 1.2 0.3 3 15.2 12.2 1.2 0.3 CY 0.030 0.060 0.030 0.060 + 0.048 0 I-J016SUS CD-Z015SUS IY-J015SUS 16 16 16 5 5 5 Type C 5 Type C 5 8 25
Applicable bore size (mm) CX Applicable snap ring Applicable snap ring A1 NDH10 MM NX R1 U1 Dd9 t d L m Dd9 t d L m l l + 0.048 0 0.030 0.060 0.030 0.060 I-J010SUS 10 CD-J010 10 CD-J010 10 3.3 3.3 3.3 Type C 3.2 Type C 3.2 8 21 M4 x 0.7 3.1 8 9 3 15.2 12.2 1.2 0.3 3 15.2 12.2 1.2 0.3 CY 0.030 0.060 0.030 0.060 + 0.048 0 I-J016SUS CD-Z015SUS IY-J015SUS 16 16 16 5 5 5 Type C 5 Type C 5 8 25
Analogue output 1 to 5 V Output impedance 1k Max.28 V, 80 mA Internal voltage drop 1 V max.
Check the Model Selection on catalog. *5 The speed and force may change depending on the cable length, load and mounting conditions, Furthermore, if the cable length exceeds 5 m, then it will decrease by up to 10% foy each 5 m.
to 30 20 to 30 10 to 30 20 to 30 10 to 30 Max. acceleration/deceleration[mm/s2] 5000 Positioning repeatability [mm] 0.01 Lost motion[mm] *4 0.1 or less Screw lead[mm] 10 5 2.5 12 6 16 8 Impact/Vibration resistance[m/s2] *5 50/20 Actuation type Ball screw (In-line) Ball screw + Belt (parallel) Guide type Linear guide (Circulating type) Operating temperature range[] 5 to 40 Operating humidity
Dimensions (RS-232C without optional unit) Driver 5 100 40 1-5 hole 5 5 5 120 130 5 5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Driver input/output signal list (CN-1/F connector) Driver dimensions Pin no. Pin no.
mass (kg) Work piece mass (kg) 5 10 10 5 5 1 1 1 0.5 5 40 30 20 10 5 40 30 20 10 5 40 30 20 10 Transfer speed V (m/min) Transfer speed V (m/min) Transfer speed V (m/min) 1420 Escapements Series MIW/MIS Model Selection Allowable lateral load MIW8 MIS8 MIW12 MIS12 0.7 MPa 70 0.7 MPa 30 0.6 MPa 0.6 MPa 0.5 MPa 60 0.4 MPa 0.5 MPa 0.3 MPa 0.4 MPa Lateral load F (N) Lateral load F (N) 50 RSQ 0.2
108 126 150 160.5 6 128 146 175 185.5 L1 L2 L3 L4 2.10-36 VQZ100/200/300 Base Mounted Manifold Options Blank plate VVQZ100-10A-5 VVQZ200-10A-5 VVQZ300-10A-5 This is used when removing the valve for maintenance, or reserving a valve mounting space on the manifold for future use.
M14 x 1 Hexagon width across flats 19 M5 x 0.8 5 5 20 D 5 F Hexagon width across flats 21 C Y 2.5 A B Dimensions (mm) A B C D F Y Model ZPT40F-B5-A14 40 43 12.5 18.5 51.5 5 ZPT50F-B5-A14 50 53 13.5 19.5 52.5 6 13-11-103 8 Vacuum Pad: Ball Joint Type Vertical Vacuum Entry Without Buffer/Female Thread Series ZPT How to Order ZPT 20 F GS B01 Vacuum entry/ Mounting thread diameter Pad diameter
Note 5) Note 5) Note 5) Note 5) Note 5) Z Note 5) Z Note 4) Note 1) Option B, G, H are not assembled and supplied loose at the time of shipment.
Stations 5 4 3 2 1 V114-5GZ 2 1 3 2 Blank plate assembly V100-77-1A Manifold base (5 stations) VV100-S41-05-M5 VV100-S41-05-M5 1 set (Type S41, 5 station manifold base part no.) V100-77-1A 1 set (Blank plate assembly part no.) V114-5GZ 4 sets (Valve) The asterisk () is used when referring to assembly. Enter the asterisk at the beginning of individual cmponent part numbers.
. i-3 i-2-6 . i-4 i-2-7 . i-4 i-2-8 . i-5 i-2-9 . i-5 i-3 . i-6 i-4 / . i-7 1 1-1 . 1-1 2 2-1 . 2-1 2-2 . 2-1 2-2-1 . 2-1 2-2-2 . 2-2 2-2-3 . 2-2 2-2-4 . 2-3 2-2-5 . 2-3 2-3 . 2-5 3 / 3-1 . 3-1 3-2 . 3-1 3-3 . 3-2 3-4 . 3-2 3-5 . 3-2 3-6 . 3-2 4 4-1 . 4-1 4-2 . 4-1 4-2-1 () . 4-1 1 4-2-2 . 4-1 4-2-3 . 4-2 5 5-1 . 5-1 6 6-1 . 6-1 6-2 GWP . 6-2 6-3 .
Checks and inspection 4 . 1 Daily check .4 1 4 . 2 Parts requiring regular maintenance.4 1 4. 2. 1 Maintenance of the water-cooled condenser.4 1 4. 2. 2 Caution for handling the Motor type auto drain .4 6 Chapter 5 Troubleshooting 5 . 1 Troubleshooting .5 1 5 . 2 Reset of protective equipment.5 3 Chapter 6 References 6 . 1 Specification table .6 1 6 . 2 Outer dimensions .6 2 6 . 3 Electric
3 2 Chapter 4 Maintenance 4 1 Daily inspection . 4 1 4 2 Periodical Maintenance . 4 1 4 2 1 Cleaning of ventilation grille (suction grille) . 4 1 4 2 2 Service parts . 4 1 4 2 3 Cleaning of auto drain strainer . 4 2 4 2 4 Replacement of bowl assembly . 4 2 Chapter 5 Troubleshooting . 5 1 5 1 Cause and countermeasure of errors . 5 1 Table of Contents 1 Air Dryer Table of Contents Chapter 6