Magnet: Built-in Magnet, Series: J2, Mounting: Basic, Bore Size: 16, Stroke: 100mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 1m, Number: 1 pc., Auto Switch Mounting Type: Band Mounting, Made to Order Option: Fluororubber
Magnet: Built-in Magnet, Series: J2, Mounting: Basic, Bore: 16mm, Stroke: 15mm, Cushion: Air Cushion, Head Cover Port Location: Axial, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting
Magnet: Built-in Magnet, Series: J2, Mounting: Basic, Bore: 16mm, Stroke: 150mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc., Auto Switch Mounting Type: Band Mounting
Magnet: Built-in Magnet, Series: J2, Mounting: Basic, Bore: 16mm, Stroke: 150mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc., Auto Switch Mounting Type: Band Mounting
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: A93, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: A90, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9N, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: A90, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: H7B, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9BA, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9B, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: H7BA, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: M9B, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: H7A2, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: H7B, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: H7A2,
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: H7A2,
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, Cushion: Air cushion, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet, Auto Switches: C73, Lead
HS Auto switch Auto switch 12 8.5 24.5 16 A B A B 33 38.2 Auto switch mounting position Auto switch mounting height (mm) (mm) Auto switch model D-C7, C8 D-H7 D-H7W D-H7F D-H7BA D-H7 D-H7C D-H7W D-H7BA D-C7, C8 D-C73C D-C80C D-B5, B6 D-C73C D-C80C D-B5, B6 D-B59W D-G5NT D-H7C D-G5NT D-B59W D-H7F Bore size (mm) A A B A B A A HS HS HS B B B B A 20.5 (28.5) 14.5 (22.5) 17.5 (25.5) 19.5 (27.5)
Port size (P, A and B port) Rated voltage M5 M5 x 0.8 01 Rc 1 8 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz R1, R2: M5 4 Option 5 6 24 VDC 12 VDC Nil None With bracket (Not assembled) 7 240 VAC, 50/60 Hz 9 Other Option F Option Part No. Description Part no.