SMC Corporation of America
Elite Part Number Search
Search Results "AC40C-N04CG-V-8Z-D"

Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)

Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)

Stations: 05 (5 Stations), Supply/Return Unit Layout: D (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.

Stations: 03 (3 Stations), Supply/Return Unit Layout: D (U Side: Open; D Side: Open), Thread Type: F (G), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: Flow Adj.

Stations: 05 (5 Stations), Supply/Return Unit Layout: D (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: W (w/Flow Adj.

Stations: 10 (10 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 20 (2 to 16 L/min), Return Unit Components: Flow Adj.

Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: S (w/Flow Adj.

Stations: 08 (8 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: Rc, Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: P (w/o Flow Adj.

Stations: 06 (6 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2 to 16 L/min), Return Unit Components: S (w/Flow Adj.

Stations: 03 (3 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: Rc, Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj.

The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. Filter regulator and mist separator , Clean looking, modular design , Energy

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FR/MS COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, FC, AC MASS PRO 1/2 MODULAR (NPT), 4.07854 lb, ModelComponentPort sizePressure gauge port size Note 1)FluidAmbient and fluid temperature Note 2)Proof pressureMaximum operating pressureMinimum operating pressureSet pressure rangeRelief pressureNominal

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, F/R COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, FC, AC MASS PRO 1/2 MODULAR (NPT), 3.58775 lb, ModelComponentPort sizePressure gauge port size Note 1)FluidAmbient and fluid temperature Note 2)Proof pressureMaximum operating pressureSet pressure rangeRelief pressureNominal filtration ratingBowl

The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. Filter regulator and mist separator , Clean looking, modular design , Energy

SMC's new AC series of modular type F.R.L. unit is available in 4 sizes and is interchangeable with the existing modular type AC line.  The element and bowl on the AW and AF series is now one-piece, making element replacement easier.  Required maintenance space has been reduced by as much as 46% on the AF series, depending on the body size.  Bowls on size 30 or more are now covered with

The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with h, F/R COMBO MODULAR, MODULAR F.R.L., 0.8 lb

Combining a mist separator and regulator into one unit simplifies piping and installation. This combination controls the filtration to 0.3 m, for applications that require cleaner air than regular filtration, such as air blow off. As part of the family of modular air preparation units, the AWM can be combined with other similar sized products. This series is available with port sizes from