Size: 63, Motor Type: S3 [AC Servo Motor (Incremental Encoder) 200W], Stroke: 2000mm, Motor Option: None, Cable Type: S (Standard), Cable Length: 5m, Driver Type: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input), I/O Connector: 1 (1.5m)
Size: 40, Motor Type: S2 [AC Servo Motor (Incremental Encoder) 100W], Stroke: 800mm, Motor Option: None, Cable Type: S (Standard), Cable Length: 5m, Driver Type: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input), I/O Connector: H (Connector)
Size: 40, Motor Type: S2 [AC Servo Motor (Incremental Encoder) 100W], Stroke: 1200mm, Motor Option: None, Cable Type: S (Standard), Cable Length: 2m, Driver Type: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input), I/O Connector: H (Connector)
Size: 63, Motor Type: S3 [AC Servo Motor (Incremental Encoder) 200W], Stroke: 1000mm, Motor Option: None, Cable Type: S (Standard), Cable Length: 5m, Driver Type: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input), I/O Connector: H (Connector)
Size: 63, Motor Type: S3 [AC Servo Motor (Incremental Encoder) 200W], Stroke: 500mm, Motor Option: None, Cable Type: S (Standard), Cable Length: 2m, Driver Type: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input), I/O Connector: 1 (1.5m)
Size: 40, Motor Type: S2 [AC Servo Motor (Incremental Encoder) 100W], Stroke: 500mm, Motor Option: None, Cable Type: S (Standard), Cable Length: 5m, Driver Type: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input), I/O Connector: 1 (1.5m)
Size: 63, Motor Type: S3 [AC Servo Motor (Incremental Encoder) 200W], Stroke: 2000mm, Motor Option: None, Cable Type: S (Standard), Cable Length: 2m, Driver Type: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input), I/O Connector: H (Connector)
Size: 63, Motor Type: S3 [AC Servo Motor (Incremental Encoder) 200W], Stroke: 3000mm, Motor Option: None, Cable Type: S (Standard), Cable Length: 5m, Driver Type: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input), I/O Connector: H (Connector)
Size: 63, Motor Type: S3 [AC Servo Motor (Incremental Encoder) 200W], Stroke: 500mm, Motor Option: None, Cable Type: S (Standard), Cable Length: 5m, Driver Type: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input), I/O Connector: 1 (1.5m)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only, Fixed Unit: kPa, MPa), Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only, Fixed Unit: kPa, MPa), Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)]
Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]
Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B (ZS-46-A2)]
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B (ZS-46-A2)]
Pressure Range: 0.0 to -101.0kPa, Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: No Lead Wire, Adapter: None, Calibration Certificate: K (w/Certificate)
Pressure Range: F (-100.0 to 100kPa), Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan)
Pressure Range: F (-100.0 to 100kPa), Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 connector type), Bracket: A5 (Bracket E for M12 Connector Type)
Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Accuracy: ±2% F.S., Port Size: N01 [NPT 1/8 (w/M5 Female Thread)], Output Specification: L (IO-Link/Switch: 1 output), Lead Wire Termination: S (With M12-4 pin connector, 500 mm)