Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
L D d m t d H B C l 0.040 0.076 0.050 0.093 32, 40 C type 10 for shaft NT-04 IY-G04 32, 40 41.6 9.6 36.2 1.55 1.15 M14 x 1.5 8 22 25.4 C type 14 for shaft 10 50, 63 NT-05 IY-G05 50, 63 50.6 13.4 44.2 2.05 1.15 M18 x 1.5 11 27 31.2 14 Retaining rings are included.
Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: B (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F), Bracket: None, Calibration Certificate: A (Calibration Certificate
Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Return Unit Flow Range: 04 (0.5 to 4 L/min), Supply/Return Port Size: 03 (3/8)
Stations: 02 (2 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 02 (2 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: P (w/o Flow Adj.
Function: 2 (2 Position Double), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: M (M Plug Connector w/Lead Wire 300mm), Light/Surge Suppressor: U (With light/surge voltage suppressor (Non-polar type)), Manual Override: Non-locking Push Type, Port Size: 04 (1/2), Thread: N (NPT)
Function: 2 (2 Position, Double), Model: 0 (Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 1 (100 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 04 (1/2)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F), Bracket: None, Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: Rc, Port Size: 03 (3/8), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: R (Bracket)
Rated Flow Range: 501 (5 to 500 L/min), Thread Type: Rc, Port Size: 04 (1/2), Output Specifications: A (Out 1: NPN; Out 2: NPN), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: R (w/Bracket), Calibration Certificate: A (Yes)
Stations: 8 Stations, Port Size: 04 (1/2), Thread: N (NPT), SI Unit: SQA (DeviceNetâ„¢ - 32 Outputs - Connector M12), SI Unit COM: N (-COM)
Base Mounted Wiring: 10 (Non Plug-in Individual Lead Wire Entry), Stations: 05 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2), Thread: N (NPT)
Function: 1 (2 Position Single), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 1 (Direct Manual Override), Pilot: Internal Pilot, Voltage: 7 (240VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 04 (Sub-plate Plug-in
Actuation Type: 6 (3 Position Double Check), Sealant: 0 (Metal Seal), Function: Standard (1W), Voltage: 5 (24VDC), Lead Wire: H (Grommet Lead Wire 1.5m), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style, Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2)
AMJ 30 0003 2R ZR ZM Body size Pressure gauge position 30 3/8 None Bracket Nil ZH 40 1/2 B Option 50 3/4 ZU Drain cock Nil Metal bowl 2 ZL Thread type Port size Nylon bowl 6 Drain guide (Rc 1/4) 02 1/4 Nil J Rc ZY 03 3/8 F Flow: Right Left R G 04 1/2 N If ordering two options or more, indicate symbols numerically and alphabetically.
Stations: 04 (4 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: W (w/Flow Adj.
Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: W (w/Flow Adj.