The recommend life time of the mechanical seal before needing replacement is 6000 to 8000 hours (usually 1 year) Check point to see leakage Fig. 8-3 Check for water leakage from pump HRS Series 8.2 Inspection and Cleaning 8-5 HRX-OM-R016 Chapter 8 Control, Inspection and Cleaning 8.2.5 Inspection for winter season Prevention of freezing of circulating fluid The product can prevent freezing
The recommend life time of the mechanical seal before needing replacement is 6000 to 8000 hours (usually 1 year) Panel Pump Fig. 8-3 Leak check HRL Series 8.2 Inspection and Cleaning 8-5 HRX-OM-X037 Chapter 8 Control, Inspection and Cleaning 8.3 Operation Stop for an Extended Period of Time If there is a concern that the product will not be operated for an extended period of time or there
The recommend life time of the mechanical seal before needing replacement is 6000 to 8000 hours. Leakage was found here Fig. 8-3 Check for water leakage from pump HRSH Series 8.2 Inspection and Cleaning 8-5 HRX-OM-R026 Chapter 8 Control, Inspection and Cleaning 8.2.5 Inspection for winter season The power supply should be ON for these functions. Otherwise these functions cannot start.
www.stevenengineering.com I S E E I N S I D E F R O N T C O V E R F O R DETAILS OF YOUR LOCAL SALES OFFICE 2.66 SOLENOID VALVES SERIES NVFS SERIES NVFS 2000, 3000, 4000, 5000, 6000 5 PORT PILOT OPERATED BASE-MOUNTED / PLUG-IN TYPE Large Flow Capacity Low Power Consumption Long Life Ease Maintenance Many Variations Available M O D E L NVFS2000 S Y M B O L S Position Port Size Number Of Type
The recommend life time of the mechanical seal before needing replacement is 6000 to 8000 hours (usually 1 year) Check point to see leakage Fig. 8-3 Check for water leakage from pump HRS Series 8.2 Inspection and Cleaning 8-5 HRX-OM-M090 Chapter 8 Control, Inspection and Cleaning 8.2.5 Inspection for winter season Prevention of freezing of circulating fluid The product can prevent freezing
Series LC1 controller (vertical specification) Description Part no. 57026-5000 (for UL1007) 57027-5000 (for UL1015) Crimping tool 57031-6000 Puller 87 91 Series LC7R Brake Wiring Example A wiring example for controller (Series LC1) connectors and a brake is shown below. The brake is in a de-energized condition and locked. 24VDC is required to unlock it.
CY36 Consult with SMC in case a bracket with mass exceeding the above value is to be mounted. 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1000 2000 3000 4000 5000 6000 CY315 Note 1) According to the dead weight deflection in the figure on the right, provide clearance so that the cylinder does not touch the mounting surface or the load, etc., and is able to
Description 57026-5000 (for UL1007) 57027-5000 (for UL1015) Crimping tool Puller 57031-6000 307 Series LC6D Connection Examples Electrical wires Wiring numbers 0.5mm or larger (AWG18 to 20) 0.2mm or larger (shielding wire) (AWG18 to 24) For open collector output Series LC6D + 5VDC CW input 330 7 3 +24V + Receptacle side (female terminal insertion side) 24VDC CW 10 6 GND 330 2 CCW input
30 AP 1 1 1 1 Minimum command unit 1pulse AL 1 1 1 1 AD75P AM 1 1 1 1 Electronic gear AP 4000 20 6000 30 Minimum command unit 0.1 m AL 1000.0[ m] 1000.0[ m] 1000.0[ m] 1000.0[ m] AM 10 10 10 10 Note.
(a) 200V class servo motor 25 73 Time constant [ms] 20 23 S7 15 10 053 S5 13 S6 5 43 S8 00 1000 2000 3000 4000 5000 6000 Speed [r/min] LE--series 10 5 10. CHARACTERISTICS 10.3.2 The dynamic brake at the load inertia moment Use the dynamic brake under the load inertia moment ratio indicated in the following table.
rate (l/min (ANR)) Thread type Nil N F Rc NPT G AK4000-03/-04 AK6000-06/-10 Port size 0.5 MPa 0.5 MPa Port size Applicable series AK2000 AK2000/4000 AK4000 AK4000 AK6000 AK6000 Inlet pressure: 0.1 MPa Inlet pressure: 0.1 MPa 0.3 MPa 0.3 MPa 0.7 MPa 0.7 MPa 01 02 03 04 06 10 1 8 1 4 3 8 1 2 3 4 1 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 15-14-1 2 Series AK Construction AK2000 AK4000/6000
150 110, 120, 125, 150, 175, 200 20, 25, 32 10 to 100 225, 250, 275, 300 (CXWM16 to 25) 225, 250 (CXWM32) 225, 250, 275 (CXWL16 to 25) 225 (CXWL32) CXWM 16, 20, 25, 32 25 to 200 CXWL 16, 20, 25, 32 225, 250, 275 25 to 200 ML1 25, 32, 40 1001 to 2000 100 to 1000 CY3B 20, 25, 32, 40 2001 to 3000 100 to 1000 CY1B 50, 63 From 2001 200 to 2000 2001 to 4000 (25, 32) 2001 to 5000 (40) 2001 to 6000
Description 57026-5000 (for UL1007) 57027-5000 (for UL1015) Crimping tool Puller 57031-6000 307 Series LC6D Connection Examples Electrical wires Wiring numbers 0.5mm or larger (AWG18 to 20) 0.2mm or larger (shielding wire) (AWG18 to 24) For open collector output Series LC6D + 5VDC CW input 330 7 3 +24V + Receptacle side (female terminal insertion side) 24VDC CW 10 6 GND 330 2 CCW input
CXWL 225, 250, 275 (CXWL16 to 25) 225 (CXWL32) MY2H/HT 50 to 600 601 to 1500 (Up to 1000 for 16) 16, 25, 40 ML1 100 to 1000 1001 to 2000 25, 32, 40 MY3A MY3B MY3M 16, 25, 40, 63 100 to 2000 2001 to 3000 2001 to 3000 (25 to 40) 2001 to 5000 (50, 63) CY3B 25, 32, 40, 50, 63 100 to 1000 10 to 75 80, 90, 100, 110, 120, 125, 150 10 200 to 1000 2001 to 4000 (25, 32) 2001 to 5000 (40) 2001 to 6000
Bracket Weight Model CY36 CY310 CY315 CY320 CY325 CY332 CY340 CY350 CY363 0.2 0.4 1.0 1.1 1.2 1.5 2.0 2.5 3.0 C (Note) CY3B50,63 CY3B25,32,40 CY3B20 CY3B15 Clearance (Note) CY3B10 (0.2 to 0.5 mm) CY36 Consult with SMC in case a bracket with weight exceeding the above value is to be mounted. 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1000 2000 3000 4000 5000 6000
Standard Stroke Bore size (mm) Standard stroke (mm) Manufacturable Note) maximum stroke (mm) 6 300 50, 100, 150, 200 10 500 50, 100, 150, 200, 250, 300 50 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 6000 63 Note) Please contact SMC if it is used by exceeding the maximum stroke length.
63) 25, 32, 40, 50, 63 100 to 1000 10 to 100 20, 25, 32 10 15 20 25 100 to 300 100 to 500 100 to 600 100 to 800 301 to 500 501 to 750 601 to 1000 801 to 1200 10, 20, 30, 40, 50 75, 100, 125, 150 10, 15 CY1H CXSW 10, 20, 30, 40, 50, 75, 100 125, 150, 175, 200 20, 25, 32 ML1 25 32 1001 to 1200 1001 to 1500 25, 32, 40 100 to 1000 1001 to 2000 2001 to 4000 (25, 32) 2001 to 5000 (40) 2001 to 6000
Series LC1 controller (vertical specification) Description Part no. 57026-5000 (for UL1007) 57027-5000 (for UL1015) Crimping tool 57031-6000 Puller 87 16 Series LC7R Brake Wiring Example A wiring example for controller (Series LC1) connectors and a brake is shown below. The brake is in a de-energized condition and locked. 24VDC is required to unlock it.
Nominal size Pitch Compression Tension JB40-8-125 JB63-10-150 JB80-16-200 JB100-20-250 JB140-22-250 20, 25 32 40 50, 63 80 8 10 16 20 22 29 35.5 47.5 59 71.5 1.25 1.5 2 2.5 2.5 51 62.5 80.5 101 129 8.5 10 16 21 18 13 15 18 24 38 11 13 20 26 22 31 41 50 59.5 79 6 7.5 9.5 11.5 14 11 14 19 24 30 0.15 0.29 0.56 1.04 2.6 11 13.5 16 20 22 22 27 32 41 46 0.75 1 1.25 2 2.5 1300 3100 5000 7900 15300 6000
(a) 200V class servo motor 25 73 Time constant [ms] 20 23 S7 15 10 S5 053 S6 13 5 43 S8 00 1000 2000 3000 4000 5000 6000 Speed [r/min] LE--series 12.3.2 The dynamic brake at the load inertia moment Use the dynamic brake under the load inertia moment ratio indicated in the following table. If the load inertia moment is higher than this value, the built-in dynamic brake may burn.