as possible in order to prevent condensation on the outlet piping and temperature increase on the outlet due to ambient temperature. 7-4 Dryer specifications Models IDFB3E IDFB4E IDFB6E IDFB8E IDFB11E Air flow rate (ANR) 5SCFM (8 m3/h) 13SCFM (23 m3/h) 17SCFM (29 m3/h) 19SCFM (32 m3/h) 23SCFM (39 m3/h) Outlet air temp. 50 F (10C) The data for ANR is referring to the conditions of 68 F (20C
FGH Series EJ Specifications EJS-013 EJS-006 EJS-004 Model EJS-002 Filtration accuracy(Filtration efficiency 99%) 13 6 4 2 2490 2090 2310 1890 117 mm Length Filtration area (cm2) 5600 4700 5200 4250 246 mm 11200 9400 10400 8500 496 mm Heat resistant temperature (C) 80 Filter media Polyester Material Reinforcement material Polypropylene Others Polypropylene Pressure resistance 0.5 MPa at 20C
(Coil temperature: 20C, at rated voltage) SX3000 With light/surge voltage suppressor Response time (ms) (at the pressure of 0.5 MPa) Type of actuation Without light/surge voltage suppressor S, Z type 15 or less 2 position single 10 or less 13 or less 2 position double 15 or less 20 or less 3 position 12 or less SX5000 With light/surge voltage suppressor Response time (ms) (at the pressure
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) When operating the locking type manually, apply torque of 0.2 Nm or less. Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
cooling Refrigerant R134aHFC(WGP:1300) Refrigerant Charge Quantitiy 150 5g 200 5g 230 5g 270 5g 290 5g 3505g Air IN/OUT Connection Rc3/8 Rc1/2 Rc3/4 Rc1 Acceesory (Hexagon nipple) R3/8 R1/2 R3/4 R1 Drain Connection (Outside Diameter of Tubing) 10mm Color Panel: Urbanwhite1Base:Urbangray2 Weight 18kg 22kg 23kg 27kg 28kg 46kg Note1: The data for m3/ (ANR) is referring to the conditions of 20C
FGH Series EJ Specifications EJS-013 EJS-006 EJS-004 Model EJS-002 Filtration accuracy(Filtration efficiency 99%) 13 6 4 2 2490 2090 2310 1890 117 mm Length Filtration area (cm2) 5600 4700 5200 4250 246 mm 11200 9400 10400 8500 496 mm Heat resistant temperature (C) 80 Filter media Polyester Material Reinforcement material Polypropylene Others Polypropylene Pressure resistance 0.5 MPa at 20C
Insulation resistance Mkm, 20C 5 or less 16 44 8 SMC Connector manufacturers example Fujitsu, Ltd. Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd.
Port size Symbol Port size 10 R1 Specifications FND100V-10-M149X0 Model FND100N-10-M149X0 R1 Port size Bowl & Cover Stainless steel 304 O-ring Material NBR FKM Element Stainless steel 304 149 m Element nominal filtration rating Weight 7.5 kg Note) Produced upon receipt of order. 2 Series FN1/FN4 Flow Characteristics (Initial Value) P Test fluid: Potable water P Liquid temperature: 17 to 20C
.: 1/2 inch [Thread symbol: N], 12 mm [Thread symbol: Nil]) Drain tube holder, Operation manual Compliant standards UL, CSA Refrigerated air dryer Auto drain 1 The operating range does not guarantee use with normal air flow capacity. 2 Air flow capacity under the standard condition (ANR) [atmospheric pressure 68F (20C), relative humidity 65%] 3 When the operating conditions are different
The valve can be used at ambient temperatures as low as 20C, but take measures to prevent freezing or solidification of impurities, etc. 2. When used in cold areas, adopt freeze prevention measures such as draining the water from pipelines. If warmed with a heater, etc., avoid the coil unit.
The product can be used at an ambient temperature as low as 20C, but take measures to prevent the solidification or freezing of impurities, etc. 2. When using for water, etc. in a cold area, devise a means to prevent freezing, such as draining the water from pipelines after stopping supply and exhaust water for a pump or other device.
Standard condition: Flow rate converted to a volume at 20C and 1 atm (atmosphere) Normal condition: Flow rate converted to a volume at 0C and 1 atm (atmosphere) * Also, the increase or decrease of the flow and temperature will not change the on/off status of the output while the forced output function is activated.
The unit conversion between SI and conventional units are as follows: Oscillation acceleration 100m/s2 = 10.1972G Pressure 1MPa = 10.1972kgf/cm2 Cylinder thrust/load 100N = 10.1972kgf Standard air: Symbol (ANR) Torque 1Nm = 10.1972kgfcm Temperature 20C {293K}, Air with Moment of inertia 1kgm2 = 10.1972kgcm/s2 an absolute pressure of 760 mmHg Kinetic energy 1J = 10.1972kgcm {101.3kPa}, and
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
65 65 Vertical 145 175 175 Standby power consumption when operating [W] Note 10) Horizontal 2 2 2 Vertical 8 8 8 Electric specications Max. instantaneous power consumption [W] Note 11) 445 724 724 Type Note 12) Non-magnetizing lock Holding force lbf [N] 29 [131] 57 [255] 109 [485] 35 [157] 69 [308] 132 [588] 44 [197] 87 [385] 165 [736] Lock unit specications Power consumption [W] at 68F (20C
A 10 () (+) White Black Conductor resistance /km, 20C Station 10 65 or less SOL. B 23 () (+) Gray Red 11 () (+) White Red SOL. A Withstand pressure V, 1 minute, AC Station 11 1000 SOL. B 24 () (+) Black White 12 () (+) Yellow Red SOL. A Insulation resistance M/km, 20C Station 12 5 or less SOL. B 25 () (+) White None Note) The minimum bending radius for D-sub connector cables is 20mm.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
Note Conductor resistance /km, 20C 65 or less 1.5 m 3 m 5 m AXT100-DS25-015 Cable 25 cores x 24AWG AXT100-DS25-030 Withstand limit VAC, 1 minute 1000 AXT100-DS25-050 For other commercial connectors, use a 25 pin type with female connector conforming to MIL-C24308. Insulation resistance Mkm, 20C 5 or less Note) The minimum bending radius of the D-sub connector cable is 20 mm.
Item Conductor resistance /km, 20C Characteristics Cable length (L) Assmbly part no. Note Connector manufacturers example Hirose Electric Co., Ltd. Sumitomo 3M Limited Fujitsu Limited Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg.