Note EVS Manifold block assembly VZ1000-1A-1 q D side For D side, with D-sub connector and P/R port with One-touch fitting for 6 SUP/EXH block assembly SUP/EXH block assembly VZ1000-2A-1D w VFN For U side, with D-sub connector and P/R port with One-touch fitting for 6 DIN rail VZ1000-2A-1U e End block assembly End block assembly For D side For U side Without D-sub connector For indicated
9, D-T99 D-9A, D-S99, S9P High precision type MSUA 90 3 Single vane 7 180 D-R73, D-T79 D-R80, D-S79, S7P 20 1 D-9, D-T99 D-9A, D-S99, S9P 90 Single vane 3 MSUB Double vane 180 7 D-R73, D-T79 D-R80, D-S79, S7P 20 Double vane is available with 90 rotation setting only.
D-J79 D-C73C D-C80C D-H7C (16) D-F7V D-J79C (16) D-F7W D-J79W D-F7BAL D-F79F D-H7LF D-F7WV D-F7BAVL D-F7LF In addition to the models in the above table, the following auto switches are also applicable.
D-M9mW D-M9mA D-M9mV D-M9mWV D-M9mAV U A B [mm] Auto Switch Proper Mounting Position [mm] Auto Switch Mounting Height D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA D-M9mAV A B 12 5 2.5 16 5.5 3 20 6 6 25 6 7.5 32 8 8 40 11 9 50 11.5 11 63 13.5 13.5 80 16.5 18 100 19.5 21 Auto switch model Auto switch model D-M9mV Bore size Bore size U 12 19.5 16 21 20 23 25 24.5 32 28.5 40 31.5 50 36.5 63 43 80 52.5
Applicable bore (mm) A D L MM N R W B C H d Applicable bore (mm) Part no.
Note Manifold block assembly C6: A, B port with One-touch fitting for 6 C8: A, B port with One-touch fitting for 8 C6 C8 VQ7 VZ5000-50A-1q (a) Bolt (Both sides) For D side, With D-sub connector and P/R port with One-touch fitting for 10 For U side, With D-sub connector and P/R port with One-touch fitting for 10 SUP/EXH block assembly VZ5000-51A-1D w EVS D side SUP/EXH block assembly End block
K: Non-rotating D-D B B Width across flats 19 Width across flats 19 D D D D 22 28 A B 50 5 5 22 28 A B 50 5 5 M14 x 1 M8 x 1.25 Gasket M8 x 1.25 Gasket M14 x 1 Width across flats 21 Width across flats 21 50 4 50 4 4.5 4.5 Dimensions Dimensions Part no.
Applicable bore (mm) A D L MM N R W B C H d Applicable bore (mm) Part no.
Example Data Theoretical Output Minimum Stroke for Auto Switch Mounting OUT IN (N) (mm) Rod size (mm) Operating direction Piston area (mm2) Operating pressure (MPa) Bore size (mm) D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 No. of auto switches mounted D-Y69 D-Y7PV D-Y7WV D-Y7BAL D-P5DWL 314 283 251 220 188 157 126 94 63 314 OUT 20 10 236 212 189 165 142 118 94 71 47
1008 1075 VCC-G-D-1 (Applicable fitting VCK ) VCC-G-D-1 2 13 Width across flats: 19 25.5 14 60 VCC-G-D-2 (Applicable fitting VCK ) 0806 0604 9 Width across flats: 17 20.5 14 50 For extending the socket VCC-G-D-1 VCC-G-D-1 113 VCC-G-D-1 VCC-G-D-2 97 17 VCC Series Disassembly/Assembly/ Maintenance Procedure Cleaning Valve Element Special tool part no.: VCC-G-C VCC13-00 (3 port valve) VCC12-
SMC Pneumatics, Inc. 8 Series ASIII1F-T Dimensions (mm) 1in=25.4mm L4 D3 Applicable tubing O.D. d L3 D1 L2 M1 M1 D2 L1 Metric sizes Inch sizes Model d D1 D2 D3 L1 L2 L3 L4 M1 M1 Model d D1 D2 D3 L1 L2 L3 L4 AS1001F-01T 1/8" 8.4 38 4.5 26 AS1001F-23T 3.2 8.4 38 4.5 26 12.7 12.7 AS1001F-03T 5/32" 9.3 39.2 5.2 26.6 AS1001F-04T 4 10 4.5 0.7 9.3 39.2 5.2 26.6 10 4.5 0.7 AS1001F-05T 3/16" AS1001F
Insert D at the end of the manifold part number.
Technical Data 1219 MY1H Series Auto Switch Mounting Auto Switch Proper Mounting Position Auto Switch Proper Mounting Position (mm) D-M9 D-M9V D-M9W D-M9WV D-M9AL D-M9AV Auto switch model D-A9 D-A9V A A Bore size A A 25 32 40 81 85 112.5 116.5 133.5 137.5 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
D U With Auto Drain S F W M 4 T BRACKET MOUNTING THREAD R C G J Q P K N 2 A H L E IN OUT Bracket (Optional) D NPT 1/4 5 Series AW20~40 Filter Regulator How To Order AW 30 N 03 D 8 Z X48 Filter Regulator With External Epoxy Coating, Stainless Fasteners Name Plate, Caution Plate On Bowl in psi, F Body Size Symbol 20 30 40 Size 1/8 3/8 1/2 Bowl Symbol 2 8 Applicable Body Size 20 30, 40 Description
Body tapped Model DReed auto switch D-A9, D-A9V 10 20 30 50 75 100 -X MXF8 8 Solid state auto switch D-M9, D-M9V MXF12 12 Individual -X 2-color indication solid state auto switch D-M9W, D-M9WV MXF16 16 MXF20 20 133 Series MXF Model Selection Model Selection Step Formula/Data Selection Example Operating Conditions 1 Cylinder: MXF20-50 Cushion: Rubber bumper Workpiece table mounting Mounting
D-DN This catalog is printed on recycled paper with concern for the global environment.
Note 3) Bowl assembly for the AL30 to AL60 models comes with a bowl guard (steel band material). 511 Series AL10 to AL60 Dimensions AL10 AL20 J M U T N S D Bracket (Option) A B C R B C Q IN OUT IN OUT OUT 2 x P (Port size) OUT 2 x P (Port size) Clearance for maintenance G Clearance for maintenance A G AL30, AL40 AL50, AL60 Bracket (Option) T N S T M U M U D J D J N S Bracket (Option) R B
Rz 12.5 45 Female thread size Chamfered dimension D (Recommended value) M5 5.1 to 5.4 10-32UNF 5.0 to 5.3 2. Use G external threads with G internal threads. D For Uni Thread 45 Tightening method 1.