By removing the two mounting screws from the desired valves, and rotating each valve body 180 and reassembling it on the manifold base, it is possible to reassemble an N.C. valve as an N.O. valve. (When doing so, make sure that the gasket is attached to the mounting surface of the valve.) Properly tighten the screws. The tightening torque of the mounting screws is 3 Nm.

temperature display accuracy 0.5oC (including accuracy of the sensor) Single phase Single phase Single phase Single phase Single phase Single phase Power supply 100VAC 200VAC 230VAC 100VAC 200VAC 230VAC (50/60Hz) (50/60Hz) (50/60Hz) (50/60Hz) (50/60Hz) (50/60Hz) Note 5) Operating current 4.2A 2.1A 2.1A 9.4A 4.8A 4.8A Electrical specifications Circuit Breaker 10A 5A 5A 15A 10A 10A Compressor input 180

By removing the two retaining screws from the desired valves, and rotating each valve body 180 and reassembling it on the manifold base, it is possible to reassemble an N.C. valve as an N.O. valve. (When doing so, make sure that a gasket is attached to the mounting surface of the valve.) Properly tighten the screws. The tightening torque of the retaining screws is 3 Nm.

If they are not aligned, the connector cannot be joined properly. (3) When the mark B of the connector has been turned 180 degrees (1/2 turn), wiring is completed. Confirm that the connection is not loose.

If they are not aligned, the connector cannot be joined properly. (3)When the mark B of the connector has been turned 180 degrees (1/2 turn), wiring is completed. Confirm that the connection is not loose.

If they are not aligned, the connector cannot be joined properly. (3)When the mark B of the connector has been turned 180 degrees (1/2 turn), wiring is completed. Confirm that the connection is not loose.

If they are not aligned, the connector cannot be connected correctly. (3)When mark B has been turned 180 degrees (1/2 turn), wiring is complete. Confirm that the connection is not loose.

If they are not aligned, the connector cannot be joined properly. (3)When the mark B of the connector has been turned 180 degrees (1/2 turn), wiring is completed. Confirm that the connection is not loose.

If they are not aligned, the connector cannot be joined properly. (3)When the mark B of the connector has been turned 180 degrees (1/2 turn), wiring is completed. Confirm that the connection is not loose.

Temperature 2 ~ 40oC(Relative Humidity of 85% or less) 100V AC(50/60Hz) Single phase AC100/100 , 110VVoltage fluctuations10% Power source 200V AC(50/60Hz) Single phase AC200/200 , 220V Electrical Specification Voltage fluctuations10% 100V AC(50/60Hz) 2.4/2.5 3.0/3.1 5.7/5.7 Operating current (Note 2) A 200V AC(50/60Hz) 1.2/1.3 1.5/1.5 3.4/3.0 Power consumption (Note 2) W 100V AC,200V AC (50/60Hz) 180

75 Min. speed [mm/s] (Independent and interpolation) 15 8 4 18 9 5 24 12 6 24 12 6 Min. speed [mm/s] (Speed tuning control ) 22 12 6 26 13 7 34 17 9 34 17 9 Supplement 1.2 Initial setting of LEFS series Model LEFS16 LEFS25 Lead symbol A B H A B Lead [mm] 10 5 20 12 6 Stroke (mm) 500 500 500 600 700 800 600 700 800 600 700 800 Max. speed [mm/s] 500 250 1000 900 630 550 500 420 330 250 230 180

75 Min. speed [mm/s] (Independent and 15 8 4 18 9 5 24 12 6 24 12 6 interpolation) Min. speed [mm/s] 22 12 6 26 13 7 34 17 9 34 17 9 (Speed tuning control) Supplement 1.2 Initial setting of LEFS series Model LEFS16 LEFS25 Lead symbol A B H A B Lead [mm] 10 5 20 12 6 Stroke [mm] 500 500 500 600 700 800 600 700 800 600 700 800 Max. speed [mm/s] 500 250 1000 900 630 550 500 420 330 250 230 180

(Not indicated during normal control.) 3 External Sensor Sampling 10 to 999sec (1sec) 180 Cycle Indicates the offset value of the circulating fluid temperature used as reference value by the controller (SV + Offset). -9.99 to 9.99 C (0.01 C) 0.00 4 Offset Value 5 Allowable Upper Sets upper limit of temp. range which causes the warning to arise. 0.1 to 10.0 C (0.1 C) 1.5 Temp.

MHZJ2-10 MHZJ2-16 MHZJ2-20 MHZJ2-25 Cylinder inside diameter (mm) 10 16 20 25 Fluid Air Double acting: D 0.2 to 0.7 0.1 to 0.7 Operating pressure (Mpa) Normally open: S 0.35 to 0.7 0.25 to 0.7 Normally Single acting closed: C Ambient and fluid temperature (oC) 10 to 60 Repeatability (mm) +/-0.01 Maximum operating frequency (c.p.m.) 180 Lubrication Lubrication not required.

Guide rod tightening torque direction Transfer 50, 63, 80: 5.2Nm Port Port Transfer direction Lever Position of lever: 0 Position of lever: 90 Guide rod Port position Port Port Transfer direction Screw for guide rod direction Transfer Figure-4 Position of lever: 180 Position of lever: 270 10 - 3-6.

(Not indicated during normal control.) 10 to 999sec 3 External Sensor Sampling Cycle (1sec) 180 Indicates the offset value of the recirculating fluid temperature used as reference value by the controller (SV + Offset). -9.99 to 9.99 C (0.01 C) 0.00 4 Offset Value 5 Allowable Upper Temp.

The Pressure switch can be assembled with rotated 180 degree. -25No.PS-OMJ0004-E Troubleshooting Applicable Pressure switch: ISE35 If a cause applicable to the failure cannot be identified and normal operation can be recovered by replacement with a new Pressure switch, this indicates that the Pressure switch itself was broken.

LEY100B Stroke[mm] Note 1) 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 Work load [kg] Horizontal Note 2) 1,200 1,200 240 Vertical 200 185 80 Force [N] Note3,4) 25 to 55% 5,500 3,300 1,100 ~12,000 ~7,200 ~2,600 To 500 100 167 500 500 to 600 74 123 370 Maximum Speed [mm/s] Note 5) Range 605 to 700 57 95 285 of Actuator specifications Storoke 705 to 800 45 75 225 [mm] 805 to 900 36 60 180

Note 2) Connector orientation can be changed by 180 2) Pull the screw (1) out of the housing (2). degrees depending on how to assemble the 3) On the bottom part of the terminal block (3), theres a housing (2) and the terminal block (3). cut-off part (9).

output and charged potential at each installation distance 6 Sensor output voltage [V] 5 4 Installation distance: 50mm 3 2 Installation distance: 10 mm 1 Installation distance: 25mm Installation distance: 25mm 0 -2000 -1500 -1000 -500 0 500 1000 1500 2000 Charged potential [V] Sensor head Installation Detection range distance (mm) (mm) Installation 10 45 distance 25 100 Detection port 50 180