Rated voltage 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 220 VAC 50/60 Hz [230 VAC 50/60 Hz] Electrical entry G H L LN LO M MN MO W0 Grommet (300 mm lead wire) Grommet (600 mm lead wire) With lead wire Without lead wire Without connector With lead wire Without lead wire Without connector Without connector cable Electrical
wire Without connector 50 60 2 200 VAC Hz M M plug connector 50 60 110 VAC Hz [115 VAC Hz] MN MO M8 connector Without connector cable W0 3 50 60 50 60 50 60 4 220 VAC Hz [230 VAC Hz] Note) For connector cable of M8 connector, refer to page 225.
motor (S3) 200 W AC servo motor (S2) 200 to 230 VAC 50/60 Hz AC servo motor (S4) 400 W AC servo motor (S3) Power supply voltage AC servo motor (S6) 100 W AC servo motor (S4) 1 2 100 to 120 VAC, 50/60 Hz 200 to 230 VAC, 50/60 Hz Absolute AC servo motor (S7) 200 W AC servo motor (S6) 100 to 120 VAC 50/60 Hz AC servo motor (S8) 400 W AC servo motor (S7) Pulse input type (For absolute encoder
N.O. 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz Note) N.O. valve operates properly only when appropriate pressure is applied to the pilot.
0 0 10 20 30 40 50 60 70 80 Vacuum pressure [kPa] 0 0 10 20 30 40 50 60 70 80 Vacuum pressure [kPa] ZP3E-50UM ZP3E-125UM 4 8 Displacement [mm] Displacement [mm] 3 6 2 4 N, S, U, F, CL N, S, U, F, CL 1 2 0 0 10 20 30 40 50 60 70 80 Vacuum pressure [kPa] 0 0 10 20 30 40 50 60 70 80 Vacuum pressure [kPa] ZP3E-63UM 6 Displacement [mm] 4 N, S, U, F, CL 2 0 0 10 20 30 40 50 60 70 80 Vacuum pressure
REA63 0 86 32 53 300.033 58.2 25 110 55 M8 x 1.25 x 16 176 M12 x 1.25 x 7.5 60 60 180 0 320.039 100 38 66 72.2 26 122 69 M10 x 1.5 x 16 188 M14 x 1.5 x 11.5 70 70 192 Mounting Nuts: 2 pcs.
(Displays 0 when the (Displays 0 when the (Displays 0 when the value is below 30 L/min) value is below 60 L/min) value is below 120 L/min) 60 to 3150 L/min 120 to 6300 L/min 240 to 12600 L/min 2.0 0 to 2%F.S.
65 70 75 80 115 140 45 50 55 60 65 70 75 80 85 120 145 30 35 40 45 50 55 60 65 70 75 30 35 40 45 50 55 60 65 70 75 110 135 M5 x 35 x 40 x 45 x 50 x 55 x 60 x 65 x 70 x 75 x 80 x 115 x 140 M6 x 45 x 50 x 55 x 60 x 65 x 70 x 75 x 80 x 85 x 120 x 145 M5 x 30 x 35 x 40 x 45 x 50 x 55 x 60 x 65 x 70 x 75 M5 x 30 x 35 x 40 x 45 x 50 x 55 x 60 x 65 x 70 x 75 x 110 x 135 M3 x 25 x 30 x 35 x 40 x
30 60 80 40 80 100 50 100 120 70 120 160 100 160 200 60 10 40 MHC 60 MHT 16 40 MHY 60 MHW 20 40 MRHQ 60 25 Misc. 40 30 D32 20 2030 40 P . 12-4-7 20 Note) The open and close time spans represent the value when the exterior of the workpiece is being held.
Dew point conversion chart 60 50 40 30 Pressure dew point C 20 10 1.5MPa 1.3MPa 1.1MPa 0.9MPa 0.7MPa 0.5MPa 0.3MPa 0.1MPa Atmospheric pressure 0 10 20 30 40 50 60 50 60 40 30 20 10 0 10 20 30 Atmospheric pressure dew point C 25 Series IDU/IDF Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.
MHL2-10D MHL2-16D MHL2-16D MHL2-10D 2 1 2 1 60 60 25 25 0.6MPa 0.6MPa Holding force (N) Holding force (N) Holding force (N) Holding force (N) 50 50 20 20 0.5MPa 0.6MPa 0.5MPa 0.6MPa 40 40 15 15 0.4MPa 0.5MPa 0.4MPa 0.5MPa 0.4MPa 0.4MPa 30 30 10 10 0.3MPa 20 20 0.3MPa 0.3MPa 0.3MPa 0.2MPa 5 5 10 10 0.2MPa 0.2MPa 0.2MPa 10 20 30 40 50 60 70 20 40 60 80 100 120 20 40 60 80 100 120 0 0 0 10 20
Nil E Yes Without light, with surge voltage suppressor Seal Metal seal Rubber seal 0 1 Coil voltage Function 1 2 3 Stations 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC D side U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) (2) Applicable to DC sepecifications.
) [Current mA] Note) DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Inrush Refer to pages 3-3-60 to 3-3-65 for manifold use.
DL B DA DC DDH10 (hole) DE DF DH DO DR DS DT DU DX Z CA2-B04 CA2-B05 CA2-B06 CA2-B08 CA2-B10 +0.058 0 60 57 65 85 52 40 35 10 9 8 17 11 15 234 10 +0.070 0 70 57 65 85 52 40 35 10 9 8 17 11 18 261 12 12 60 162 +0.070 0 85 67 80 105 66 50 40 12.5 11 10 22 13.5 25 280 16 80 100 +0.084 0 102 93 100 130 90 65 60 15 13.5 12 24 16.5 31.5 337 20 +0.084 0 116 93 100 130 90 65 60 15 13.5 12 24 16.5
: 6 x 4 nylon tubing Name plate and caution plate for bowl in imperial units (PSI, F) Applicable model AL30 to 60 AL30 to 60 AL30 to 60 AL10 to 60 AL10 to 60 AL10 to 60 AL30 to 60 AL20 AL10 to 60 AL30 to 60 AL10 to 60 F.R.L.
Nil E Yes Without light, with surge voltage suppressor Seal Metal seal Rubber seal 0 1 Coil voltage Function 1 2 3 Stations 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC D side U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) (2) Applicable to DC sepecifications.
25 30 35 40 50 60 55 65 Up to 300 Up to 300 Up to 500 Up to 600 Up to 600 Up to 750 Up to 750 Bore (mm) Pin part No.
to 60 AL20 AL10 to 60 AL30 to 60 AL10 to 60 Body size 10 20 30 40 50 60 Thread type Metric thread (M5) Rc NPT G Nil N F AL20 Port size Body size Symbol Port size M5 1/8 1/4 3/8 1/2 3/4 1 10 20 30 40 50 60 Note 2) M5 01 02 03 04 06 10 Accessory When more than one specification is required, indicate in alphanumeric order.
Static Neutralization Characteristics 1) Installation distance and discharge time (Discharge time from 1000 V to 100 V) High speed static neutralization cartridge Air purge: Yes Supply pressure: 0.02 MPa (1 L/min (ANR) per nozzle) Air purge: No 30 45 25 40 60 Hz 35 1 Hz Discharge time (s) Discharge time (s) 1 Hz 20 30 15 Hz 5 Hz 25 15 20 Sensing DC 10 15 Sensing DC 1 Hz/60 Hz 60 Hz 30 Hz
M12 x 1.25 M20 x 1.5 74 20 57 33 1/2 29 11 32 18 28 30 25 42 9 24 42 53 28 63 25 to 800 90 64.3 60 M12 x 1.25 M27 x 2 80 20 55 33 29 1/2 32 13 36 17 30 32 50 13 39 30 36 68 80 25 to 800 115 82.7 80 M16 x 1.5 M33 x 2 93 28 66 40 34 3/4 39 45 20 17 40 41 60 46 9 45 41 76 100 25 to 1000 130 96.9 100 M16 x 1.5 M42 x 2 101 36 67 40 3/4 50 20 19 54 56 50 52 72 47 10 50 91 56 Tolerances CD Bore