D-M9AL Bore size (mm) D A B C 6 10 15 20 25 32 19.5 0.5 7.5 11.5 A C 29.5 3 17.5 9 35.5 10 23.5 2 Electrical entry direction: Inward Electrical entry direction: Outward 43 13 31 5 44 15 32 7 53 15.5 41 7.5 Auto switch mounting dimensions (mm) CXSJ6,10 C3 10 Bore size B1 Symbol Auto switch model C2 D2 6 1 1 2 5.5 4 8 6 D1 D-A9 D-M9, D-M9W D-M9AL A1 B1 B1 C1, D1 C2, C3, D2 C1, D1 C2, C3, D2
x 0.7 M6 x1 M8 x1.25 M10 x1.5 1 1 1 1 1 1 1 1 38 55 72 100 20 22 32 40 4.5 5.5 6.5 9.0 10 12 16 19 6.0 9.5 11.0 14.0 Applicable cylinder Model Mounting direction q C1 D1 F1 K1 10 11 16 20 Q1 B1 A1 MYAJ16 MYAJ25 MYAJ40 MYAJ63 MY316 MY325 MY340 MY363 29.0 38.5 56.0 86 68 90 130 186 34 45 65 93 18 24 32 50 88 112 162 226 5.5 6.5 9.5 10.0 Applicable cylinder Model Mounting direction w B2 A2 C2
To the communication connector (C2) or (1) of SI unit, connect the branch cable with M12 connector from GW. To the communication connector (C1) or (0), connect the branch cable with M12 connector from Input unit. To the communication connector of Input unit, connect the branch cable with M12 connector from SI unit.
Note 5 Lock pin ZK2-CL1-A 5 pcs. in 1 set 6 Check valve ZK2-CV-A 10 pcs. in 1 set 8 Pad ZP3E-[][][] Flat / Bellows type with groove 9 Plate ZHP1-PL[]-A 10 Holder TB00148 Included for metric size 11 Plug *1) TB00055 Included for inch size 12 One-touch fitting KJH[]-C2 13 Ejector assembly ZK2-EJ[]W-A 14 Silencer assembly ZHP1-SA1-A 15 Lock screw CA00284 Included 1) 3 pieces are included in
Max. operating pressure differential (MPa) Orifice size (mm ) VX2 Model Voltage Type Pressure port 1 Pressure port 2 Note) 1 2 3 4 5 6 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC VX C1 C2 10, 20, 30 200, 300 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.9 0.4
(485) 463 IDF70 890 (Air dryer outside) 849 (Air dryer outside) 365 390 IDF60/70/80/90 Series 7.3 Dimensions 7-3 IDX-OM-V022 Chapter 7 Documents 7.4 Electric circuit IDF60/70 200/200,220VAC 1PH 50/60Hz SYMBOL DESCRIPTION CM Refrigerating compressor OLR Overload relay FM Fan motor MC Magnetic contactor PRS High pressure switch PRS2 Pressure switch ILS Switch with lamp THR Thermal relay C01
Weight [g] JXC-C2-1 160 JXC-C2-3 300 JXC-C2-5 480 DIN rail L For 3 Axes For 4 Axes 5.25 12.5 (Pitch) JXC92 JXC73/83/93 7.5 AXT100 DR * For , enter a number from the No. line in the table below.
Actuating solenoid valve electric signal Valve opening O After a few seconds at 10-6Torr 90% 100% 90% Valve closing Operation time Responce time Conductances combined When each of the separate conductances are given as C1, C2 and Cn, the composite conductance C is expressed as: C=1/(1/C1+1/C2+...1/Cn) when in series, and C=C1+C2+...Cn, when in parallel. 39 Series XL Technical Data 5 He leakage
With External Pilot Specifications (Pitch) P=16 17.5 48 23.5 11.8 18.8 9.5 12.5 SJ 15.9 29.2 31.5 34.6 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A E 3/5 E 3/5 SY 52.7 53.9 E 3/5 E 3/5 67.5 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B C2 C2 P 1 P 1 P 1 P 1 SV PE PE X X C1 C1 2 x M12 SYJ One-touch fitting [X: External pilot port] Applicable tubing O.D.: 4 5/32" One-touch fitting [PE: Pilot EXH port]
Confirm S dimension and solenoid dimensions. 1569 Series CVM5 Head Side Flange Style (G) CVM5G Bore size Stroke Max. 21 Min. 18 x Mounting hole Width across flats B2 Manual override Width across flats B1 Width across flats NA x In the case of 40 Mounting hole S + Stroke Z + Stroke ZZ + Stroke In the case of 20 to 32 (mm) HX H2 H1 H FZ FY FX FT FD F D Eh8 C2 B2 B1 B AL A Stroke range Bore
Applicable bore size B2 C2 d H2 SNJ-010C 10 11 12.7 M8 x 1.0 4 NTJ-010C 10 7 8.1 M4 x 0.7 3.2 Y-J016C 16 11 16.6 21 M5 x 0.8 SNJ-016C 16 14 16.2 M10 x 1.0 4 Part no. NDd9 NDH10 NX R1 U1 Y-J010C 3.30.030 0.060 3.3+0.048 0 3.2 8 10 NTJ-015C 16 8 9.2 M5 x 0.8 4 Y-J016C 50.030 0.060 5+0.048 0 6.5 12 10 * A knuckle pin and retaining rings are included.
A CSV-101 2 Hand AntiTie Down Control Unit CSV-101 LS Same as above, but with low stress buttons CSV 107 LS1 Same as CSV-101, but w/ remote buttons CSV 107 LS2 Same as above but/ with low force actuators B MV-35 Two Position Detented 3-Way Valve MV-TP Two Position Detented 3-Way Valve C C2-2H Three Position Spring Centered 4-Way Valve www.poweraire.com 1-800-526-7661 23 Section III: Circuits
A CSV-101 2 Hand AntiTie Down Control Unit CSV-101 LS Same as above, but with low stress buttons CSV 107 LS1 Same as CSV-101, but w/ remote buttons CSV 107 LS2 Same as above but/ with low force actuators B MV-35 Two Position Detented 3-Way Valve MV-TP Two Position Detented 3-Way Valve C C2-2H Three Position Spring Centered 4-Way Valve www.poweraire.com 1-800-526-7661 23 Section III: Circuits
2 One-touch fitting 2-position SY331-C2 C2 2 One-touch fitting 3-position 98 SY330-C2 3-position 95 87 97 2-position C3 3.2 One-touch fitting 4-position 91 85 94 Metal seal SY331-C3 2-position 3-position 101 C3 3.2 One-touch fitting Rubber seal SY330-C3 3-position 79 89 98 2-position C4 4 One-touch fitting SY331-C4 4-position 94 77 86 3-position 93 2-position C4 4 One-touch fitting 82 92
1 I/O cable length [m]*3 Compatible driver Power supply voltage [V] Size 25 32 40 Nil Without driver A1 LECSA1-S100 to 120 A2 LECSA2-S200 to 230 B1 LECSB1-S100 to 120 B2 LECSB2-S200 to 230 C1 LECSC1-S100 to 120 C2 LECSC2-S200 to 230 S1 LECSS1-S100 to 120 S2 LECSS2-S200 to 230 *3 When Without driver is selected for driver type, only Nil: Without cable can be selected.
Applicable shaft types: J, X, Z d1 = d1 = d1 = d1 = L2 = Y = C2 J axis X axis D2 = C2 = C K axis T axis (mm) (mm) (mm) d1 Size 30 50 63 80 100 d1 Size 30 50 63 80 100 Y 3 to 25 1 to 36 1 to 41 1 to 50 1 to 60 L2 max Y 2 Y Y Y Y D2 5 to 7.9 5 to 14.9 5 to 16.9 8 to 19.9 8 to 24.9 Size 30 50 63 80 100 2.5 4 to 7.5 4 to 8 6.8 to 11 6.8 to 13 2.5 4 to 7.5 4 to 8 6.8 to 11 6.8 to 13 11-7
Applicable shaft types: J, X, Z d1 = d1 = d1 = d1 = L2 = Y = C2 J axis X axis D2 = C2 = C K axis T axis (mm) (mm) (mm) d1 Size 30 50 63 80 100 d1 Size 30 50 63 80 100 L2 max Y 2 Y Y Y Y Y 3 to 25 1 to 36 1 to 41 1 to 50 1 to 60 D2 5 to 7.9 5 to 14.9 5 to 16.9 8 to 19.9 8 to 24.9 Size 30 50 63 80 100 2.5 4 to 7.5 4 to 8 6.8 to 11 6.8 to 13 2.5 4 to 7.5 4 to 8 6.8 to 11 6.8 to 13 11-7
Actuating solenoid valve electric signal Valve opening O After a few seconds at 10-6Torr 90% 100% 90% Valve closing Operation time Responce time Conductances combined When each of the separate conductances are given as C1, C2 and Cn, the composite conductance C is expressed as: C=1/(1/C1+1/C2+...1/Cn) when in series, and C=C1+C2+...Cn, when in parallel. 39 Series XL Technical Data 5 He leakage
Application Application Mounting direction w (to minimize the installation width) Work piece Mounting direction q (to minimize the installation height) Work piece Guide Guide Series MY3 Series MY3 Floating mechanism Bracket Floating mechanism Bracket Mounting Example Mounting Example G G D1 D2 Za2 Za1 Ea Ea Ea Ea C1 C2 K2 (Screw length) B2 F2 B1 F1 K1 (Screw length) Detail drawing of Za2
No.SFOD-OMT0009CN-B 2. 2.1 , 4 4 / 3 2 (SETUP)1 512 2048 I/O 1 4 USB , 7 No.SFOD-OMT0009CN-B 2.2 J X C *3 I/O 1) I/O 1 1.5m 2 1.5m DIN 7 NPN 3 3m 8 PNP 4 3m DIN 4 5 5m 6 5m DIN 7 8 DIN 1)I/O (1.5m~5m) I/O 2 LEY Series LEYG Series LEF Series LES/LESH Series 2) LER Series LEPY/LEPS Series 2 3 LEH Series 2) 360 8 No.SFOD-OMT0009CN-B 2.3 1) PLC I/O 2) :JXC-C2